Vacuum Drying Furnace
Request a Quote
Vacuum Drying Furnace
This vacuum drying furnace adopts variable-pressure drying principle suggested by Dr. Moll from Germany, which is specialized for drying transformer bodies. Compared with conventional vacuum heating drying methods, the variable pressure type can save up to 30-45% drying duration.
Main Features
- Compact structure, small size
- Heating system is controlled by power control module, ensuring even and stable temperature. Real power consumption during temperature-keeping is only about 35% of total power. There is no fluctuation of heating load and thus greatly reduces actual heating power.
- PLC control, more stable and reliable
- Special baffle valves for vacuum drying, better vacuuming performance
Technical Data
Vacuum drying autoclave
- Effective inner dimension5000 x 3000 x 3500mm (L x W x H)
- Ultimate vacuity< 50Pa (idle, cold)
- Leakage of autoclave< 300Pa·L/S
- Max. heating temperature130℃
- Temperature evenness inside±2℃
- Max. loading capacity50T
- Temperature sensor3 units
Vacuum system
- Ultimate vacuity< 10Pa (idle, cold)
- Max. extracting speed900L/S
- SV-300 rotary vacuum pump1 unit
- ZJ900 Roots pump1 unit
- Heating power96kW
- Heating mediaHeat induction oil
Control system
- Temperature displaying meter3 units
- Temperature control meter1 unit
- Vacuum transmitter1 unit
- PLC HMISiemens