Indoor LED Power Supply, 150W

Indoor LED Power Supply, 150W
Indoor LED Power Supply, 150W
Indoor LED Power Supply, 150W
Indoor LED Power Supply, 150W
Indoor LED Power Supply, 150W
Indoor LED Power Supply, 150W
Request a Quote

Features:
AC input range of the LED power supply is selectable by switch.
Protections: Short circuit/ Overload / Over voltage
Cooling by free air convection
LED indicator on the indoor power supply shows when the power is on.
100% full load burn-in test
High efficiency, long life and high reliability
2 years warranty for the lighting power supply

Technical Specification

MODEL PW150-9D-167A-MW
OUTPUT DC VOLTAGE 24V
RATED CURRENT 6.5A
CURRENT RANGE 0~6.5A
RATED POWER 156W
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE 22.8~27.6V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION Note.4 ±0.5%
LOAD REGULATION Note.5 ±0.5%
SETUP, RISE TIME Note.8 800ms, 20ms/230VAC 1200ms, 30ms/115VAC
HOLD UP TIME (Typ .) 24ms/230VAC 20ms/115VAC
INPUT VOLTAGE RANGE 90 ~132VAC/180 ~264VAC selected by switch
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ .) 86%
AC CURRENT (Typ .) 3A /115VAC 2A/230VAC
INRUSH CURRENT (Typ .) COLD START 45A/230VAC
LEAKAGE CURRENT <2mA/240VAC
PROTECTION OVERLOAD 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVERVOLTAGE 27.6 ~ 32.4V
Protection type: Hiccup mode, recovers automatically after the cause of fault is removed
ENVIRONMENT WORKING TEMP. -20 ~ 60℃ (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40~ 85℃ , 10~95% RH
TEMP. COEFFICIENT ±0.03%/ ℃ (0 ~ 50℃ )
VIBRATION 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X , Y, Z axes
SAFETY & EMC(Note 7) SAFETY STANDARDS Note.6 UL60950-1, TUV EN60950-1 , GB4943.1:2011 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 70% RH
EMI CONDUCTI0N & RADIATION Compliance to EN55022 (CISPR22) Class B , GB9254 CLASS B
HARMONIC CURRENT Compliance to EN61000-3-2,-3,GB17625.1
EMS IMMUNITY Compliance to EN61000-4-2,3 , 4,5 , 6 , 8,11, ENV50204 , EN55024 , EN61000-6-1, heavy industry level, criteria A
OTHERS MTBF 433.3Khrs min. MIL-HDBK-217F (25℃ )
DIMENSION 199*98*38mm(L*W*H)
PACKING 0.7Kg ;20pcs/15Kg/0.72CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple and noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf and 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. According to GB4943.1 regulations, the power supply is only suitable for use in altitudes 2,000m and below and in non-tropical climates.
7. The power supply is considered a separate component which will be installed in the final equipment. The final equipment must confirm that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies.” (as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning the power supply ON/OFF very quickly may increase the set up time.