450/750V Copper Conductor PVC Insulated and Sheathed Flexible Cord
Flexible Stranded Copper Conductor/ Stranded Copper Conductor/ Solid Copper Conductor
Electric Wire Characteristics:
1). Rated voltage U0/U 300/500V and 450/750V
2). The long-term permissible temperature of cable: BV-105 below 105°C, and the other below 70°C.
3). Conductor maximum short circuit (no more than 5 seconds) temperature shall not be higher than 160°c. 4). The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0°c.
5). The bend radius: the external diameter of cable <25mm, and the bend radius is above 4 times of the external diameter of cable. And the other is above 6 times of the external diameter of cable.
6). Perfect chemical stability, resistance to acid, alkalis, grease and organic solvents. Non-flammable.
7). Light weight, perfect bending properties, installed and maintained easily and conveniently.
8). Insulation sheath material and color: PVC in any color as required.
9). Type: Single or twin cables with different colors provided
No. | Size | Specification | Length per roll |
PVC insulated non-sheathed copper wires BV (450-750 Voltage) | |||
1 | 1.5 mm2 | 1×1.38 mm2 | 100 m |
2 | 2.5 mm2 | 1×1.78 mm2 | 100 m |
3 | 4 mm2 | 1×2.25 mm2 | 100 m |
4 | 6 mm2 | 1×2.76 mm2 | 100 m |
5 | 10 mm2 | 7×1.35 mm2 | 100 m |
6 | 16 mm2 | 7×1.70 mm2 | 100 m |
7 | 25 mm2 | 7×2.14 mm2 | 100 m |
PVC insulated PVC/XLPE sheathed Twin cables with/without earth BVVB (300-500 Voltage) | |||
8 | 2×1 1 mm2 | 2×1.13 1.13 mm2 | 100 m |
9 | 2×1.5 1 mm2 | 2×1.38 1.13 mm2 | 100 m |
10 | 2×2.5 1.5 mm2 | 2×1.78 1.38 mm2 | 100 m |
11 | 2×4 2.5 mm2 | 2×2.25 1.78 mm2 | 100 m |
12 | 2×6 4 mm2 | 2×2.76 2.25 mm2 | 100 m |
13 | 2×10 4 mm2 | 2×7×1.35 2.25 mm2 | 100 m |
14 | 2×16 6 mm2 | 2×7×1.70 2.76 mm2 | 100 m |
PVC insulated non-sheathed Multi flexible wires BVR (450-750 Voltage) | |||
15 | 1.5 mm2 | 7×0.52 mm2 | 100 m |
16 | 2.5 mm2 | 19×0.41 mm2 | 100 m |
17 | 4 mm2 | 19×0.52 mm2 | 100 m |
18 | 6 mm2 | 19×0.63 mm2 | 100 m |
19 | 10 mm2 | 49×0.52 mm2 | 100 m |
20 | 16 mm2 | 49×0.63 mm2 | 100 m |
PVC insulated PVC/XLPE sheathed copper cables (Lower than 1000 Voltage) | ||
No. | Size | Specification |
21 | 3×2.5 mm2 | 3×1.78 mm2 |
22 | 3×4 mm2 | 3×2.25 mm2 |
23 | 3×4 1×2.5 mm2 | 3×2.25 1×1.78 mm2 |
24 | 3×4 2×2.5 mm2 | 3×2.25 2×1.78 mm2 |
25 | 3×6 mm2 | 3×2.76 mm2 |
26 | 3×6 1×4 mm2 | 3×2.76 1×2.25 mm2 |
27 | 3×6 2×4 mm2 | 3×2.76 2×2.25 mm2 |
28 | 3×10 mm2 | 3×7×1.35 mm2 |
29 | 3×10 1×6 mm2 | 3×7×1.35 1×2.76 mm2 |
30 | 3×10 2×6 mm2 | 3×7×1.35 2×2.76 mm2 |
31 | 3×16 mm2 | 3×7×1.70 mm2 |
32 | 3×16 1×10 mm2 | 3×7×1.70 1×7×1.35 mm2 |
33 | 3×16 2×10 mm2 | 3×7×1.70 2×7×1.35 mm2 |
34 | 3×25 1×16 mm2 | 3×7×2.14 1×7×1.70 mm2 |
35 | 3×25 2×16 mm2 | 3×7×2.14 2×7×1.70 mm2 |
36 | 3×35 1×16 mm2 | 3×7×2.52 1×7×1.70 mm2 |
37 | 3×35 2×16 mm2 | 3×7×2.52 2×7×1.70 mm2 |
38 | 3×50 1×25 mm2 | 3×10×2.52 1×7×2.14 mm2 |
39 | 3×50 2×25 mm2 | 3×10×2.52 2×7×2.14 mm2 |
40 | 3×70 1×35 mm2 | 3×14×2.52 1×7×2.52 mm |
41 | 3×70 2×35 mm2 | 3×14×2.52 2×7×2.52 mm2 |
42 | 3×95 1×50 mm2 | 3×19×2.52 1×10×2.52 mm2 |
43 | 3×95 2×50 mm2 | 3×19×2.52 2×10×2.52 mm2 |