CMS 10kVA UPS, Scalable to 100kVA, 400V, 64pcs Battery

CMS 10kVA UPS, Scalable to 100kVA, 400V, 64pcs Battery
CMS 10kVA UPS, Scalable to 100kVA, 400V, 64pcs Battery
Request a Quote

The CMS 10kVA UPS is one of our modular UPS systems. It is a suitable solution for small or medium-sized power required projects. The CMS 10kVA UPS has a compact structure (floor area 0.48㎡), reliable performance and necessary redundancy. Each module has a power of 10kVA and can be upgraded to 50kVA or 100kVA UPS systems according to your specific circumstances.

CMS-50/10 UPS System
  • Maximum power:50kVA
  • Power module model:CM10
  • Module power:10kVA
  • Direct voltage: ±384V
  • Dimension: 600*800*1200mm (W*D*H), standard 19 inch cabinet
  • Weight: 120kg
CMS-100/10 UPS System
  • Maximum power:100kVA
  • Power module model:CM10
  • Module power:10kVA
  • Direct voltage: ±384V
  • Dimension: 600*800*1600 mm (W*D*H), standard 19 inch cabinet
  • Weight: 150kg
UPS System Technical Parameters
Module
Module model CM10
Module power 10kVA
Rated input voltage ±384VDC
Power connection 3/3 phase
Module dimension (W*D*H)mm 482×465×89
Weight (kg) Approximate 16 kg
Module charging Each module provides 2.5kW charging power
Input power factor ≥0.99
Overload ability Exceeds system overload requirements
Maximum heat dissipation power 475w
THDI (%) ≤3%
Mains Input
Input mode 3-phase N E, 1-phase N E
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50Hz±10%, 60Hz±10%
Power woke-in (Sec.) 60sec
THDI (%) <3%
Input PF ≥0.99
Bypass Input
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50 Hz, 60 Hz
Range of Frequency Synchro 50 Hz±4%, 60 Hz±4%
DC Input
Rated Input voltage ±384VDC
Input voltage tolerance ±345V~±440V DC
Battery Charging
Charging current limited yes
Charging ability 10 hours (2 hours back up)
Stability of charging voltage ±1%
AC Output
UPS power factor 1
Output voltage 380V/220V AC, 400V/230V AC, 415V/240V AC
Output frequency ±4%;±0.2% (battery supply)
Output voltage stability ±1%
Output voltage recovering time <20ms (load 0~100% change)
Overload ability Operate 10mins with 125% load
Transfer from mains to battery supply 0ms
Transfer from bypass to inverter supply < 1ms
Peak factor 3:01
Waveform distortion ≤1% ( linear load ), ≤3%( non-linear load )
Overall efficiency ≥95% (AC~AC), ≥98% (DC~AC)
Load share precision ≤5%
Operation Environment
Ambient temperature -25℃~60℃
Operating temperature -5℃~40℃
Maximum operation altitude ≤1500m
Relative humidity ≤95% non-cadency
Protection degree IP30
Cooling Air cooling
Applicable safety standards EN62040-1-1:2003 IEC60950-1:2001
Electromagnetic compatibility EN62040-2:2006
Acoustic noise ≤55DB
Others
Cabinet Standard 19 inch cabinet
Monitor management system UPSupervisor
Interface RS232, RS485 and 8 try contact, TCP/IP adapter, SNMP(optional)
Display Touch LCD/LED Screen
Related products
Send Message
Other Products
Inquiry
Inquiry