400-2000kW Induction Central Heating Boiler
Heating area: 3840-14400m²
Features- Electrical leakage protection;
- High pressure protection;
- Alarm function;
- Short circuit protection;
Model | Unit | BYD-C480SLC1 | BYD-C640SLC1 | BYD-C800SLC1 | BYD-C1000SLC1 | BYD-C1200SLC1 |
Rated power | KW | 480 | 640 | 800 | 1000 | 1200 |
Rated current | A | 720 | 960 | 1200 | 1500 | 1800 |
Voltage/Frequency | V/Hz | 380/50-60 | 380/50-60 | 380/50-60 | 380/50-60 | 380/50-60 |
Cross section area of power cable | m² | ≥300 | ≥400 | ≥500 | ≥500 | ≥600 |
Heating efficiency | % | ≥98 | ≥98 | ≥98 | ≥98 | ≥98 |
Max. pressure of heating | Mpa | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 |
Minimum flow rate of water pump | L/min | 576 | 768 | 960 | 1200 | 1440 |
Expansion tank volume | L | 480 | 640 | 800 | 1000 | 1200 |
Max. heating temperature | ℃ | 90 | 90 | 90 | 90 | 90 |
Temperature of low temperature protection | ℃ | 5 | 5 | 5 | 5 | 5 |
65ºC hot water output | L/min | 156 | 208 | 260 | 325 | 390 |
Dimensions | mm | 2610*1100*1950 | 3480*1100*1950 | 4350*1100*1950 | 5220*1100*1950 | 6960*1100*1950 |
Inlet/outlet connection | DN | 125 | 125 | 150 | 150 | 150 |
Heating area | m² | 3840-5760 | 5120-7680 | 6400-9600 | 8000-12000 | 9600-14400 |
Heating space | m³ | 16560-22950 | 22080-30600 | 27600-38250 | 34500-47800 | 41400-57300 |
Electric meter | A | 3-phase power meter 1.5-1.6A, metering transformer needs to be installed rationally by professional personnel | ||||
Protection grade | IP | 33 | 33 | 33 | 33 | 33 |
Heat dissipation of enclosure | % | ≤2 | ≤2 | ≤2 | ≤2 | ≤2 |
Max. volume of heating | L | 8800 | 11700 | 14700 | 18300 | 22000 |
Energy Saving
When the indoor temperature exceeds the pre-set value, the central heating boiler will be automatically turned off, thus efficiently saving more than 30% energy. And it can save energy by 20% in comparison with traditional boilers that use resistance heating method.
Constant Temperature and Comfortable Space
Water temperature can be controlled within a range of 5~90ºC, and the precision of temperature control can reach ±1ºC, providing a comfortable atmosphere for your space. Unlike air conditioning equipment, induction heating does not create an ideal environment for bacteria to grow.
No Noise
In contrast to central heating boilers using air cooling method, water cooled heating boilers are more quiet and unobtrusive.
Safe Operation
Utilizing induction heating achieves separation of electricity and water, providing a safer operation. Besides, multiple protection functions such as antifreeze protection, electricity leakage protection, short circuit protection, phase loss protection, overheating protection, overcurrent protection, overvoltage protection, undervoltage protection, self-inspection protection are equipped. Safe usage is guaranteed for 10 years.
Intelligent Control
Our induction central heating boilers can be WIFI remotely controlled by smart phones.
Easy to Maintain
Induction heating do not constitute the condition of fouling, eliminating the need for fouling removing treatment.
- Direct Installed Heating Mode
- Installation Method of Fan Coil Unit
- Idirect Heat Sink Installation
- Hot Water Storage Tank Installation
Please Contact Our Customer Service before Make a Purchase
- About Choosing Appropriate Power
Choosing a suitable boiler based on your actual heating area
For low-energy buildings, 60~80W/m² boilers are suitable;
For general buildings, 80~100W/m² boilers are suitable;
For villas and bungalows, 100~150W/m² boilers are suitable;
For those buildings where sealing performance is not well and room height is greater than 2.7m or people frequently enter, the building heat load is correspondingly increased and the power of central heating boiler should be higher. - About Installation Conditions
What are installation conditions
Take a 15kW induction central heating boiler as an example:
The cross section are of main power cable should not be less than 6mm3, main switch 32~45A, voltage 380V/50, minimum water flow of pump is 25L/min, the water pump needs to be selected according to building height. - About Accessories
What accessories are required
Since every installation site of customer is different, so that various accessories are required. We only provide central heating boilers, other accessories such as pump valve, piping and union connectors need to be purchased by customers. - About Connections For Heating
What are applicable connections for heating
BIYDA’s induction central heating boilers can be flexibly connected to floor heating system, radiator, hot water storage tank, fan coil unit (FCU), etc. - About Installation Service
Our products can be installed by our authorized local dealers. We also accept advance reservation, and we designate engineers to offer installation service and technical guidance on site.
- About Logistics
Shipping time and logistic distribution
We promise to ship our ready-to-ship products within 24 hours, and ship our made-to-order products within 7-10 days. And the logistics service is based on customers’ requirements. - About Service Life
How long is this product’s service life
BIYDA’s induction central heating boiler adopts high-frequency induction coil and industrial grade inverter, all key parts are made of imported high grade materials, its service life can reach 15 years or more.
Project: Hot water supply and space heating for Hohhot High Security Prison
Heating demand: The heating method of 3 railway stations, namely Golmud Mahai Station, Dachaidan Station and Yuqa Station, is replaced by electric energy heating instead of the previous coal-fired heating
Products used: 9 sets of 500-800kW inverter electromagnetic heating units
Introduction: These three railroad stations belong to the Qinghai-Tibet Railway at an altitude of over 3300. The total heating equipment provided by us has an installed power of over 6000KW, which enables electromagnetic heating to replace coal-fired heating, not only for environmental protection, but also to save heating costs. Our solution eventually became a demonstration project for the Qinghai-Tibet Railway system heating.
Project: Heating solution for Aishang Chancery residential district in 2020
Project Address: Gongzhuling, Jilin, China
Temperature: -20℃
Project Overview: Centralized heating for a new community with a construction area of about 100,000 square meters, with an actual heating area of about 80,000 square meters, using a valley electric storage heating solution.
Products used: 8 sets of 800KW BIYDA high quality induction heating furnace 1000 cubic meters of heat storage water tank
Heating temperature: 25℃ indoor
Operation cost: 22 RMB/sqm in heating season (lower than central heating cost)
Project: Water heating solution for Tonghua Normal College Bathhouse
Products used: 480kW inverter induction water heater
Client feedback: BIYDA inverter induction circulating hot water furnace can supply hot water steadily for a long time and guarantee the school's bathroom to achieve 12-hour hot water supply. It is convenient for teachers and students to take a bath.