Material Hoist
Vertical Access Equipment, Material Lifting Equipment, Construction Elevator, Industrial Hoist
Most of the material hoists are driven by steel wire rope winch. The safety device on cage are broken rope protectors, which are available in various types on market, but few can continuously work safely after several years’ service. Consumers with strong safety demand raise the requirement to set an R&P safety device on the material hoists.
BAODA has specially developed the rack & pinion type material hoist according to this requirement. All driving mechanism: safety device, mast section (650x650mm) and wall tie which can be interchangeable with normal passenger/material R&P hoist. There’s a visual indicator in case there’s any person in cages or the door for unloading materials is locked. The hoist will be in absolute safety under these assurance. The maximum lifting height is 100m. This material hoist is suitable for transport of materials in multi-layer and high-rise buildings. It takes less space and has complete safety and protection devices, and may set guidance for the development of future material hoists.
Technical Parameters of SC100H&SC100H/100 Material HoistModel Parameters | SC100H | |||
Each cage | Rated load (㎏/person) | 1000/14 | ||
Rated installation load (㎏) | 1000 | |||
Rated load of installation crane (㎏) | 150 | |||
Internal size of the cage L×W×H (m) | 3.2X1.5X2.0 | |||
Maximum lifting height, tied mast (m) | 95 | |||
Maximum lifting height, untied mast (m) | 7 | |||
Rated lifting speed (m/min) | 28 | |||
Power for each cage | Supply voltage / frequency | 380~460V/50~60Hz (three phase) | ||
Power-drive unit (S3,25%),(kW) | 14.5X1 | |||
Braking (N.m) | 170×2 | |||
Control voltage / frequency | 110V, 220V/50Hz, 60Hz ( or according to user's need) | |||
Each cage | Maximum starting current (A) | 150 | ||
Minimum power supply (kVA) | 20 | |||
Safety device | Model | SAJ30-1.0 | ||
Tripping speed (m/s) | 0.75 | |||
Column center distance of mast (m) | 0.65×0.65, height of 1.508 | |||
Weight of each counterweight (㎏) | ─ | |||
Weight of each cage (㎏) (drive mechanism included) | 980 | |||
Power of inverter (kW) | ─ | |||
Height from the ground to the cage floor at the base level (m) | 1.0 |