The ERMS series UPS system is composed of a monitoring module and multiple 6kVA power modules. This is a type of rack-mounted UPS and could be embedded into a standard 19 inch cabinet or working individual for decentralized power supplying. Sicon provides 3 power module models: ERMS-12/6, ERMS-24/6 and ERMS-36/6, and their maximum power capacities are 12kVA, 24kVA and 36kVA.

ERMS-12/6 UPS System
  • Maximum power: 12kVA
  • Could be embedded into standard 19 inch cabinet
  • Power module model: ERM-06
  • Module power: 6kVA
  • Weight: Approximate 12kg 2*7kg (each module)
  • Dimension: 480*600*132 mm (W*D*H)
  • Weight: 12kg
ERMS-24/6 UPS System
  • Maximum power: 24kVA
  • Could be embedded into standard 19 inch cabinet
  • Power module model: ERM-06
  • Module power: 6kVA
  • Weight: Approximate 16kg 4*7kg (each module)
  • Dimension: 480*600*220 mm (W*D*H)
  • Weight: 16kg
ERMS-36/6 UPS System
  • Maximum power: 36kVA
  • Could be embedded into standard 19 inch cabinet
  • Power module model: ERM-06
  • Module power: 6kVA
  • Weight: Approximate 20kg 6*7kg (each module)
  • Dimension: 480*600*310 mm (W*D*H)
  • Weight: 20kg
UPS System Technical Parameters
Module
Module model ERM-06
Module power 6kVA
Input/output 1/1 phase
Module dimension (W×D×H)mm 220×500×85
Weight (kg) Approximate 7kg
Module charging Each module provides 1A charging current
Input power factor ≥ 0.99
Overload ability Exceeds system overload requirements
Maximum heat dissipation power 340W
THDI (%) ≤ 3%
Mains Input
Input mode 3-phase N E, 1-phase N E
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50Hz±10%, 60Hz±10%
Power woke-in (Sec.) 60sec
THDI (%) <3%
Input PF ≥0.99
Bypass Input
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50 Hz, 60 Hz
Range of Frequency Synchro 50 Hz±4%, 60 Hz±4%
DC Input
Rated Input voltage ±240VDC
Input voltage tolerance ±216V~±246V DC
Battery charging
Charging current limited yes
Charging ability 10 hours (2 hours back up)
Stability of charging voltage ±1%
AC output
UPS power factor 0.9
Output voltage 380V/220V AC, 400V/230V AC, 415V/240V AC
Output frequency ±4%;±0.2% (battery supply)
Output voltage stability ±1%
Output voltage recovering time <20ms (load 0~100% change)
Overload ability Operate 10mins with 125% load
Transfer from mains to battery supply 0ms
Transfer from bypass to inverter supply < 1ms
Peak factor 3:1
Waveform distortion ≤1% ( linear load ), ≤3%( non-linear load )
Overall efficiency ≥95% (AC~AC), ≥98% (DC~AC)
Load share precision ≤5%
Operation environment
Ambient temperature -25℃~60℃
Operating temperature -5℃~40℃
Maximum operation altitude ≤1500m
Relative humidity ≤95% non-cadency
Protection degree IP30
Cooling Air cooling
Applicable safety standards EN62040-1-1:2003 IEC60950-1:2001
Electromagnetic compatibility EN62040-2:2006
Acoustic noise ≤55DB
Others
Cabinet Standard 19 inch cabinet
Monitor management system UPSupervisor
Interface RS232, RS485, 2 try contact, TCP/IP adapter
Display LCD/LED