IPKIS provides PV combiner boxes crafted for 1500V DC solar distribution systems. Tailored for 16 to 24 parallel voltage inputs, they ensure safety with a robust photovoltaic protection system—featuring dedicated DC input fuses, a plastic shell DC output circuit breaker, and a specialized lightning protection module.

Furthermore, customization options include anti-backflow diodes, meeting elevated distribution demands for solar businesses.

Technical Data
Model PVC-16/1500V PVC-20/1500V PVC-24/1500V
PV Array System Voltage (V, DC) 1500v
Maximum Number of Parallel Inputs in PV Array 16 20 24
Number of Output Channels 1
Maximum Input Current per Channel (A) 35
Positive and Negative Wire Diameter for String Inputs (mm²) 4-6
Positive and Negative Wire Diameter for Outputs (mm²) 2*185-300 (Aluminum alloy cable)
Ground Wire Diameter (mm²) ≥16
Dimensions (Width*Height*Depth, mm) 733*733*260 930*730*260 933*733*260
Mounting Dimensions (mm) 590*672 816*701 790*672
Protection Features
PV-dedicated DC Input Fuse
Rated Voltage: 1,500V
Rated Current: 15-35A
Breaking Capacity: 20kA
PV-dedicated DC Output Circuit Breaker in Plastic Enclosure Rated Voltage: 1,500V
Rated Current: 400-630A
Equipped with auxiliary contact for output signal
PV-dedicated Lightning Protection Module In: 20kA
Imax: 40kA
Ups: 4kV
Anti-backflow Diode Optional
Environment Conditions
Protection Rating IP67
Temperature and Humidity Please provide specific details if the device will be used in areas with gases.
Temperature Range: -25°C to 50°C
Storage Temperature Range: -40°C to 70°C
Humidity: 0% to 95%
No condensation, no corrosive elements
Altitude ≤2,000m For the operating location with an altitude higher than 2,000m, we offer customized components.
Salt Spray Resistance Salt spray test
Standard: 336h
Optional: 500h
Smart Communication
Measurement Hall Isolation Measurement
Communication Port Equipped
Communication Protocol RS 485/Modbus-RTU
Functions Measurement of string current, total voltage, and temperature inside the box
Status monitoring of circuit breaker status, lightning arrester
Alerting and debugging.
Power Supply Self-supply
Schematic Diagram
Safety
Busbar Overlapping large-section nickel-coated copper bars
Protection PC insulated enclosure
Electrical Clearance / Creepage Distance ≥14mm/ ≥25mm
Insulation Resistance >20MΩ
AC Withstand Voltage AC4400V,1MIN
Enclosure (with Rain Cover) PC transparent shell
Enclosure Material SMC
Protection Rating IP67
Terminal Block PA66, IP68
Cable Connector MC4, IP67 (customizable)
Mounting Method Vertical (also available for horizontal mounting)