Cummins Diesel Generator Sets
Our Cummins diesel generator sets are available in 50HZ, 1500RPM and 60HZ, 1800r/min. Normal power of the generating system is varied from 20 kW to 1100 kW. Alternator is supplied by internationally renowned providers such as Faraday, Engga and Stamford, etc.
We adopt Cummins engine, for superior stability and dependability. Cummins is the global leading manufacturer of power generation equipment, and is presented in 137 countries around the world with over 680 distributors and 5,000 service centers. Our Cummins diesel generator sets are amazingly backed by these facilities and you can enjoy unbeatable service experience.
Advantages
1. The engine unit in this onsite diesel generator is endowed with robust cast iron enclosure, forged structure and rounded quenched crankshaft, thus realizing exceptional strength and stable performance.
2. The starting system utilizes DC 24V. Charging engine is available. Electronic governor delivers outstanding speed control exceeding standards of GB/T2820.5 and ISO8525-5.
3. Our diesel generator sets involve the utilization of patented PT fuel system from Cummins. Ingenious protection system, low pressure oil supply and extra-high jetting pressure (100-140Mp) are responsible for impressive atomization and complete combustion, as well as meeting norms of Euro II, Euro III, EPA and CARB.
Specifications
Model | ||||||||||||||||||||||||||
GensetPower | Prime Power (kW) | 20 | 30 | 45 | 75 | 90 | 100 | 110 | 120 | 140 | 160 | 200 | 220 | 240 | 280 | 300 | 330 | 360 | 400 | 420 | 500 | 600 | 728 | 800 | 1000 | 1100 |
Standby Power (kW) | 22 | 33 | 50 | 82.5 | 100 | 110 | 121 | 132 | 154 | 176 | 220 | 242 | 264 | 308 | 330 | 363 | 396 | 440 | 462 | 550 | 660 | 800 | 880 | 1100 | 1210 | |
Engine | Cummins | 4B3.9-G | 4BT3.9-G | 4BTA3.9-G | 6BT5.9-G | 6BTA5.9-G | 6BTAA5.9-G | 6CT8.3-G | 6CTA8.3-G | 6CTA8.3-G | 6CTAA8.3-G | 6LTAA8.9-G | NTA855-G1A | MTAA11-G3 | NTA855-G4 | NTAA855-G7 | NTAA855-G7A | KTA19-G3 | KTA19-G4 | KTAA19-G5 | KTAA19-G6A | KTA38-G2 | KTA38-G2A | KTA38-G5 | KTA50-G3 | KTA50-G8 |
Generator | Stamford | PI144E | UCI224C | UCI224E | UCI274C | UCI274D | UCI274E | UCI274E | UCI274F | UCI274G | UCI274H | UCDI274K | HCI4D | HCI4ES | HCI4E | HCI4FS | HCI4F | HCI5C | HCI5C | HCI5D | HCI5FS | LVI6B | LVI6D | LVI6E | LVI6G | PI734B |
Faraday | FD1F-4 | FD1J-4 | FD2C-4 | FD3A-4 | FD3B-4 | FD3C-4 | FD3DS-4 | FD3D-4 | FD3EM-4 | FD3F-4 | FD3H-4 | FD4MS-4 | FD4M-4 | FD4LS-4 | FD4L-4 | FD4LP-4 | FD5S-4 | FD5M-4 | FD5MP-4 | FD5L-4 | FD6AS-4 | FD6B-4 | FD6C-4 | FD6E-4 | FD7A-4 | |
Engga | - | - | EG225S-50N | EG225L-80N | EG225L-90N | EG225L-100N | EG225L-120N | EG225L-120N | EG280M-140N | EG280M-160N | EG280L-200N | EG280L-230N | EG280L-250N | EG315M-280N | EG315M-300N | EG315M-320N | EG315L-360N | EG315L-400N | EG315M-450N | EG355L-500N | EG355L-600N | EG400M-720N | EG400L-800N | EG400L-1000N | EG450S-1200N | |
Fuel Consumption (g/KWh) | 228 | 214 | 216 | 214 | 211 | 208 | 210 | 215 | 215 | 205 | 197 | 190 | 188 | 200 | 207 | 207 | 205 | 203 | 207 | 206 | 213 | 199 | 202 | 254L/H | 289L/H | |
Voltage (V) | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | 400/230 | |
Steady-State Voltage Regulation | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | ≤±1% | |
