Industrial Cable Manufacturer

Industrial Cable Manufacturer
Industrial Cable Manufacturer
Request a Quote
Structure
  • Optical unit aluminum clad steel wire
  • Optical unit anticorrosive oil aluminum clad steel wire aluminum wire
Description

OPGW fiber integrates ground electrode and photo-communication functions all in cable one unit. This product is mainly applied to 35kV, 110kV, 220kV, 500kV, 750kV telecommunication lines of high voltage transmission systems built on stilts. OPGW fiber is also suitable for replacing old ground wires of high voltage transmission system built on stilts to add to existing optical communication lines, conduct short circuit current and protect the system from lightning strikes.

SPFO will carefully design the structure of the optical cable according to the specific service environment (like distance between towers, requirement of sag, ice load, wind load, allowed tensile force at the suspension point, message capacity, short circuit current and so on). Users can specify the structure as well.

Parameter
Technical parameter
Item Content Typical value
Quantity of optical fiber 2~48
Protecting tube Material stainless steel tube
Outer diameter/mm 1.5~6
Stranded single wire Material Aluminum clad steel, aluminum, aluminum rod
Diameter/mm 1.5~6
Maximum outer diameter mm 18
Maximum tensile force kN 280
Maximum sectional area mm² 200
Maximum short circuit current 400-200℃(Ka²*S) 100
Range of operating temperature -40~+65
Compressive resistance N/100mm 2200
* The structure of optical cable and quantity of core can be custom-made according to customer requirements.
Characteristic of optical fiber
G.652.D G.655 50/125μm 62.5/125μm
Attenuation @850nm - - ≤3.0dB/km ≤3.0dB/km
@1300nm - - ≤1.0dB/km ≤1.0dB/km
@1310nm ≤0.36dB/km ≤0.36dB/km - -
@1550nm ≤0.22dB/km ≤0.23dB/km - -
Bandwidth @850nm - - ≥500MHz·km ≥200MHz·km
@1300nm - - ≥1000MHz·km ≥600MHz·km
Fiber cutoff wavelength ≤1260nm ≤1260nm - -
Polarization mode dispersion Single optical fiber ≤0.20ps/√km ≤0.20ps/√km - -
Link value (M=20, Q=0.01%) ≤0.10ps/√km ≤0.10ps/√km - -
Main machinery and environment performance
Item Inspection standard procedure of inspection Requirements
tension IEC 60794-4-10 According to the change of optical cable's structure Additional attenuation≤0.05dB
pressure IEC 60794-20-9.4.5 2200N/100mm, 10min, 3 times interval 1m Additional attenuation≤0.1dB, non-mechanical damage
Backward and forward bending IEC 60794-4-20-9.4.3 R=15~20*D Additional attenuation≤0.05dB, non-mechanical damage
Seepage test IEC 60794-4-10-9.8 Length of sample: 0.5m, 20±5℃, height of the water: 1m, 1h Non-seepage
Dripping test IEC 60794-4 Length of sample: 0.3m, 70±1℃, 24h The filler and composition won't outflow or drip out.
Temperature recycle test IEC 60794-4-20-9.6 -40℃~+70℃ Additional attenuation≤0.1dB
Features
  • Smaller diameter; the additional load to the tower is lower.
  • The design of the stainless steel tube and stranded core is excellent. Optical fiber extra length is accurate.
  • The stainless steel tube has a higher tensile strength, and will protect the optical fiber.
  • The optical unit locates the center of the stainless steel tube to get the advantages of distortion resistance and side-pressure resistance.
  • The good security ensures that the fiber cannot be cut by knife or stolen. The damage resistance of this product is excellent.
  • There are various combinations in the armored layer or electrical properties and mechanical properties.
Standards

DL/T 832-2003 Optical Fiber Composite Ground Wire
IEC 60794-4-10-2014 Aerial Optical Wire used in Power Line

Installation

Aerial

Related products
Send Message
Other Products
Inquiry
Inquiry