High Static Pressure Duct Air Conditioner
Introduction
WARM has independently developed the first special air conditioner with multi-frequency technology. The high static pressure duct air conditioner is specially designed for factories, stations, and other large scale structures. The special design of the open, wide range and anti-condensation spherical nozzle realizes long distance air supply without air ducts, operation, or regular maintenance. The system can be conveniently installed on walls or ceilings and occupies no ground space. The unit integrates DC inverter technology to optimize its energy saving operation.
Unit model | |||||||
Power Supply | 380~415.3N ~/50HZ | 380~415.3N ~/50HZ | 380~415.3N ~/50HZ | 380~415.3N ~/50HZ | 380~415.3N ~/50HZ | ||
Refrigeration | Capacity | kW | 25.2 | 28 | 33.5 | 40 | 47 |
Power | kW | 5.8 | 6.8 | 8.5 | 10.3 | 12.1 | |
Limited charge | A | 8.8 | 10.3 | 12.7 | 16.7 | 19.8 | |
Heating | Capacity | kW | 28 | 31.5 | 37.5 | 45 | 50 |
Power | kW | 6.1 | 7.0 | 8.6 | 10.2 | 11.8 | |
Limited charge | A9.3 | 9.3 | 10.5 | 12.8 | 15.1 | 17.5 | |
Maximum power dissipation | kW | 14 | 14.2 | 15.1 | 20.1 | 21.3 | |
Compressor | Type | Fully enclosed vortex | |||||
Refrigeration oil | Brand | FVC68D | |||||
Filling volume L | 4 | 4 | 4 | 5.5 | 5.5 | ||
Fan | Type | Axial fan blade | |||||
Output power | kW | 0.75 | 0.75 | 0.75 | 0.82 | 0.82 | |
Air volume | m³/h | 11000 | 11000 | 11000 | 14000 | 14000 | |
Noise | dB(A) | ≤60 | ≤60 | ≤60 | ≤62 | ≤62 | |
Unit (W×D×H) | mm | 930×765×1680 | 930×765×1680 | 930×765×1680 | 1340×765×1680 | 1340×765×1680 | |
Packing (W×D×H) | mm | 980×810×1840 | 980×810×1840 | 980×810×1840 | 1390×810×1840 | 1390×810×1840 | |
Net weight / Gross weight | kg | 280/300 | 280/300 | 280/300 | 350/375 | 350/375 | |
Cryogen | Type | R410A | |||||
Filling amount | kg | 8.5 | 8.5 | 9 | 13 | 13 | |
Liquid tube Specification / Trachea specification | mm | Φ12.7/Φ22.2 | Φ12.7/Φ22.2 | Φ12.7/Φ22.2 | Φ12.7/Φ28.6 | Φ12.7/Φ28.6 | |
Maximum pressure of unit operation | MPa | 4.2 | 4.2 | 4.2 | 4.2 | 4.2 |
The above parameters may be changed due to the improvement of the product performance. The company reserves the right to change the product design without notice in advance. Please use the brand name parameter as the standard.
Features:
1. An external machine can connect multiple internal machines with various combinations.
2. The high static pressure wind pipe machine has a long distance cooling medium pipe, the longest pipe length can reach 100m, and the drop between the indoor machine can reach 50m.
3. A new type of R410A high efficient green medium is used to reduce pollution.
4. The new intelligent frost technology can automatically diagnose frost, determine the time of defrosting, accurately reflect the frosting condition, effectively eliminate the mistaken judgment of frost, improve the performance and reliability of the unit. It can increase the heat of air conditioning by 20%, reduce the number of frost by 70%, which makes the room temperature change smoothly, and greatly improve the heating efficiency of the air conditioning at low temperature.
5. Automatic unloading technology: the unloading valve in refrigeration system realize automatic unloading when the air conditioning in the harsh environment of high temperature, reduce pressure of the high-pressure side of the refrigeration system without downtime, which greatly reduces the frequent start of the unit, improve the air conditioning load resisting ability and reliability.
6. Special requirements for high-speed nozzle and traditional air conditioner: combination high speed nozzle and DC frequency conversion technology innovatively, which provides more choices for large space air conditioning design. It is very suitable for factories, gymnasiums, exhibition halls, large supermarkets and other occasions.
7. The vent can connect the function box with special requirements such as silence, dust removal, sterilization and oxygen increase. The air outlet can connect the filter and other functional boxes (optional parts), which can be connected directly.