JDSU FI-60 Optical Fiber Identifier

JDSU FI-60 Optical Fiber Identifier
JDSU FI-60 Optical Fiber Identifier
Request a Quote
JDSU FI-60

When installing, testing or troubleshooting fiber networks, technicians usually have to disconnect active fibers, and this is a major cause for service interruption. Given this, the JDSU FI-60 optical fiber identifier is developed to allow technicians to detect optical signals without disconnecting fibers, and its unique SafeChekTM easy-pull trigger system ensures safe and repeatable engagement with most types of optical fibers, thereby eliminating the need of changing out expensive dies.

On the other hand, this optical fiber identifier could be retrofitted in to an optical power meter (OPM) conveniently, so technicians don't need to carry too many tools with them during work. More importantly, the retrofit process is quite simple: remove the head attachment, connect corresponding adapter (2.5mm or 1.25mm) and insert a connector.

Feature
1. This live fiber identifier avoids network downtime and fiber damage due to the repeatable SafeChekTM system, and it uses a single head, which is applicable for 250μm to 3mm jacketed fibers, to finish testing in a short time.
2. Thanks to the ergonomic design, our fiber identifier realizes easy cable access under different environments, and the integrated ambient light shield not only enhances test reliability, but also avoids false reading.
3. After converting into an OPM, FI-60 optical fiber identifier is able to store and recall 100 power measurement results which are acquired at different wavelengths, and it could measure absolute (dBm) and relative (dB) power. Additionally, test results can be delivered to a PC via USB connection.
4. If connected to FiberChek2, this multi-functional fiber test instrument could provide fiber inspection, power testing and reporting capabilities.

Application
1. Quickly identify live optical signals on fiber cables without disrupting network traffic
2. Take optical power measurements for all single mode and multimode conncetors
3. Integrate with FiberChek2 software for integrated testing

Technical Data of JDSU FI-60 Optical Fiber Identifier

General
Power supply2×alkaline AA battery
Wavelength range780 to 1800nm
Battery life>70 hours
USB type2.0
Screen size (W×H)3.7×3.1cm
Storage temperature-20℃ to 70℃
Operating temperature0℃ to 50℃
Optical Fiber Identifier
Size216×60×38mm
Weight135g with two AA batteries
Detection sensitivity-20dBm at 1310nm, -30dBm at 1550nm
Typical insertion loss<0.2dB at 1310nm, <2dB at 1550nm
Detected wavelength range850-1700nm
Detected tone270Hz, 330Hz, 1kHz, 2kHz
Standard cable diameter range250μm to 3mm
Optical Power Meter
Size171×42×25mm
Weight100g with two AA batteries
Connector input1.25mm and 2.5mm
Measurement unitdB, dBm
Detectable optical power range-65dBm to 10dBm
Max. permitted input power 23dBm
Intrinsic uncertainty±0.20dB (±5%)
Linearity±0.06dB (-50dBm to 5dBm)
Standard wavelength850/980/1300/1310/1490/1550/1625nm
Wavelength and modulation270Hz, 330Hz, 1kHz, 2kHz
1300/1310/1490/1550/1625nm: -60dBm to 10dBm
850/980nm: -55dBm to 10dBm

Standard Package
1. JDSU FI-60 optical fiber identifier (with 2.5mm and 1.25mm OPM connectors)
2. USB cable
3. Software
4. Carrying case

Related products
Send Message
Other Products
Inquiry
Inquiry