150°C Vacuum Oven
Request a Quote
Battery dry chambers are used for quick drying of lithium battery cells. This battery dryer chamber is standard designed drying equipment according to the requirements for vacuum, dimension, capacity and operating temperature in the lithium battery industry.
We offer clients 3 types of battery dry chambers; please contact us for more specific information.
ZKCO-2F-3D 150°C Vacuum OvenModel | |
Internal Dimension | 3×260(H)×800(W)×600(D)mm |
External Dimension | 1800(H)×1350(W)×1080(D)mm |
Principle | Adopts special purpose detector: vacuum degree (-95KPA) or Nitrogen (-18KPA), the output signal is sent to PLC which can finish: vacuum supply-nitrogen filling-vacuum supply-nitrogen filling (recycling) |
Main Parameters | 1: Independent temperature control for 3 chambers. |
2: Temperature range: room temperature~150℃ | |
3: Vacuum degree: -0.095~-0.1Mpa | |
4: Temperature uniformity: ±3%℃ | |
5: Side wall temperature: ﹤35℃ | |
6: Independent large flow rate hot air circulation for 3 chambers | |
7: Power: three-phase five wire system, AC 380V | |
8: Maximum power consumption: 18KWA | |
9: Effective dimension of each chamber: H330mm×W800mm×D600mm | |
10: Net weight: 730KG | |
11: Heat-up time: About 30 minutes from room temperature ~90 ºC. Heating tube power: 5KW (each layer) | |
12: Heating method: internal heating | |
Model | |
Internal Dimension | 3×330(H)×800(W)×800(D)mm |
External Dimension | 1980(H)×1350(W)×1380(D)mm |
Principle | Adopts special purpose detector: vacuum degree (-95KPA) or Nitrogen (-18KPA), the output signal is sent to PLC which can finish: vacuum supply-nitrogen filling-vacuum supply-nitrogen filling (recycling). |
Main Parameters | 1: Independent temperature control for 3 chambers. |
2: Temperature range: room temperature~150℃ | |
3: Vacuum degree: -0.095~-0.1Mpa | |
4: Temperature uniformity: ±3%℃ | |
5: Side wall temperature: ﹤35℃ | |
6: Independent large flow rate hot air circulation for 3 chambers | |
7: Power: three-phase five wire system, AC 380V | |
8: Maximum power consumption: 18KWA | |
9: Effective dimension of each chamber: H330mm×W800mm×D600mm | |
10: Net weight: 730KG | |
11: Heat-up time: About 30 minutes from room temperature ~90 ºC. Heating tube power: 5KW (each layer) | |
12: Heating method: internal heating | |
Model | |
Internal Dimension | W800mm×D900mm×H1500mm |
External Dimension | W1250mm×D1400mm×H2275mm |
Principle | Be able to achieve: vacuum supply -nitrogen filling-heating-heat preservation-pressure maintaining and drying- vacuum supply (automatic recycling control). Be beneficial for discharging moisture and preventing oxidation. Manual control and automatic control are optional. |
Main Parameters | 1: Room temperature-150℃ |
2: Full load test, it takes less than 30 minutes from starting heating to finish baking. | |
3: Header Control Precision: ±1℃ | |
4: Temperature Uniformity: ±2℃ (full load test) | |
5: Cooling Rate: It takes less than 1 hour from 90℃ to below 40℃. | |
6: Adopts single wall and integrated pump box design, the control box is located on the right side. And blanking plate is equipped. | |
7: Vacuum Degree: ≤133Pa | |
Related products
Send Message
Other Products
Most Recent
More
Other Products
Videos