Passive House Fresh Air Ventilation Air Conditioner

Passive House Fresh Air Ventilation Air Conditioner
Request a Quote

Introduction
This fresh air heat recovery system can achieve ventilation, heat recovery and filtration. Not only does it achieve a basic ventilation function, but the heat recovery can exchange stale indoor air with a filtered indoor fresh air. The heat recovery process will mediate the temperature of the outdoor fresh air closely to that of the indoor, which will let the residents feel comfortable as well as save energy and protect the environment.

The filtration is specially designed for hazy weather to filter the inhalable particulate matter to decrease the PM 2.5 and control CO2 by using a high level filter capacity to ensure the safety of indoor air, which builds a healthy environment with constant temperature, constant humidity and constant oxygen all day.

Parameters
Model No. WMZW16 WMZW30 WMZW60 WMZW90
Unit Information Cooling capacity KW 10 20 40 60
Rated airflow m3/h 1600 3000 6000 9000
Motor power KW 2.6 4.8 6.6 8.6
Humidification amount Kg/h 6 12 25 30
Energy recovery rate % 75
Power supply Ph/v/Hz 3/380/50
Air filter G4 H11
Fresh air Fresh air volume m3/h 1600 3000 6000 9000
Ext. Static Pressure of fresh air system Pa 150 150 250 250
Exhaust air Exhaust airflow m3/h 1600 3000 6000 9000
Ext. Static Pressure of Exhaust air system Pa 150 150 250 250
Energy Saver Double rotary wheel type heat exchanger
Dimension L 4900 4900 6000 6000
W 1200 1200 2000 2000
H 1700 1700 2100 2100
Weight Kg 680 720 1200 1400

Features
1. The air conditioner is specially designed for passive buildings to provide a system solution of temperature, humidity, CO2 content, oxygen content and PM10 and PM2.5 indexes.

2. In addition to the ordinary central air conditioning function, the air conditioner has a fresh air and exhaust function to ensure the air freshness of indoor closed space.

3. The fresh air and exhaust system uses an energy recovery device, and uses the dual system design of a total heat exchanger and sensible heat exchanger, which can meet the temperature recovery requirements and humidity recovery requirements in different seasons respectively. The rate of heat recovery can reach above 75% to make the energy recovery more sufficient.

4. The air conditioner uses a unique aeration design. When the outdoor air quality is poor, the air conditioner will automatically change the new exhaust function into the indoor oxygen increase mode to control the indoor CO2 content and PM10, PM2.5 concentration, which ensures the comfort of inhabitant.

5. Intelligent respiratory system
a. Multi system with high integration: The intelligent air control system consists of a fresh air total heat exchanger, dust filtering system, environmental monitoring system and intelligent control system and more.

b. Integrated control design: The intelligent control system of the independent patent has unified control on the air conditioning system, fresh air total heat exchange system and air purification system. The system monitors the data according to the environment of different functional partitions to be efficient.

6. Efficient zoning control: The control system will carry out multi system automatic linkage to monitor data based on indoor and outdoor environmental conditions.

Customization
Units with various functions can be customized according to various requirements.