Ultrasonic Level Transmitter
The ultrasonic level transmitter is a kind of digital level measuring instrument controlled by microprocessor. Based on non-contact measuring principle, it is compatible with almost all types of mediums. If you are looking for a level measurement solution for liquid and solid materials, the ultrasonic level transmitter is your best choice.
Our HGUL series ultrasonic level meter is available in two-wire, three-wire and four-wire versions.
Two-wire ultrasonic level transmitter: power supply system and signal output system share the two wires
Three-wire ultrasonic level transmitter: independent power supply loop and signal output loop. When powered by 24VDC system, a 3-core cable can be used, and the negative terminals of power supply system and signal output system will share the same cable core.
Four-wire ultrasonic level transmitter: When powered by 220VAC system or by 24VDC system with completely isolated power supply loop and signal output loop, a 4-core cable shall be used. Whether it is DC or AC power supply, the output is 4~20mADC. High and low switch-outputs are available.
Measuring Range: 0-50m
The ultrasonic level transmitter is built for challenging corrosive mediums and various chemicals. The highly accurate sensor is controlled by PLC system and supports 4-20mA signal output.
Model SelectionTechnical Specifications of Ultrasonic Level Transmitters
1. Integrate Type
Measuring range (meter) | 0.2-4, 0.25-6, 0.3-8, 0.4-10, 0.6-15, 1.2-20, 1.4-30, 1.6-40 | 0.2-4, 0.25-6, 0.3-8, 0.4-10, 0.6-15, 1.2-20, 1.4-30, 1.6-40 | 0.2-4, 0.4-4, 0.3-8, 0.45-8 |
Accuracy | 0.2%FS | 0.2%FS | 0.2%FS |
Current output | 4-20mA | 4-20mA | 4-20mA |
Output load | 0-500Ω | 0-500Ω | 0-600Ω |
Display | LCD 4-digit | LCD 4-digit | LCD 4-digit |
Power supply | DC20-32V ≥30mA | DC20-32V ≥30mA | DC21-27V ≥35mA |
Temperature Compensation | Whole-range compensation | Whole-range compensation | Whole-range compensation |
Media Temp. | -45 ℃ ~ 85 ℃ | -45 ℃ ~ 85 ℃ | -20 ℃ ~ 75 ℃ |
Pressure range | ±0.1Mpa | ±0.1Mpa | ±0.1Mpa |
Beam Angle | 8°, 5°(3db) | 8°, 5°(3db) | 8°(3db) |
Measure cycle | 1 second | 1 second | 1 ~ 20 seconds |
Parameter setting | 3 buttons | 3 buttons | 3 buttons |
Cable fixing | PG 13.5 cable gland | PG 13.5 cable gland | PG 13.5 cable gland |
Housing material | ABS | Die cast aluminum | Cast aluminum with powder coating |
Sensor material | PVC or PTFE | PVC or PTFE | PVC or PTFE with metal sleeve |
Protection grade | IP67 | IP67 | IP67 |
Explosion-proof | NA | NA | Ex( ia ) IICT6 |
Mounting | Thread, Flanged, or Bracket | Thread, Flanged, or Bracket | Thread, Flanged |
Measuring range (meter) | 0.2-4, 0.25-6, 0.3-8, 0.4-10, 0.6-15, 1.2-20, 1.4-30, 1.6-40 | 0.2-4, 0.25-6, 0.3-8, 0.4-10, 0.6-15, 1.2-20, 1.4-30, 1.6-40 | 0.2-4, 0.4-4, 0.3-8, 0.45-8 |
Accuracy | 0.2%FS | 0.2%FS | 0.2%FS |
Current output | 4-20mA | 4-20mA | 4-20mA |
Output load | 0-500Ω | 0-500Ω | 0-600Ω |
Display | LCD 4-digit | LCD 4-digit | LCD 4-digit |
Power supply | DC20-32V ≥30mA | DC20-32V ≥30mA | DC21-27V ≥35mA |
