Glass-Lined Reactor, F Type

Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Glass-Lined Reactor, F Type
Request a Quote

Main Features
1.The F type glass lined reactor comes with a one-piece design that the cover and body can not be separated. Due to that, a manhole has to be designed on the head of the reactor to make it easy for operators to enter the reactor to carry out maintenance and parts replacement.
2. It is a large capacity industrial process reactor, suitable for large scale production environment.
3. Similar to the K-type reactor, this type of chemical reactor is manufactured using TJ09 high end enamel and skilled enameling process. This enables the glass lining to be remarkably corrosion resistant, impact resistant and temperature variation resistant, combined with less prone to fracture and high durability.
4. Taiji is able to design and manufacture non standard glass lined reactor to user's requirements.
5. Our F type glass lined steel reactor comes in complete specifications, including F1500L, F2000L, F3000L, F4000L, F5000L, F6300L, F8000L, F10000L, F12500L, F16000L, F20000L, F30000L, F50000L, etc.

  • Parameter Test
  • Finished Product Inspection
  • Transportation
  • Transportation
Technical Parameters of the Glass-Lined Reactor
Design Drawing of F1500L-F6300L Glass-Lined Reactor
Internal Vessel Jacket
Design Pressure
(MPa)
0.4/0.6/1.0 0.6/1.0
Design Temperature
( ℃ )
-19 ℃ /200℃ -19 ℃ /200℃
Symbol Usage
a Manhole
b Agitator Hole
c Thermowell
d, f, g, h Spare
e Sightglass
j Medium Outlet
k1, k2, k3 In/Outlet
n1, n2, n3 Spray Nozzle
m Vent Hole
Nozzle Design Drawing (Plan View)
Unit: mm
Specifications F1500LF2000LF3000LF4000LF5000LF6300L
Nominal Capacity (L) 1500 2000 3000 4000 5000 6300
Total Capacity (L) 2020 2470 3860 4795 6040 6900
Calculated Capacity(Notes 1) (L) 1990 2440 3830 4795 6016 6872
Jacket Capacity (L) 301 390 495 805 898 1015
Heat Exchange Area ( m2 ) 5.92 7.31 9.98 12.44 14.06 16.36
Reference Weight (kg) 2120 2380 3360 3905 4720 5200
Main
Dimensions
d1 1300 1300 1600 1600 1750 1750
d2 1450 1450 1750 1750 1900 1900
d3(Notes 2) 1622 1622 1964 1964 2152 2152
d4 680 680 720 720 720 720
d5 700 700 800 800 850 850
h1 1801 2136 2250 2730 2888 3244
h2 190 190 190 190 190 190
h3 725 725 700 700 750 750
h4 975 975 1060 1060 1200 1200
B1 315 315 315 315 350 350
B2 510 510 510 510 510 510
Φ 30 30 30 30 30 30
Nozzle DN a 300×400 300×400 300×400 300×400 300×400 300×400
b 125 125 150 150 150 150
c 100 100 100 100 125 125
d 100 100 100 100 125 125
e 125 125 125 125 125 125
f 125 125 125 125 150 150
g 100 100 100 100 125 125
h 125 125 125 125 150 150
j 100 100 125 125 125 125
Jacket
Nozzle DN
k1 40 40 65 65 65 65
k2 40 40 65 65 65 65
k3 40 40 65 65 65 65
n1 50 50 65 65 65 65
n2 / / / 65 65 65
n3 50 50 65 65 65 65
m G3/8" G3/8" G3/8" G3/8" G3/8" G3/8"
Drive DN 80 80 95 95 95 95
h5 1320 1320 1360 1360 1360 1530
Notes 1: Calculated Capacity: Volume under highneck flange.
Notes 2: Types of support depend on users; if there is no special request, lugs would be normally applied.
Design Drawing of F8000L-F50000L Glass-Lined Reactor
Inner Vessel Jacket
Design Pressure
(MPa)
0.4/0.6/1.0 0.6/1.0
Design Temperature
( ℃ )
-19 ℃ /200℃ -19 ℃ /200℃
Symbol Usage
a Medium Outlet
b1,b2,b3,b4 In/Outlet
c Manhole
d Agitator Hole
e1 Thermowell
e2, g1, g2, g3, g4, k Spare
h Sightglass
m Vent Hole
n Clean Hole
  • F50000L Nozzle Design (Plan View)
  • F8000L Nozzle Design (Plan View)
  • F10000L~F30000L Nozzle Design (Plan View)
Unit: mm
Specifications F8000L F10000L F12500LF16000L F20000L F30000L F50000L
Nominal Capacity (L) 8000 10000 12500 16000 20000 30000 50000
Total Capacity (L) 9105 11719 13696 17491 21835 33645 56444
Calculated Capacity(Notes 1) (L) 9060 11674 13651 17446 21790 33500 55514
Jacket Capacity (L) 1666 1940 2243 2551 2870 3700 4520
Heat Exchange Area ( ㎡ ) 18.38 21.35 24.89 29.48 34.04 45 34.04
Reference Weight (kg) 6959 7911 9342 11222 13530 19270 34590
Main

Dimension
d1 2000 2200 2200 2400 2600 3000 3800
d2 2200 2400 2400 2600 2800 3200 4000
d3(Notes 2) 2452 2703 2703 2908 3179 / /
h1 3310 3533 4053 4346 4641 5340 5611
h2 210 210 210 210 210 260 647
h3 850 900 900 950 1000 1150 1340
h4 1200 1300 1300 1400 1550 / /
h 5400 5600 6530 7010 7475 8835 10425
B1 400 470 470 470 470 470 470
B2 510 550 550 550 550 550 550
Φ 30 36 36 36 36 / /
Nozzle DN a 125 150 150 150 150 150 150
c 300×400 300×400 300×400 450 450 450 450
d 200 200 200 200 250 250 250
e1 200 200 200 200 200 200 200
e2 150 200 200 200 200 200 200
e3 / / / / / / 200
g1 150 150 150 150 150 150 150
g2 150 150 150 150 150 150 150
g3 / 150 150 150 150 150 150
g4 150 150 150 150 150 150 150
h 125 125 125 125 125 125 125
k 125 125 125 125 125 125 125
Jacket
Nozzle DN
b1 65 80 80 100 100 100 125
b2 65 80 80 100 100 100 125
b3 65 80 80 100 100 100 125
b4 / 80 80 100 100 100 100
f1 65 80 80 100 100 100 100
f2 65 80 80 100 100 100 100
f3 65 80 80 100 100 100 100
m G3/4" G3/4" G3/4" G3/4" G3/4" G3/4" G3/4"
n G1/2" G1/2" G1/2" G1/2" G1/2" G1/2" G1/2"
Drive DN 110 110 110 130 140 160 160
h5 1375 1375 1375 1995 2190 2420 2640
Notes 1: Calculated Capacity: Volume under highneck flange.
Notes 2: Support types could be determined by users; if there is no special request, lugs would be normally applied.
Samples Show
  • Upper Structure
  • Manhole with Sight Glass
  • Bottom Outlet
  • Bottom View
  • Side View
  • Front View
  • Production Line
Related products
Send Message
Other Products
Inquiry
Inquiry