WARM produces solar-powered air conditioner and hybrid solar air conditioners. The solar-powered air conditioner uses PV solar panels to generate electricity and store it in a battery without connecting to a grid. This air conditioner works continuously for 10 hours, making it highly applicable to areas with an insufficient electricity supply and sufficient lighting. The hybrid storage air conditioner does not need a storage battery, as it uses solar power first, and if there is not enough solar power, it will connect to the grid for a power source, making it a more flexible option.

The solar air conditioner saves electricity consumption costs, because solar power replaces electricity. IN remote areas and areas with an inefficient energy supply, this is an ideal solution, as it works even during a power cut.


Parameter of solar powered air conditioner (cold only)

Model HSAC-09C/PA HSAC-12C/PA HSAC-18C/PA HSAC-24C/PA
Power supply DC 48V DC 48V DC 48V DC 48V
Cooling Capacity Btu/h 9000 (4200~11000) 12000 (3700~14000) 18000 (6200~20000) 24000 (9000~25000)
Input Power W 475 (80~950) 635 (100~1230) 920 (150~1450) 1310 (250~1600)
Rated current A 9.9 (1.66~19.79) 13.2 (2.08~25.6) 19.2 (3.13~30.21) 27.3 (5.21~33.33)
Heating Capacity Btu/h 9500 (3500~11500) 13000 (3700~14500) 18500 (6200~21000) 25000 (9000~26000)
Input Power W 462 (100~950) 620 (120~1280) 940 (180~1500) 1285 (280~1650)
Rated current A 9.6 (2.08~20.41) 12.9 (2.5~26.66) 19.6 (3.75~31.25) 26.8 (5.83~34.38)
Moisture Removal Volume L/h 1 1.3 1.7 2.5
Max. Input Power W 1050 1200 1500 1800
Max. Current A 21.87 25 31.25 37.5
Indoor airflow (Hi/Mi/Lo) m3/h 570/470/370 570/470/370 721/566/458 970/780/590
Indoor noise level (Hi/Mi/Lo) dB(A) 41/36/28/23 41/36/28/23 43/39/35 ≤45/36/31
Indoor unit Dimension(W*D*H) mm 805*194*285 805*194*285 957*213*302 1040*220*327
Packing (W*D*H) mm 870*270*360 870*270*360 1035*305*380 1120*310*405
Net/Gross weight Kgs 7.2/9.6 7.2/9.6 9.5/12.5 11.9/15.2
Outdoor noise level dB(A) ≤50 ≤50 ≤52 ≤56
Outdoor unit Dimension (W*D*H) mm 835*320*540 835*320*540 835*320*540 910*340*700
Packing (W*D*H) mm 890*400*600 890*400*600 890*400*600 1063*480*760
Net/Gross weight Kgs 33/39 35/40 39/44 56/62
Refrigerant Pipe Size inch 3/8", 1/4" 3/8", 1/4" 1/2", 1/4" 5/8", 3/8"
Application area m2 12~18 16-23 24-35 32-47
Container Stuffing sets 93/186/226 93/186/226 83/166/202 52/104/128

Parameter of hybrid solar air conditioner (cold only)

Model HSAC-09H/PA HSAC-12H/PA HSAC-18H/PA HSAC-24H/PA
Power supply DC 48V DC 48V DC 48V DC 48V
Cooling Capacity Btu/h 9000 (4200~11000) 12000 (3700~14000) 18000 (6200~20000) 24000 (9000~25000)
Input Power W 475 (80~950) 635 (100~1230) 920 (150~1450) 1310 (250~1600)
Rated current A 9.9 (1.66~19.79) 13.2 (2.08~25.6) 19.2 (3.13~30.21) 27.3 (5.21~33.33)
Heating Capacity Btu/h 9500 (3500~11500) 13000 (3700~14500) 18500 (6200~21000) 25000 (9000~26000)
Input Power W 462 (100~950) 620 (120~1280) 940 (180~1500) 1285 (280~1650)
Rated current A 9.6 (2.08~20.41) 12.9 (2.5~26.66) 19.6 (3.75~31.25) 26.8 (5.83~34.38)
Moisture Removal Volume L/h 1 1.3 1.7 2.5
Max. Input Power W 1050 1200 1500 1800
Max. Current A 21.87 25 31.25 37.5
Indoor airflow (Hi/Mi/Lo) m3/h 570/470/370 570/470/370 721/566/458 970/780/590
Indoor noise level (Hi/Mi/Lo) dB(A) 41/36/28/23 41/36/28/23 43/39/35 ≤45/36/31
Indoor unit Dimension(W*D*H) mm 805*194*285 805*194*285 957*213*302 1040*220*327
Packing (W*D*H) mm 870*270*360 870*270*360 1035*305*380 1120*310*405
Net/Gross weight Kgs 7.2/9.6 7.2/9.6 9.5/12.5 11.9/15.2
Outdoor noise level dB(A) ≤50 ≤50 ≤52 ≤56
Outdoor unit Dimension (W*D*H) mm 835*320*540 835*320*540 835*320*540 910*340*700
Packing (W*D*H) mm 890*400*600 890*400*600 890*400*600 1063*480*760
Net/Gross weight Kgs 33/39 35/40 39/44 56/62
Refrigerant Pipe Size inch 3/8", 1/4" 3/8", 1/4" 1/2", 1/4" 5/8", 3/8"
Application area m2 12~18 16-23 24-35 32-47
Container Stuffing sets 93/186/226 93/186/226 83/166/202 52/104/128

