Vehicle Salt Spray Test Chamber

Vehicle Salt Spray Test Chamber
Vehicle Salt Spray Test Chamber
Vehicle Salt Spray Test Chamber
Request a Quote

Vehicle salt spray test chamber is suitable for the salt spray corrosion tests of protection layer of components and parts, electronic hardware components, metal materials and industrial products.

This test chamber typically find application in automotive industry such as salt spray corrosion test of car body, chassis and engine. It can handle neutral salt spray test, acetate spray test and copper accelerated acetate salt spray test.


Standards
  • GB/T10587-2006 Specification for salt mist testing chambers
  • GB/T2423.17-2000 Environmental testing for electric and electronic products- Test Ka: Salt mist
  • GB/T 10125-2012 Corrosion tests in artificial atmospheres - salt spray tests
  • QC/T 732-2005(2012) Accelerated corrosion testing method for passenger car
  • GB/T 5170.2-08 Inspection methods for environmental testing equipment for electric and electronic products - Temp. testing equipment
  • GB/T5170.5-08 Inspection methods for environmental testing equipment for electric and electronic products - Part 5: Damp heat testing equipment
Equipment performance
1.Salt spray
Average relative velocity of air to test sample 20-60m/min
Salt spray settlement amount 1-2 (ml/80cm2..h)
NaCl solution concentration 5±0.5%
Neutral salt spray test (NSS) collection liquid PH value (6.5-7.2)
Acetate spray test (AASS) collection liquid PH value (3.0-3.3)
The copper accelerated acetic acid salt spray test (CASS) collection liquid PH value (3.0-3.3)
The angle of baffle and vertical direction 15±2
Number of sprayers 8 (Ensure even distribution of salt spray) including 2 on bottom
Spray method Air spray, continuous or interval
Saturator heating rate Room Temp. ~ 37℃, ≤ 30 min
Salt water tank heating rate Room Temp.~ 35℃, ≤30 min
Temp. range 20 ° C -80℃
2.Temp. and humidity control
Temp. range 20℃~ 50℃
Temp. deviation ±2.0℃ (no-load test)
Temp. uniformity 2.0℃
Temp. fluctuation ±0.5℃
Empty chamber: from 25℃ to 50℃≤30min, averagely
Humidity range 85~100%R.H
Humidity deviation ±5% R.H (no-load test)
Humidity uniformity 5% R.H (no-load test)
Humidity fluctuation ±2.5% R.H
Noise 5m from equipment < 70 db
Related products
Send Message
Other Products
Inquiry
Inquiry