Transient Voltage Deviation | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | ≤±20% | |
Voltage Recovery Time | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | ≤1s | |
Voltage Fluctuation | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | |
Steady-State Frequency Regulation | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | ≤1.5% | |
Transient Frequency Deviation | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | ≤-10%-12% | |
Frequency Recovery Time | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | ≤5s | |
Frequency Fluctuation | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | |
Open-Frame GensetDimension (L×W×H) (mm) | 1760×760×1380 | 1760×760×1380 | 1860×760×1380 | 2300×830×1700 | 2300×830×1700 | 2350×830×1700 | 2430×945×1850 | 2430×945×1850 | 2430×945×1850 | 2460×960×1850 | 2530×960×1850 | 3200×980×1720 | 3100×1150×1780 | 3030×1100×1900 | 3250×1160×1850 | 3250×1160×1850 | 3400×1380×2050 | 3400×1360×2050 | 3720×1530×2100 | 3700×1570×2080 | 4370×2060×2430 | 4350×2060×2450 | 4350×2060×2150 | 4950×2060×2350 | 4950×2200×2480 | |
Open-Frame GensetWeight (kg) | 710 | 880 | 960 | 1290 | 1320 | 1330 | 1670 | 1690 | 1690 | 1920 | 2010 | 2650 | 2470 | 2950 | 3230 | 3230 | 4170 | 4230 | 4450 | 4770 | 6900 | 7120 | 8160 | 9500 | 10900 | |
Genset with Sub Base Tank Dimension (L×W×H) (mm) | 1760×760×1380 | 1760×760×1380 | 1860×760×1380 | 2300×830×1700 | 2300×830×1700 | 2350×830×1700 | 2430×945×1850 | 2430×945×1850 | 2430×945×1850 | 2460×960×1850 | 2530×960×1850 | 3200×980×1720 | 3100×1150×1780 | 3030×1100×1900 | 3250×1160×1850 | 3250×1160×1850 | 3400×1380×2050 | 3400×1360×2050 | 3720×1530×2100 | 3700×1570×2080 | 4370×2060×2430 | 4350×2060×2450 | 4350×2060×2150 | 4950×2060×2350 | 4950×2200×2480 | |
Weight of Gensetwith Sub Base Tank (kg) | 730 | 900 | 980 | 1310 | 1340 | 1360 | 1700 | 1720 | 1720 | 1950 | 2060 | 2700 | 2520 | 3000 | 3280 | 3280 | 4200 | 4280 | 4500 | 4820 | 6950 | 7200 | 8250 | 9600 | 11000 | |
Super Silent GensetDimension (L×W×H) (mm) | 2290×1060×1680 | 2290×1060×1680 | 2440×1060×1680 | 2810×1140×1830 | 3250×1170×1800 | 3250×1170×1800 | 3250×1170×1800 | 3250×1170×1800 | 3250×1170×1800 | 3590×1250×2050 | 3590×1250×2050 | 3700×1350×2050 | 3890×1460×2150 | 4230×1460×2150 | 4230×1460×2150 | 4230×1460×2150 | 4630×1660×2250 | 4630×1660×2250 | 4630×1860×2250 | 5030×1860×2550 | 6060×2450×2600 | 6060×2450×2600 | 6060×2450×2600 | 6060×2450×2600 | 6060×2500×3000 | |
Weight of Super Silent Genset (kg) | 1250 | 1350 | 1450 | 1800 | 2050 | 2140 | 2350 | 2485 | 2485 | 2690 | 2940 | 3250 | 3770 | 4330 | 4520 | 4520 | 5600 | 5700 | 6000 | 6500 | 11500 | 12200 | 13000 | 15000 | 16500 | |
Trailer MountedGenset Dimension (L×W×H) (mm) | 2860×1640×2320 | 2860×1640×2320 | 3010×1640×2320 | 3390×1720×2470 | 4030×2140×2510 | 4030×2140×2510 | 4030×2140×2510 | 4030×2140×2510 | 4030×2140×2510 | 4390×2150×2760 | 4390×2150×2760 | 4500×2150×2760 | 4680×2440×2880 | 5030×2440×2880 | 5030×2440×2880 | 5030×2440×2880 | 5440×2540×3100 | 5440×2540×3100 | 5440×2540×3100 | - | - | - | - | - | - | |
Weight of Trailer Mounted Genset(kg) | 1850 | 1950 | 2100 | 2450 | 2950 | 3150 | 3400 | 3430 | 3430 | 3840 | 3990 | 4500 | 5130 | 5690 | 5880 | 5880 | 7050 | 7150 | 7250 | - | - | - | - | - | - | |
Note: Diesel generator sets in 60HZ and 1800r/min are available upon request. | ||||||||||||||||||||||||||