Cyclic Corrosion Chamber
Request a Quote
Cyclic corrosion chamber is used for imitating corrosive environment to carry out cyclic corrosion testing. The imitated environment is more severe than that of we usually meet. The corrosion test chamber can test products in environmental conditions combined with salt smog, dry, humidity and low temperature.
This testing equipment is specially designed for testing products used in intensely changeable environments, such as parts of automobile navigation equipment, camera equipment, building material and electroplate coating.
Features
- Adopting LCD color touch screen controller (SAMWOM TECH TEMI2500), all temperature humidity test curve can be recorded.
- Control method: temperature programmable alternating control, humidity programmable alternating control and temperature/humidity programmable alternating control.
- Capacity of programmable group: 140 Patterns (group) 1400 Steps (section). There can be a maximum of Repeat 99 section for every programmable group.
- Mode execution time for every section can be between zero to 999 hours and 59 minutes.
- 1-999 circles of partial circulation or 1-999 circles of complete circulation can be set for every group.
- Memory function: In case of a power failure, the testing machine can continue with the unfinished test as soon as power is recovered.
- Can be connected with computer through RS2321RS-485 po
- Controller has SD storage card with 2G capacity, enabling it to record test data of two years.
Technical Parameters
Model | CZ-90D | CZ-120D | CZ-160D | CZ-200D |
Internal Dimension WxHxD(mm) | 900x620x600 | 1200x760x 1000 | 1600x760x1000 | 2000x760x 1100 |
External Dimension WxHxD(mm) | 2450x1553x1430 | 2830x1560x1830 | 3230x 1560x 1830 | 3630x1560x1930 |
Temperature Range | RT-80℃/-10℃-80℃ | |||
Humidity Range | 20%-98% | |||
Analytic Accuracy/Evenness Degree of Temperature and Humidity | 0.1℃;0.1%R.H./±1.0℃; ± 3.0%R.H. | |||
Control Accuracy/ Stability of Temperature and Humidity | ±1.0℃; ±2.0%R.H./±0.5℃; ±2.0%R.H. | |||
Lab Temperature | Saline testing method(NSS ACSS)35℃ ± 1℃/Corrosion-resistant testing method(CASS)50℃ ± 1℃ | |||
Pressure Pot Temperature | Saline testing method(NSS ACSS)47℃± 1℃/Corrosion-resistant testing method(CASS)63℃± 1℃ | |||
Saline Temperature | 35℃ ± 1℃ 50℃ ± 1℃ | |||
Saline Concentration | Sodium chloride solution with 5% concentration or 0.26g copper chloride is added to each liter 01 sodium chloride solution with 5% concentration | |||
Compressed Air Pressure | 1.00± 0.01kgl/cm² | |||
Spray Volume | 1.0-2.0mI /80cm²/h (at least collect 16 hours and take the average value) | |||
PH Value | 6.5-7.2 3.0-3.2 | |||
Spray Method | Continuous spraying/intermittent spray | |||
Power | AC380V3φ 20A | AC380V3φ23A | AC380V3φ25A | AC380V3φ30A |
Notes: The dimensions of the testing room are customized to satisfy the customers' requirements
Related products
Send Message
Other Products
Most Recent
More
Other Products
Videos