ADS Series Hall-Effect Rotary Angle Displacement Sensor with Hollow Shaft

ADS Series Hall-Effect Rotary Angle Displacement Sensor with Hollow Shaft
Request a Quote

Yuanben ADS series rotary angle displacement sensors may potentially be mounted adjacent to the pedal to measure how far the pedal is depressed or released by the operator. The sensor senses the change in pedal position and sends a signal to the engine control unit to either increase or reduce the flow of gasoline and air across the throttle plate, as needed.

Yuanben provides non-contact operation, low torque actuation and reduces worn-out mechanisms. Wider sensing range and multi factory-set operating ranges (60°, 90°, 120°, 180°, 270°, 360°) allow the customer to select the range of travel needed for the application, and used in harsh transportation and industrial applications at a competitive cost.

Features
  • True, non-contact operation
  • Solid-state Hall-effect technology
  • Rugged IP69K-sealed package with integral connector
  • Automotive-grade EMI/EMC testing, integrated reverse polarity, and short circuit protection
  • Industry-standard AMP termination, North American or European pin-out styles, and compact seal
  • Operating ranges up to 360°
Applications
    Transportation
  • Position and movement detection of pedals, throttles, gear shift, levers, steering, linkages, and hitches (trucks, buses, off-road vehicles, cranes, and industrial/construction/agricultural vehicles and equipment)
  • Suspension/kneeling position (buses, trucks)
  • Tilt/trim position (boat engines, tilling equipment)
    Industrial
  • Valve control
  • HVAC damper control
  • Irrigation equipment pivot control
Technical Parameters
Type ADS Series (Low Voltage) ADS Series (High Voltage)
Supply Voltage 5 ±0.5 VDC 10VDC to 30VDC
Supply Current Normal 20 mA max 20 mA max.
During output to ground short 25 mA max 25 mA max.
Output Standard 0.5 VDC to 4.5 VDC ratio-metric 0.5 VDC to 4.5 VDC ratio-metric
Inverted 4.5 VDC to 0.5VDC ratio-metric 4.5 VDC to 0.5 VDC ratio-metric
Output Signal Delay 4 ms typical 4 ms typical.
Reverse Polarity Protection 10 VDC -10 VDC
Over-voltage Protection 10 VDC 10VDC
Output to Ground Short Circuit Continuous Continuous
Resolution 12 bit 12 bit
Output Load Resistance (pull down to ground) 10 kOhm typical
EMI Radiated immunity 100 V/m per IS011452-2 from 200 MHz to 1000 MHz
Conducted immunity 100 mA BCI per ISO11452-4 from 1 MHz to 200 MHz
Expected Life Infinite rotation
Air Gap Bare magnet actuator 3 mm ±0.5 mm [0.12 in ±0.02 in]
Housed magnet actuator 2 mm ±0.5 mm [0.08 in±0.02 in]
Misalignment 2 mm [0.08 in]max.
Material Magnet NdFeB
Sensor housing PBT plastic
Housed magnet overmold PPS plastic
Housed magnet Brass
Mating Connector AMP Super-seal 282087-1
Mechanical End Stop No