Temperature Compensation | Whole-range compensation | Whole-range compensation | Whole-range compensation |
Media Temp. | -45 ℃~ 85 ℃ | -45 ℃~ 85 ℃ | -20 ℃~ 75 ℃ |
Pressure range | ±0.1Mpa | ±0.1Mpa | ±0.1Mpa |
Beam Angle | 8°, 5°(3db) | 8°, 5°(3db) | 8°(3db) |
Measure cycle | 1 second | 1 second | 1~ 20 seconds |
Parameter setting | 3 buttons | 3 buttons | 3 buttons |
Cable fixing | PG 13.5 cable gland | PG 13.5 cable gland | PG 13.5 cable gland |
Housing material | ABS | Die cast aluminum | Cast aluminum with powder coating |
Sensor material | PVC or PTFE | PVC or PTFE | PVC or PTFE with metal sleeve |
Protection grade | IP67 | IP67 | IP67 |
Explosion-proof | NA | NA | Ex( ia ) IICT6 |
Mounting | Thread, Flanged, or Bracket | Thread, Flanged, or Bracket | Thread, Flanged |
Measuring range (meter) | 0.2-4, 0.25-6, 0.3-8, 0.4-12, 0.6-15, 1.2-20, 1.4-30, 1.6-40 | 0.2-4, 0.25-6, 0.3-8, 0.4-12, 0.6-15, 1.2-20, 1.4-30, 1.6-40 |
Accuracy | 0.2%FS | 0.2%FS |
Current output | 4-20mA (optional: with Hart protocol) | 4-20mA (optional: with Hart protocol) |
Output load | 0-500Ω | 0-500Ω |
Relay output | Up-limit and low-limit (total 2 relay output normally open contact) | Up-limit and low-limit (total 2 relay output normally open contact) |
Relay Spec. | 5A 250VAC / 30VDC | 5A 250VAC / 30VDC |
Display | LCD 4-digit | LCD 4-digit |
Power supply | DC20-32V ≥60mA or AC85-265V ≥50mA | DC20-32V ≥60mA or AC85-265V ≥50mA |
Temperature compensation | Whole-range compensation | Whole-range compensation |
Media Temp. | -45 ℃~ 85 ℃ | -45 ℃~ 85 ℃ |
Pressure range | ±0.1Mpa | ±0.1Mpa |
Beam Angle | 8°, 5°(3db) | 8°, 5°(3db) |
Measure cycle | 1 second | 1 second |
Parameter setting | 3 buttons | 3 buttons |
Cable fixing | PG 13.5 cable gland | PG 13.5 cable gland |
Housing material | ABS | Die cast aluminum |
Sensor material | PVC or PTFE | PVC or PTFE |
Protection grade | IP67 | IP67 |
Explosion-proof | NA | NA |
Mounting | Thread, Flanged, or Bracket | Thread, Flanged, or Bracket |
Measuring range (meter) | 0.2-4, 0.25-6, 0.3-8, 0.4-10, 0.6-15, 1.2-20, 1.4-30, 1.6-40 | 0.2-4, 0.25-6, 0.3-8, 0.4-10, 0.6-15, 1.2-20, 1.4-30, 1.6-40 |
Accuracy | 0.2%FS | 0.2%FS |
Current output | 4-20mA | 4-20mA |
Output load | 0-500Ω | 0-500Ω |
Communication | RS485 ( Modbus protocol) | RS485 ( Modbus protocol) |
Baud rate | 19200 / 9600 / 4800 | 19200 / 9600 / 4800 |
Display | LCD 4-digit | LCD 4-digit |
Power supply | DC20-32V ≥60mA | DC20-32V ≥60mA |
Temperature compensation | Whole-range compensation | Whole-range compensation |
Media Temp. | -45 ℃~ 85 ℃ | -45 ℃~ 85 ℃ |
Pressure range | ±0.1Mpa | ±0.1Mpa |
Beam Angle | 8°, 5°(3db) | 8°, 5°(3db) |
Measure cycle | 1 second | 1 second |
Parameter setting | 3 buttons | 3 buttons |
Cable fixing | PG 13.5 cable gland | PG 13.5 cable gland |
Housing material | ABS | Die cast aluminum |
Sensor material | PVC or PTFE | PVC or PTFE |
Protection grade | IP67 | IP67 |
Explosion-proof | NA | NA |
Mounting | Thread, Flanged, or Bracket | Thread, Flanged, or Bracket |