Hook-Up Wire, UL1571

Hook-Up Wire, UL1571
Request a Quote

About UL1571
Manufacture standard: UL758
Rated voltage: 30Vac
Temperature range: -40 to 80℃
Conductor: Bare copper
Insulator: PVC
Flame retardant performance: Passing UL VW-1 and CSA FT1 vertical flame tests
Environmental protection: ROHS standard
Color: Black, brown, red, orange, yellow, green, blue, purple, gray and white.
Application: Internal wiring and electronic equipment

Technical Parameters of UL Hook up Wire
Conductor Insulator Hook up wire structure Protective cover Conductor resistance (Bare copper) Standard length
Wire gauge Structure Diameter Nominal thickness Min. thickness Nominal external diameter Number of wires/Wire diameter Nominal thickness Nominal external diameter Max. value (20℃) English unit Metric unit
AWG Number of wires/Wire diameter (mm) mm mm mm mm mm mm mm Ω /km FT m
30 7/0.10 0.30 0.38 0.33 1.10±0.1 32/0.1 0.4 2.1 354 2000 610
28 7/0.127 0.38 0.38 0.33 1.20±0.1 34/0.1 0.4 2.2 223
26 7/0.16 0.48 0.38 0.33 1.30±0.1 38/0.1 0.4 2.3 140
24 11/0.16 0.61 0.38 0.33 1.40±0.1 42/0.1 0.4 2.4 87.6
22 17/0.16 0.76 0.38 0.33 1.60±0.1 40/0.12 0.4 2.7 55.4
20 26/0.16 0.94 0.38 0.33 1.80±0.1 45/0.12 0.5 3.10 34.6
18 41/0.16 1.18 0.38 0.33 2.0±0.1 51/0.12 0.5 3.3 21.8
16 26/0.254 1.50 0.38 0.33 2.30 ± 0.10 55/0.12 0.5 3.6 13.7
Notes: 1. We can manufacture the hook-up wire according to client's drawing or sample.
2. The structure of conductor is either solid or stranded. For example, "7/0.10" means the conductor is stranded by 7 wires and the wire has a diameter of 0.10 mm.
Related products
Send Message
Other Products
Inquiry
Inquiry