High Temperature Fire Alarm Detection System

High Temperature Fire Alarm Detection System
Request a Quote

The fire detection and alarm system passed industrial quality test for temperature-sensing alarm and complies with EN54-2 GB47816-2005 U1521 standard.


Technical Parameters of Fire Detection and Alarm System
Temperature range 10-180℃
Temperature increase speed 0.1-30℃min, adjustable
Temperature deviation ±2℃
Air speed 0.5-1.0ms, adjustable
Air flow Stable
Test accuracy of temperature ±0.2℃
Test accuracy of air speed 0.15m/s
Software testing Yes
  • Simplewell controller
  • Mitsubishi PLC
  • Temperature and humidity adjustment range
Optional Configurations

1. Rotary dehumidifier/ polymeric membrane, with a lowest temperature/ humidity content of 5℃/5 %RH.

2. Built-in tempered glass door, easy to move

3. Water purification system, with automatic replenishment function

4. Recorder, save and print testing data

5. Ultrasonic humidifier/ high-pressure spray humidifier, providing continuous high humidity under extreme temperature

6. Dry air blow system, anti-condensation

7. Remote monitoring function, cellphone and computer supportive

Cooling Equipment

  • TECUMSEH fully hermetic compressor
  • BOCK inverter compressor
  • BITZER semi-hermetic compressor
Tags
Related Manufacturies
Leave Message
Similar Manufacturies and Parts
Inquiry
Inquiry