Industrial Cable Manufacturer

Industrial Cable Manufacturer
Request a Quote
Structure of Stranded Loose Tube Air Blown Fiber Cable
  • Optical fiber
  • Optical gel: water-proof compounding
  • Buffer tuber: thermoplastic material
  • Center strength member: fiber reinforced plastics, high-count fiber cable and extruded polyethylene.
  • Water blocking material: water-proof compounding
  • Winding
  • Outer jacket: black polyethylene
Parameter
1. Technical parameter
Item Content Value
Number of cable cores 24 48 96 144 288
Loose tube Number of Loose Tube* number of cores per tube* 2*12 4*12 8*12 12*12 24*12
Outer diameter(mm) 1.55 1.55 1.55 1.55 1.55
Reference outer diameter mm 5.5 5.5 6.5 8.5 10.0
Central strength member Material FRP
Water blocking material Material Water blocking cable gel
Outer jacket Thickness(0.1mm) 1.8
Range of operating temperature -40- +70
Pull Short-term/long-term(G) 0.5/0.15
Flatten Short-term/long-term(N) 450/150
*According to customers requirements, the stranded loose tube armored cable can customize other structures or cores. G is the weight of 1KM micro-cable, the unit is Newton. (N)G1KM(N)
2. Characteristic of optical fiber
G.652.D G.655 50/125m 62.5/125m
Attenuation @850nm - - 3.0dB/km 3.0dB/km
@1300nm - - 1.0dB/km 1.0dB/km
@1310nm 0.36dB/km 0.36dB/km - -
@1550nm 0.22dB/km 0.23dB/km - -
Band width @850nm - - 500MHzkm 200MHzkm
@1300nm - - 1000MHzkm 600MHzkm
Fiber cutoff wavelength 1260nm 1260nm - -
Polarization Mode Dispersion Single optical fiber 0.20ps/km 0.20ps/km - -
Link value(M=20Q=0.01%) 0.10ps/km 0.10ps/km - -
3. Main machinery and environment performance
Item Inspection standard Specified value Requirements
Pull IEC 60794-1-2-E1 According to technical parameter Additional attenuation for short term:0.1dB
Flatten IEC 60794-1-2-E3 According to technical parameter Additional attenuation for short term:0.1dB
Impact IEC 60794-1-2-E4 The height is 1 meter punch hammer 450g, at least 5 times1 450g 5 Additional attenuation for short term:0.03dB
Backward and forward bending IEC 60794-1-2-E6 Loading 150N 30 times Residual additional attenuation:0.03dB
Twisting IEC 60794-1-2-E7 1 180 10 Residual additional attenuation:0.03dB
Temperature recycle test IEC 60794-1-2-F1 -40 +70 Change of additional attenuation0.05dB/km
* The monitoring of all optical fiber attenuations change is operated in wavelength of 1550nm.
Features
  • The technology in the air blown fiber cable is designed to minimize the size and specification of cables and pipelines by optimizing the material, craft and structure of cable and pipeline. The installation of air blown fiber cable is air-blowing to meet the technology of maximizing the use of pipelines space.
  • Combined with micro-pipeline, the air blown fiber cable can contain five micro-pipes with a specification of 10/8 (outer diameter/inner diameter) in regular main-pipeline with specification of 40/33. So, it can improve the utilization efficiency of pore.
  • The outer diameter of cable is smaller than 10.5mm. The micro-cable with same number of cores is more than one times smaller than the regular cable. The stranded loose tube air blown fiber cable can be laid by air-blowing in micro-cable of corresponding specifications.