Oil and Gas Fired Thermal Oil Boiler

Oil and Gas Fired Thermal Oil Boiler
Oil and Gas Fired Thermal Oil Boiler
Oil and Gas Fired Thermal Oil Boiler
Oil and Gas Fired Thermal Oil Boiler
Oil and Gas Fired Thermal Oil Boiler
Request a Quote

Heating capacity : (30-1500)×104kCal/h
Designed pressure: 1.1MPa
Maximum working temperature: 320℃
Fuel type: diesel oil, natural gas and city gas.

Application

This boiler uses diesel oil or natural gas as fuel in the thermal oil heat carrier. The boiler is designed for use in low pressure, high temperature environments, providing a highly efficient heat energy. We can design this boiler in a horizontal or vertical design, as well as a gas fired thermal oil boiler, all based on customer requirements. If designed in a vertical structure, compared to the horizontal design, installation is easier, faster, and covers less area. These oil and gas fired boilers are then used in petrochemical plants, grease processing plants, building materials processing plants, chemical plants, textile processing plants, food processing plants, plastic and rubber processing plants, pharmaceutical plants, paper plants and bitumen plants.

Technical parameters:
Type Rated power ( KW ) Heating capacity× 104 ( kCal/h ) Thermal efficiency( % ) Designed pressure ( MPa ) Maximum working temperature (℃) Medium circulation flow( m3/h ) Medium capacity in boiler ( m3 ) Main tube diameter ( DN ) Installed capacity ( kW ) Fuel consumption Kg/h (calculated by oil) dimension
Vertical horizontal
YYL(W)-350Y 350 30 ≥ 88 1.1 320 40 0.4 100 14.5 34 1.3 × 2.5 1.2 × 2.4
YYL(W)-600Y 600 50 ≥ 88 1.1 320 58 0.6 100 18 56 2 × 3.5 1.7 × 3
YYL(W)-900Y 900 75 ≥ 88 1.1 320 100 0.6 125 31 84 2.1 × 3.5 1.82 × 3.5
YYL(W)-1200Y 1200 100 ≥ 88 1.1 320 100 0.8 125 37.5 111 2.2 × 3.5 1.92 × 4
YYL(W)-1500Y 1500 130 ≥ 90 1.1 320 100 1.2 125 49.5 141 2.2 × 4 1.95 × 4.3
YYL(W)-1800Y 1800 150 ≥ 90 1.1 320 160 2.1 150 57.5 163 2.4 × 4.4 2.4 × 4.3
YYL(W)-2300Y 2300 200 ≥ 90 1.1 320 160 2.6 150 61.5 217 2.7 × 5.1 2.52 × 5.3
YYL(W)-2900Y 2900 250 ≥ 90 1.1 320 200 3.5 200 75 273 2.8 × 6.5 2.8 × 6.3
YYL(W)-3500Y 3500 300 ≥ 90 1.1 320 200 7.8 200 75 326 3.2 × 6.7 2.92 × 6
YYL(W)-4700Y 4700 400 ≥ 90 1.1 320 260 8.4 200 98.5 435 3.2 × 7 3.23 × 6.7
YYL(W)-5900Y 5900 500 ≥ 90 1.1 320 300 8.8 250 121.5 545 3.3 × 7.5 3.26 × 7.45
YYL(W)-7000Y 7000 600 ≥ 90 1.1 320 340 10.5 250 148.5 660 3.5 × 8.2 3.26 × 7.9
YYL(W)-8200Y 8200 700 ≥ 90 1.1 320 400 11.2 250 155 760 3.62 × 9.2 3.62 × 9
YYL(W)-9400Y 9400 800 ≥ 90 1.1 320 520 11.5 300 195 875 3.7 × 9.6 3.6 × 9.48
YYL(W)-10500Y 10500 900 ≥ 90 1.1 320 600 13 300 235 980 3.65 × 11 3.65 × 10.4
YYL(W)-12000Y 12000 1000 ≥ 90 1.1 320 600 15 300 235 1140 3.65 × 11 3.65 × 10.6
YYL(W)-14000Y 14000 1200 ≥ 90 1.1 320 680 18 350 295 1360 3.98 × 11.8 3.98 × 11.5
YYL(W)-15000Y 15000 1300 ≥ 90 1.1 320 800 21 350 341 1460 4 × 12.5 4 × 12.2
YYL(W)-16300Y 16300 1400 ≥ 90 1.1
800 23 350 341 1600 4.06 × 12.8 4.06 × 12.5
Manufacturing process features

The vertical coal fired boiler features complex processing links, and utilizes fine processing, which is an important factor in final product quality and safe usage by the customer.

1. Boiler material: seamless steel pipe
2. Welding process: Argon arc welding and radiographic testing
3. Bending shaping: The tube is shaped after the bending process in the pipe bending machine in order to ensure the coil outline dimension accuracy and ensure it meets GB/T17410 standards.
4. Water pressure testing: After shaping, the water pressure test for the tube is carried out before the boiler leaves the factory.

Features

1. Protection function
· Automatically alarm when the liquid level inside the expansion tank is too low.
· Automatically alarm when the thermal oil outlet pressure exceeds rated pressure
· Automatically alarm when the thermal oil temperature is too high
· The system will automatically stop, and sends out an acousto-optic alarm signal if there are any abnormal conditions, such as a shutdown of the circulating pump.

2. Automatic detection function
· The control system can automatically detect pressure and temperature of the heat medium.
· The control system can automatically detect the outlet temperature of the heat medium, and maintain it within the pre-set range.

Related products
Send Message
Other Products
Inquiry
Inquiry