Mould Temperature Controller (Water Heater)
Request a Quote
STM-W
Hot water system for mould heating and temperature maintaining
Our water-based mould temperature controllers are designed for the efficient and precise control of mould temperatures in plastic processing. By using water as a heat transfer medium, these systems offer an environmentally friendly and cost-effective solution, enhancing the production environment's safety. The closed-loop water circulation keeps the system stable even at temperatures above 100°C, ensuring reliable temperature management. Additionally, these systems are customizable with various accessories to meet specific production needs.
Features
- Reaches up to 120°C, ideal for various industrial applications.
- Fully digital P.I.D. temperature control maintains stability within ±0.5°C accuracy, crucial for consistent product quality.
- The use of solid-state relays ensures reliable and long-lasting performance.
- The system boasts a high-efficiency water circulation pump that significantly enhances thermal transfer.
- Equipped with a comprehensive array of safety features including phase reversal protection, pump thermal overload protection, and over-temperature protection to ensure operation without hazards.
- Advanced features include high and low-pressure management, automatic water replenishment, and efficient start-up venting.
- Direct cooling capability allows for rapid adjustment to desired temperatures, facilitating fast cycle times and energy savings.
- The user interface is designed for accessibility, supporting multiple languages and allowing for simple conversions between temperature units.
- Supports multilingual operations and allows for easy switching between Celsius and Fahrenheit, facilitating user interaction and accessibility.
- Includes an RS485 communication interface, facilitating seamless integration into centralized control systems for superior monitoring and management.
Specifications
Model | Max. temperature | Heater power (kW) | Pump power (kW) | Max. pump flow (L/min) | Max. pump pressure (bar) | Number of heating tank | Heating tank capacity (L) | Cooling method | Inlet/outlet size (Euro PT female thread) (inch) | Dimensions (mm) (H×W×D) | Weight (kg) |
120℃ (140C)** | 6 | 0.55 | 27 | 3.8 | 1 | 3.0 | Direct cooling | 314/314 | 620×320×865 | 55 | |
9 | 0.75 | 42 | 5.0 | 1 | 3.0 | 314/314 | 620×320×865 | 60 | |||
12 | 1.5 | 74 | 6.2 | 1 | 3.0 | 1/1 | 630×320×885 | 69 | |||
24 | 2.8 | 90 | 8.0 | 2 | 7.4 | 1/1 | 830×360×955 | 140 | |||
36 | 4 | 100 | 8.0 | 3 | 17.7 | 1/1 | 965×470×1100 | 150 | |||
Notes: 1) Pump test conditions: power of 50Hz, purified water at 20℃ (±10% tolerance for either maximum flow rate or maximum pressure) 2) Power: 3φ, 400VAC, 50Hz 3) "**" stands for that the cooling water pressure should not be lower than 4bar when heaing the machine to 140℃ | We reserve the right to change specifications without prior notice. |