Parameter of hybrid solar air conditioner (cold &hot)

Model HSAC-09C/HA HSAC-12C/HA HSAC-18C/HA HSAC-24C/HA
Power supply AC 230V/50~60Hz/1Ph 230V/50~60Hz/1Ph 230V/50~60Hz/1Ph 230V/50~60Hz/1Ph
DC DC 50~380V DC 50~380V DC 50~380V DC 50~380V
Cooling Capacity Btu/h 9000 (4200~13000) 12000 (4400~15200) 18000 (6200~19500) 24000 (5110~26900)
Input Power W 100~1270 100~1710 140~1800 240~3030
Rated current A 0.4~5.5 0.4~7.4 0.6~8.18 1.0~13.2
Heating Capacity Btu/h 1000 (2900~12700) 13000 (4100~16600) 19000 (4700~20000) 25000 (5500~30000)
Input Power W 130~1330 180~1740 200~1900 280~3140
Rated current A 0.6~5.8 0.8~7.6 0.9~8.63 1.1~13.7
Moisture Removal Volume L/h 1 1.3 1.7 2.5
Max. Input Power W 1320 1500 2300 3200
Max. Current A 6 7.5 10.45 14.54
Indoor unit Dimension(W*D*H) mm 805*194*285 805*194*285 957*213*302 1040*220*327
Packing (W*D*H) mm 870*270*360 870*270*360 1035*305*380 1120*310*405
Net/Gross weight Kgs 7.2/9.6 7.2/9.6 9.5/12.5 11.9/15.2
Airflow (Hi/Mi/Lo) m3/h 570/470/370 570/470/370 721/566/458 970/780/590
Noise level (Hi/Mi/Lo) dB(A) 41/36/28/23 41/36/28/23 43/39/35 45/36/31
Outdoor unit Dimension (W*D*H) mm 835*320*540 835*320*540 835*320*540 910*340*700
Packing (W*D*H) mm 900*400*600 900*400*600 900*400*600 1063*480*760
Net/Gross weight Kgs 33/39 35/40 39/44 56/62
Noise level dB(A) ≤50 ≤50 ≤52 ≤56
Refrigerant Pipe Size inch 3/8", 1/4" 3/8", 1/4" 1/2", 1/4" 5/8", 3/8"
Application area m2 12~18 16-23 24-35 32-47
Container Stuffing sets 93/186/226 93/186/226 83/166/202 52/104/128

Parameter of hybrid solar air conditioner (cold &hot)

Model HSAC-09H/HA HSAC-12H/HA HSAC-18H/HA HSAC-24H/HA
Power supply AC 230V/50~60Hz/1Ph 230V/50~60Hz/1Ph 230V/50~60Hz/1Ph 230V/50~60Hz/1Ph
DC DC 50~380V DC 50~380V DC 50~380V DC 50~380V
Cooling Capacity Btu/h 9000 (4200~13000) 12000 (4400~15200) 18000 (6200~19500) 24000 (5110~26900)
Input Power W 100~1270 100~1710 140~1800 240~3030
Rated current A 0.4~5.5 0.4~7.4 0.6~8.18 1.0~13.2
Heating Capacity Btu/h 1000 (2900~12700) 13000 (4100~16600) 19000 (4700~20000) 25000 (5500~30000)
Input Power W 130~1330 180~1740 200~1900 280~3140
Rated current A 0.6~5.8 0.8~7.6 0.9~8.63 1.1~13.7
Moisture Removal Volume L/h 1 1.3 1.7 2.5
Max. Input Power W 1320 1500 2300 3200
Max. Current A 6 7.5 10.45 14.54
Indoor unit Dimension(W*D*H) mm 805*194*285 805*194*285 957*213*302 1040*220*327
Packing (W*D*H) mm 870*270*360 870*270*360 1035*305*380 1120*310*405
Net/Gross weight Kgs 7.2/9.6 7.2/9.6 9.5/12.5 11.9/15.2
Airflow (Hi/Mi/Lo) m3/h 570/470/370 570/470/370 721/566/458 970/780/590
Noise level (Hi/Mi/Lo) dB(A) 41/36/28/23 41/36/28/23 43/39/35 45/36/31
Outdoor unit Dimension (W*D*H) mm 835*320*540 835*320*540 835*320*540 910*340*700
Packing (W*D*H) mm 900*400*600 900*400*600 900*400*600 1063*480*760
Net/Gross weight Kgs 33/39 35/40 39/44 56/62
Noise level dB(A) ≤50 ≤50 ≤52 ≤56
Refrigerant Pipe Size inch 3/8", 1/4" 3/8", 1/4" 1/2", 1/4" 5/8", 3/8"
Application area m2 12~18 16-23 24-35 32-47
Container Stuffing sets 93/186/226 93/186/226 83/166/202 52/104/128

Above-mentioned are 4 types of solar air conditioner, due to the small power, the 4 types of solar air conditioners are widely used in family or office building. If you need powerful air conditioner with higher cooling efficiency, we could provide direct evaporative cooling system, rooftop mounted HVAC unit, modular commercial HVAC system and cooling tower evaporative cooling system. If you need, please .