Exhaust Air Heat Recovery Fresh Air Machine

Exhaust Air Heat Recovery Fresh Air Machine
Exhaust Air Heat Recovery Fresh Air Machine
Request a Quote
  • Ceiling Exhaust Air Heat Recovery Fresh Air Machine
  • Cabinet Exhaust Air Heat Recovery Fresh Air Machine

Exhaust air heat recovery fresh air machine is able for cooling, heating, dehumidification, humidification, filtering, etc., providing high-quality fresh with constant temperature for various situations. The unit is able for recycling waste heat produced by air exhausting, which helps save 20%~30% more energy than common fresh air ventilation air conditioning system. WARM provides ceiling and cabinet types of exhaust air heat recovery fresh air machine sorted by different installation methods.

Features
  • Evaporator and condenser are isolated from each other, which helps avoid cross contamination from germs and harmful substances, and make fresh air cleaner.
  • The unit features compact structure and is easy to install, able for efficiency running with only linking the air duct. The unit takes small architectural space and helps save much cost.

Ceiling Exhaust Air Heat Recovery Fresh Air Machine

WMVF35D
Rated Cool Capacity 2.4kW
Rated Heating Capacity 2.6kW
Rated Refrigerating Power 0.8kW
Power Supply 220V/1Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 350m³/h
Fresh Air System Exterior Excess Pressure 120Pa
Air Outlet Rate 350m³/h
Air Outlet System Exterior Excess Pressure 120Pa
Weight 170kg
Size 1500x1190x550mm
WMVF50D
Rated Cool Capacity 3.2kW
Rated Heating Capacity 3.3kW
Rated Refrigerating Power 1.1kW
Power Supply 220V/1Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 500m³/h
Fresh Air System Exterior Excess Pressure 120Pa
Air Outlet Rate 500m³/h
Air Outlet System Exterior Excess Pressure 120Pa
Weight 190kg
Size 1500x1190x550mm
WMVF75D
Rated Cool Capacity 5.1kW
Rated Heating Capacity 5.3kW
Rated Refrigerating Power 1.7kW
Power Supply 220V/1Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 750m³/h
Fresh Air System Exterior Excess Pressure 150Pa
Air Outlet Rate 750m³/h
Air Outlet System Exterior Excess Pressure 150Pa
Weight 280kg
Size 1500x1190x550mm
WMVF100D
Rated Cool Capacity 7.1kW
Rated Heating Capacity 7.6kW
Rated Refrigerating Power 2.2kW
Power Supply 220V/1Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 1000m³/h
Fresh Air System Exterior Excess Pressure 150Pa
Air Outlet Rate 1000m³/h
Air Outlet System Exterior Excess Pressure 150Pa
Weight 320kg
Size 1500x1190x550mm
WMVF150D
Rated Cool Capacity 11kW
Rated Heating Capacity 11.8kW
Rated Refrigerating Power 3.9kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 1500m³/h
Fresh Air System Exterior Excess Pressure 150Pa
Air Outlet Rate 1500m³/h
Air Outlet System Exterior Excess Pressure 150Pa
Weight 420kg
Size 1600x1390x650mm
WMVF200D
Rated Cool Capacity 15kW
Rated Heating Capacity 16.2kW
Rated Refrigerating Power 5.2kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 2000m³/h
Fresh Air System Exterior Excess Pressure 150Pa
Air Outlet Rate 2000m³/h
Air Outlet System Exterior Excess Pressure 150Pa
Weight 480kg
Size 1700x1600x650mm
WMVF300D
Rated Cool Capacity 21.3kW
Rated Heating Capacity 21.6kW
Rated Refrigerating Power 7.4kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 3000m³/h
Fresh Air System Exterior Excess Pressure 250Pa
Air Outlet Rate 3000m³/h
Air Outlet System Exterior Excess Pressure 250Pa
Weight 550kg
Size 1700x1600x650mm
WMVF400D
Rated Cool Capacity 33.8kW
Rated Heating Capacity 34.5kW
Rated Refrigerating Power 11.5kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 4000m³/h
Fresh Air System Exterior Excess Pressure 250Pa
Air Outlet Rate 4000m³/h
Air Outlet System Exterior Excess Pressure 250Pa
Weight 660kg
Size 1700x1720x700mm

Cabinet Exhaust Air Heat Recovery Fresh Air Machine

WMVF200
Rated Cool Capacity 19.6kW
Rated Heating Capacity 21.2kW
Rated Refrigerating Power 6.5kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 3000m³/h
Fresh Air System Exterior Excess Pressure 150Pa
Air Outlet Rate 3000m³/h
Air Outlet System Exterior Excess Pressure 250Pa
Weight 520kg
Size 1760x1130x1650mm
WMVF300
Rated Cool Capacity 29.8kW
Rated Heating Capacity 30.2kW
Rated Refrigerating Power 9.8kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 4000m³/h
Fresh Air System Exterior Excess Pressure 250Pa
Air Outlet Rate 4000m³/h
Air Outlet System Exterior Excess Pressure 250Pa
Weight 580kg
Size 1760x1130x1650mm
WMVF400
Rated Cool Capacity 39.8kW
Rated Heating Capacity 41.2kW
Rated Refrigerating Power 13.3kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 5000m³/h
Fresh Air System Exterior Excess Pressure 250Pa
Air Outlet Rate 4000m³/h
Air Outlet System Exterior Excess Pressure 250Pa
Weight 650kg
Size 2160x1330x1850mm
WMVF500
Rated Cool Capacity 49.6kW
Rated Heating Capacity 50.5kW
Rated Refrigerating Power 16.6kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 6000m³/h
Fresh Air System Exterior Excess Pressure 250Pa
Air Outlet Rate 5000m³/h
Air Outlet System Exterior Excess Pressure 250Pa
Weight 720kg
Size 2160x1530x1850mm
WMVF600
Rated Cool Capacity 59.6kW
Rated Heating Capacity 60.3kW
Rated Refrigerating Power 19.8kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 7000m³/h
Fresh Air System Exterior Excess Pressure 500Pa
Air Outlet Rate 6000m³/h
Air Outlet System Exterior Excess Pressure 500Pa
Weight 880kg
Size 2160x1830x1850mm
WMVF800
Rated Cool Capacity 79.4kW
Rated Heating Capacity 80.2kW
Rated Refrigerating Power 26.5kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 9000m³/h
Fresh Air System Exterior Excess Pressure 500Pa
Air Outlet Rate 8000m³/h
Air Outlet System Exterior Excess Pressure 500Pa
Weight 1000kg
Size 2160x1830x2100mm
WMVF1000
Rated Cool Capacity 98.5kW
Rated Heating Capacity 99.2kW
Rated Refrigerating Power 32.8kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 11000m³/h
Fresh Air System Exterior Excess Pressure 500Pa
Air Outlet Rate 10000m³/h
Air Outlet System Exterior Excess Pressure 500Pa
Weight 1200kg
Size 2360x2100x2250mm
WMVF1200
Rated Cool Capacity 118.6kW
Rated Heating Capacity 119.3kW
Rated Refrigerating Power 39.5kW
Power Supply 380V/3Ph/50Hz
Refrigerant R22/R410A
Fresh Air Flow Rate 13000m³/h
Fresh Air System Exterior Excess Pressure 500Pa
Air Outlet Rate 12000m³/h
Air Outlet System Exterior Excess Pressure 500Pa
Weight 1500kg
Size 2360x2100x2250mm