Outdoor LED Power Supply, 150W
Request a Quote
Features:
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Outdoor power supply is up to 94% efficient
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67/IP65 design for outdoor lighting supply
Type HL LED Driver for use in Class, Division 2 hazardous location luminaires
Three-in-one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for LED power supply
Suitable for dry / damp /wet locations
Technical Specification:
MODEL | PW150-24D-063A-MW | |
OUTPUT | DC VOLTAGE | 24V |
CONSTANT CURRENT REGION Note.4 | 12-24V | |
RATED CURRENT | 6.3A | |
RATED POWER | 151.2 W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ. RANGE Note.6 | 22 -27V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer | |
3.8-6.3A | ||
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME Note.8 | 1000ms,50ms/115VAC 500ms,50ms/230VAC at full load | |
HOLD UP TIME ( Typ . ) | 16ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE Note.5 | 90 -305VAC 127-431VDC |
FREQUENCY RANGE | 47~63Hz | |
POWER FACTOR ( Typ . ) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading ≥ 60% at 115VAC/230VAC input and output loading ≥ 75% at 277VAC input | |
EFFICIENCY ( Typ . ) | 93% | |
AC CURRENT ( Typ . ) | 1.7A /115VAC 0.75A/230VAC 0.7A/277VAC | |
INRUSH CURRENT ( Typ . ) | COLD START 65A( twidth =425 m s measured at 50% Ipeak ) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/277VAC | |
PROTECTION | OVER CURRENT | 95 - 108% |
Protection type: Constant current limiting, recovers automatically after the cause of fault is removed | ||
SHORT CIRCUIT | Constant current limiting, recovers automatically after the cause of fault is removed | |
OVERVOLTAGE | 28-34V | |
Protection type: Shut down o/p voltage with auto-recovery or re-power on to recovery | ||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down |
ENVIRONMENT | WORKING TEMP. | -40 ~ 70℃ (Refer to " Derating Curve") |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ 80℃ , 10-95% RH | |
TEMP. COEFFICIENT | ± 0.03% ℃ (0-50℃ ) | |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,Y,Z axes | |
SAFETY& EMC | SAFETY STANDARDS Note.7 | UL8750, CSAC22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP67 ,J61347-1, J61347- 2-13 approved; design refer to UL60950-1, TUV EN60950-1 |
WITHSTAND VOLTAGE | I/P-0/P:3.75KVAC I/P-FG:2KVAC 0/P-FG : 1.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG , 0/P-FG:100M Ohms/500VDC/25℃70% RH | |
EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≥60% load); EN61000-3-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547, EN55024 , light industry level (surge 4KV), criteria A | |
OTHERS | MTBF | 192.2K hrs min. MIL-HDBK-217F (25℃ ) |
DIMENSION | 228*68*38.8mm(L*W*H) | |
PACKING | 1.15Kg ; 12pcs/14.8Kg/0.8CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |
2. Ripple and noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf and 47uf parallel capacitor. | ||
3. Tolerance: indudes set up tolerance, line regulation and load regulation. | ||
4. Please refer to "Driving Methods of LED Module." | ||
5. Derating may be needed under low input voltages. Please check the static characteristics for more details. | ||
6. A-type only. | ||
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, and FCC parti8. | ||
8. Length of set up time is measured at cold first start. Turning the power supply ON/OFF may increase the set up time. | ||
9. The power supply is considered a separate component that will operate in combination with the final equipment. Since EMC performance will be affected by its installation, the final equipment manufacturers must re-qualify EMC Directives on the installed product. | ||
10. Refer to warranty statement. | ||
11 .To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch that's not permanently connected to the main system. |