H07RN-F Multicore Rubber Insulated Power Cable
Conductor: Bare copper, tinned copper
Insulator: EPR rubber
Jacket: CPE rubber
Rated volt.: 450/750V
Test voltage: 2000V. 5Min
Rated temp.: -30℃~ 70℃
Application
Rubber insulated power cable is popularly used in locomotive equipment, electric motor, marine cable, mineral, underwater, welding machines etc.
No. of Cores x Nominal Cross Sectional (core x mm²) | Nominal Thickness of Insulation (mm) | Nominal Thickness of Sheath (mm) | Nominal Overall Diameter ( mm min-max) | Nominal Copper Weight (kg/Km) | Nominal Weight (kg/Km) |
2 x 1.0 | 0.8 | 1.3 | 7.7-10 | 19 | 89 |
3 x 1.0 | 0.8 | 1.4 | 8.3-10.7 | 29 | 111 |
4 x 1.0 | 0.8 | 1.5 | 9.2-11.9 | 38 | 146 |
1 x 1.5 | 0.8 | 1.4 | 5.7-7.1 | 14.4 | 59 |
2 x 1.5 | 0.8 | 1.5 | 8.5-11.0 | 29 | 135 |
3 x 1.5 | 0.8 | 1.6 | 9.2-11.9 | 43 | 165 |
4 x 1.5 | 0.8 | 1.7 | 10.2-13.1 | 58 | 200 |
5 x 1.5 | 0.8 | 1.8 | 11.2-14.4 | 72 | 240 |
7 x 1.5 | 0.8 | 2.6 | 14.5-17.5 | 101 | 385 |
12 x 1.5 | 0.8 | 2.9 | 17.6-22.4 | 173 | 516 |
19 x 1.5 | 0.8 | 3.2 | 20.7-26.3 | 274 | 800 |
24 x 1.5 | 0.8 | 3.5 | 24.3-30.7 | 346 | 882 |
1 x 2.5 | 0.9 | 1.4 | 6.3-7.9 | 24 | 72 |
2 x 2.5 | 0.9 | 1.7 | 10.2-13.1 | 48 | 195 |
3 x 2.5 | 0.9 | 1.8 | 10.9-14.0 | 72 | 235 |
4 x 2.5 | 0.9 | 1.9 | 12.1-15.5 | 96 | 290 |
5 x 2.5 | 0.9 | 2.0 | 13.3-17.0 | 120 | 345 |
7 x 2.5 | 0.9 | 2.8 | 16.5-20.0 | 168 | 520 |
12 x 2.5 | 0.9 | 3.1 | 20.6-26.2 | 288 | 810 |
19 x 2.5 | 0.9 | 3.5 | 25.5-31.0 | 456 | 1200 |
24 x 2.5 | 0.9 | 3.9 | 28.8-36.4 | 576 | 1650 |
1 x 4.0 | 1.0 | 1.5 | 7.2-9.0 | 38 | 99 |
2 x 4.0 | 1.0 | 1.8 | 11.8-15.1 | 77 | 270 |
3 x 4.0 | 1.0 | 1.9 | 12.7-16.2 | 115 | 320 |
4 x 4.0 | 1.0 | 2.0 | 14.0-17.9 | 154 | 395 |
5 x 4.0 | 1.0 | 2.2 | 15.6-19.9 | 192 | 485 |
7 x 4.0 | 1.0 | 3.1 | 18.2-21.8 | 269 | 681 |
1 x 6.0 | 1.0 | 1.6 | 7.9-9.8 | 58 | 130 |
3 x 6.0 | 1.0 | 2.1 | 14.1-18.0 | 173 | 495 |
4 x 6.0 | 1.0 | 2.3 | 15.7-20.0 | 230 | 610 |
5 x 6.0 | 1.2 | 3.6 | 17.5-22.2 | 288 | 760 |
1 x 10 | 1.2 | 1.8 | 9.5-11.9 | 96 | 230 |
3 x 10 | 1.2 | 3.3 | 19.1-24.2 | 288 | 880 |
4 x 10 | 1.2 | 3.4 | 20.9-26.5 | 384 | 1060 |
5 x 10 | 1.2 | 3.6 | 22.9-29.1 | 480 | 1300 |
1 x 16 | 1.2 | 1.9 | 10.8-13.4 | 154 | 320 |
3 x 16 | 1.2 | 3.5 | 21.8-27.6 | 461 | 1090 |
4 x 16 | 1.2 | 3.6 | 23.8-30.1 | 614 | 1345 |
5 x 16 | 1.2 | 3.9 | 26.4-33.3 | 768 | 1680 |
1 x25 | 1.4 | 2 | 12.7-15.8 | 240 | 450 |
3 x 25 | 1.4 | 2.2 | 28.5-32.0 | 675 | 1509 |
4 x 25 | 1.4 | 4.1 | 28.9-36.6 | 960 | 1995 |
5 x 25 | 1.4 | 4.4 | 32.0-40.4 | 1200 | 2470 |
1 x 35 | 1.4 | 2.2 | 14.3-17.9 | 336 | 605 |
3 x 35 | 1.4 | 4.1 | 29.3-37.1 | 1008 | 1900 |
4 x 35 | 1.4 | 4.4 | 32.5-41.1 | 1344 | 2645 |
5 x 35 | 1.4 | 4.7 | 37.0-45.0 | 1680 | 2810 |
1 x 50 | 1.6 | 2.4 | 16.5-20.6 | 480 | 825 |
3 x 50 | 1.6 | 3.2 | 39.1-43.5 | 1350 | 2836 |
4 x 50 | 1.6 | 4.8 | 37.7-47.5 | 1920 | 3635 |
5 x 50 | 1.6 | 5.1 | 40.0-50.8 | 2400 | 4050 |
1 x 70 | 1.6 | 2.6 | 18.6-23.3 | 672 | 1090 |
4 x 70 | 1.6 | 5.2 | 42.7-54.0 | 2688 | 4830 |
1 x 95 | 1.8 | 2.8 | 20.8-26.0 | 912 | 1405 |
4 x 95 | 1.8 | 5.9 | 48.4-61.0 | 3648 | 6320 |
1x 120 | 1.8 | 3 | 22.8-28.6 | 1152 | 1746 |
4 x 120 | 1.8 | 6 | 53.0-66.0 | 4608 | 6830 |
1 x 150 | 2 | 3.2 | 25.2-31.4 | 1440 | 1887 |
1 x 185 | 2.2 | 3.4 | 27.6-34.4 | 1776 | 2274 |
1x 240 | 2.4 | 3.5 | 30.6-38.3 | 23.4 | 2956 |
1 x 300 | 2.6 | 3.6 | 33.5-41.9 | 2880 | 3479 |
Mechanical Properties
Insulator physical performance
Tensile strength: ≥5N/mm2
Elongation at break of insulation: ≥250%
Jacket physical performance
Tensile strength: ≥7N/mm2
Elongation at break of insulation: ≥300%
Min.Bending radius: 7×OD
Standards: IEC60332-1, IEC60228, VDE 0293
Characteristics
Rubber cable has good performance, including low hardness, good flexibility, high tear strength, flame retardant performance, thermal stability. It can bear the temperature from -30℃ ~ 70℃. It’s also anti-UV and anti-ozone.
Other similar styles: H05RN-F, H05RR-F, YZW, YZ, YC, YCW
Packing&Delivery