AC Current Transducers, BA series

AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
AC Current Transducers, BA series
Request a Quote

BA series AC current transducers apply the principle of electromagnetic induction to measure the AC in the power grid in real time, and adopt precise constant current technology and linear temperature compensation technology to isolate and convert it into standard DC signal output. These AC current transducers are powered by 24v or 12v safe voltage.

AC Current Transducer, BA05-AI/I

Technical Data
  • Input: 0~(0.5~10)A AC
  • Output: 4~20mA/0~5V DC
  • Power supply: 12V/24V DC
  • Perforation Hole Size: φ5mm
  • Application: paired with PLC for industrial automation
  • Accuracy: Class 0.5
  • Response time: ≤350ms
  • Installation: 35mm DIN rail/screw fixed
  • Standard & Certificate: CE, TüV

AC Current Transducer, BA10-AI/I

Technical Data
  • Input: 0~(8~50)A AC
  • Output: 4~20mA/0~5V DC
  • Power supply: 12V/24V DC
  • Perforation hole size: φ10mm
  • Application: paired with PLC for industrial automation
  • Accuracy: Class 0.5
  • Response time: ≤350ms
  • Installation: 35mm DIN rail/screw fixed
  • Standard & Certificate: CE, TüV

AC Current Transducer BA20-AI/I

Technical Data
  • Input: 0~(40~200)A AC
  • Output: 4~20mA/0~5V DC
  • Power supply: 12V/24V DC
  • Perforation hole size: φ20mm
  • Application: paired with PLC for industrial automation
  • Accuracy: Class 0.5
  • Response time: ≤350ms
  • Installation: 35mm DIN rail/screw fixed
  • Standard & Certificate: CE, TüV

AC Current Transducer, BA50-AI/V

Technical Data
  • Input: 0~(60~600)A AC
  • Output: 4~20mA/0~5V DC
  • Power supply: 12V/24V DC
  • Perforation hole size: φ50mm
  • Application: paired with PLC for industrial automation
  • Accuracy: Class 0.5
  • Response time: ≤350ms
  • Installation: 35mm DIN rail/screw fixed
  • Standard & Certificate: CE, TüV

AC Residual Current Transducer, BA50L-AI/I

Technical Data
  • Input: 0~(0.1~1)A AC
  • Output: 4~20mA/0~5V DC
  • Power supply: 12V/24V DC
  • Perforation hole size: φ50mm
  • Application: paired with PLC for industrial automation
  • Accuracy: Class 0.5
  • Response time: ≤350ms
  • Installation: 35mm DIN rail/screw fixed
  • Standard & Certificate: CE, TüV