Industrial Cable Manufacturer

Industrial Cable Manufacturer
Request a Quote
Description of GJFJH fiber, single core optical cable

This product uses a single Ф900μm or Ф600μm flame retardant tight buffered optical cable as the optical transmission medium. The aramid yarn layer serves as the strength member on the exterior, then finally, an extruded buffer layer of PVC, LSZH, Hytrel, TPU, ETFE and other different materials are used as the sheathe.

Application
  • Indoor optical cable cabling
  • Optical fiber jumper wire or pigtail wire
  • Indoor vertical shaft or forced ventilation wiring
  • Instruments and telecommunication equipment interconnection
Parameter
Technical parameter
Item Content Value
Number of cores 1
Tight-buffered optical fiber Material LSZH
Outer diameter/mm (0.6/0.9)±0.05
Strength member Material Aramid yarn
Outer sheath Thickness /mm ≥0.2 ≥0.3 ≥0.4 ≥0.4
Outer diameter mm 1.6±0.1 2.0±0.1 2.8±0.1 3.0±0.1
Operating temperature -20~+60
Tensile force Short term/long term N 80/40 100/60 150/80 150/80
Flatten Short term/long term N 500/100
*We can design the structure of optical cable according to customer requirements.
Characteristics of optical fiber

G.652.D G.657A2 50/125μm 62.5/125μm
Attenuation @850nm - - ≤3.0dB/km ≤3.0dB/km
@1300nm - - ≤1.0dB/km ≤1.0dB/km
@1310nm ≤0.36dB/km ≤0.36dB/km - -
@1550nm ≤0.22dB/km ≤0.23dB/km - -
Bandwidth @850nm - - ≥500MHz·km ≥200MHz·km
@1300nm - - ≥1000MHz·km ≥600MHz·km
Fiber cutoff wavelength
≤1260nm ≤1260nm - -
Polarization mode dispersion Single optical fiber ≤0.20ps/√km ≤0.20ps/√km - -
Link value (M=20, Q=0.01%)
≤0.10ps/√km - -
Main machinery and environment performance
Item Inspection standard Procedure of inspection Requirements
Pull IEC 60794-1-2-E1 According to technical parameter Residual additional attenuation≤0.03dB
Flatten IEC 60794-1-2-E3 According to technical parameter Additional attenuation for long term≤0.03dB
Impact IEC 60794-1-2-E4 Impact: 1N, height: 1m, 3 points at least The optical fiber will not be broken off.
Backward and forward bending IEC 60794-1-2-E6 Load: 20N 200times Residual additional attenuation≤0.03dB
Temperature recycle test IEC 60794-1-2-F1 -20℃ ~+60℃ Additional attenuation: single-mode≤0.5dB; multi-mode≤0.3dB
Combustion performance IEC 60332-1-2 Fire resistance Every single wire can be burnt vertically.
Density of the smoke Light transmittance ≥50%
Corrosiveness PH of the gas when burning≤4.3, electric conductivity≤10μs/mm
* The monitoring of all optical fiber attenuation's change is operated in wavelength of 1550nm.
Features
  • The tight buffered optical fiber is easy to strip, and it features an excellent flame retardant performance.
  • The aramid yarn layer serves as the strength member, giving the optical cable an excellent tensile property.
  • This product is corrosion resistant, waterproof, ultra-violet resistant, flame retardant and environmentally friendly.
  • The all-dielectric structure protects the optical fiber from electromagnetic interference.
Related products
Send Message
Other Products
Inquiry
Inquiry