Direct Acting Solenoid Valve

Direct Acting Solenoid Valve
Direct Acting Solenoid Valve
Direct Acting Solenoid Valve
Direct Acting Solenoid Valve
Request a Quote
Direct Acting Solenoid Valve SV1.6, SV2, SV3 Series

Introduction
The SV1.6, SV2, and SV3 direct acting solenoid valves feature a compact structure, easy installation and maintenance, and operate quickly.

This series is widely used in refrigeration, pneumatic and hydraulic systems. They utilize a fully closed magnetic coil and DIN international standard electric plug, ensuring the excellent insulation, water and moisture resistance, vibration resistance and corrosion resistance.

Operating Principle
The pull of the solenoid coil opens the valve port directly by lifting the seat disc off of the valve seat. While energy is lowered in the coil, the plug stem will drop and close the valve port due to the spring force and its weight.

Type & Data
Connection form Model Connection dimension Kv value (m3/h) Opening diff. pressure (MPa) Dimension (mm)
(mm) (in.) Min. Max.
A.C. D.C. Length Width Height
Flare SAE NSV1.6 Φ6 1/4 0.15 0 3 2.6 48 33 55
SV2 Φ6 1/4 0.16 70 30 75
SV3 Φ6 1/4 0.23 2.1 1.7
Solder ODF SV1.6W Φ6 1/4 0.15 3 2.6 80 33 55
SV2W Φ6 1/4 0.16 117 30 75
SV3W Φ6 1/4 0.23 2.1 1.7
Φ8 5/16
Φ10 3/8
Internal thread NSV1.6A 3/8 0.15 3 2.6 30 33 55
NSV1.6B 1/8 (NPTF)

The Kv value is the water flow at m3/h at a pressure drop across a value of 0.1MPa, ρ=1000kg/m3.
W= Solder ODF, A and B = different valve bodies, K = normal opened valve bodies

Direct Acting Solenoid Valve NSV2.2A Series

Introduction
The NSV2.2A direct acting solenoid valves feature a compact structure, streamlined design, easy installation and maintenance, and operate quickly. This series is widely used in refrigeration, pneumatic and hydraulic systems. These valves use fully closed magnetic coils and DIN international standard electric plugs, making them known for the excellent insulation, waterproof, moisture resistance, vibration resistance and corrosion resistance.

Operating Principle
The pull of the solenoid coil opens the valve port directly by lifting the seat disc off the valve seat. While energy is low in the coil, the plug stem will drop and close the valve port due to the spring force and weight.

Type & Data of Direct Acting Solenoid Valve NSV2.2A Series
Connection form Model Connection dimension Kv value (m3/h) Opening diff. pressure (MPa) Dimension (mm)
(mm) (in.) Min. Max.
A.C. D.C. Length Width Height
Internal thread NSV2.2A RC1/4'' 0.09 0 2.1 34 30 65

The Kv value is the water flow at m3/h at a pressure drop across a value of 0.1MPa, ρ=1000kg/m3.
W= Solder ODF, A and B = different valve bodies, K = normal opened valve bodies