HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)

HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
HASD Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Outdoor Unit)
Request a Quote

The air cooled floor standing air conditioning unit provided by our company is a classic air conditioning equipment designed for industrial application. Of a wide range of refrigeration capacity, this industrial air cooled floor standing aircon could satisfy various requirements for refrigeration in different conditions.

It enjoying rich boundary structures and the available air flow directions of this equipment, namely the front return and front supply, front return and top supply with duct and back return and top supply with duct, make it more convenient to use. This modular aircon unit is manufactured with cold rolled metal plates which, treated by the electrostatic spray, are highly resistant to corrosion. Moreover, the hydrophilic aluminum foil cooper tube heater it is equipped with enjoys a longer mechanical lifespan.

Multiple Structures and Functions of Air Cooled Floor Standing Aircon (Compressor in Outdoor Unit)
This modular air cooled floor standing air conditioner enjoys two main subtypes-the direct blowing type and top air supply type. In order to satisfying customers' refrigeration requirements in different working conditions and occasions, we have developed rich derived types of this air conditioner, namely the single cold air type air conditioning unit, only cooling & electric heating type air conditioning unit, heat pump type air conditioning unit and steam coil type air conditioning unit. To be short, this air cooled floor standing air conditioning unit, enjoying multiple types and a wide range of refrigeration capacity, could be a nice choice for commercial and industrial application.

Front Return/Supply Type Air Cooled Floor Standing Aircon (Compressor in Outdoor Unit)
This direct blowing type air cooled air conditioning equipment adopts a two-way blow louver which enjoys further air supplying distance and large air supply volume. Of a smaller split structure and flexible operation, this air conditioning equipment is easy to install and maintain, requiring shorter project duration less investment. Therefore, this reliable air conditioner could be used in different occasions to satisfy users' refrigeration requirements.

Top Air Supply Type (Front Or Back Air Return Ducted Type) Aircon
This top air supply type air conditioner, adopting the ducted ventilation, enjoys a sound cooling performance and could be used to cool a larger space. The number of air outlets as well the installation location could be set according to the specific room environment. In order to ensure proper ventilation and moisture, we have equipped this top air supply air cooled air conditioner with air filters which helps keep the indoor air fresh and wholesome.

Lower Project Cost of Air Cooled Floor Standing Aircon
The outdoor unit of this air cooled floor standing air conditioning unit could be installed on the roof, balcony, ground, or hung on the wall. Of a laconic structure and modular design, it is quite easy to install or dismantle and users just need to connect the outdoor unit and indoor unit with cooper tubes, connecting the equipment with power supply and control line. Given this, this air conditioning unit requires lower project cost and shorter project duration.

Ultra-quite Operation of Air Cooled Floor Standing Aircon
Equipped with an advanced flexible scroll compressor and an all-side air return heat exchanger, this air cooled floor standing HVAC unit enjoys a much greater heat radiation and cooling performance. Its indoor unit is equipped with a bilateral-air-intake centrifuge which, enjoying much lower noise, is coated internally with quality moisturizing rubber. That is why the entire air conditioner could operate in an efficient, smooth and quite way.

Microcomputer Control of Air Cooled Floor Standing Aircon
This air cooled aircon unit is equipped with a microcomputer control system which enjoys such functions as the LCD display, timer switch, power off memory and real time display, quite user friendly.

Easy Inspection and Maintenance of Air Cooled Floor Standing Aircon
Of a modular design and laconic structure, this air cooled floor standing air conditioning unit is easy to install and maintain. Its indoor unit could be open from both the front and back parts or the panels. That is also true of the access panel of outdoor unit. Meanwhile, this automatic aircon unit is attached with a double-layer removable filter, easy to remove and clean.

Model of the indoor unit
Technical parameters
Project
HASD1-80H-A HASD1-120H-A HASD1-140H-A HASD1-170H-A HASD1-210H-A HASD1-250H-A HASD1-300H-A HASD1-350H-A HASD1-400H-A HASD1-450H-A HASD1-540H-A HASD1-630H-A HASD1-700H-A HASD1-800H-A HASD1-950H-A HASD1-1050H-A HASD1-1250H-A HASD1-1350H-A
Unit characteristic Cooling capacity kW 8.2 12 14.6 17.5 20.4 25 30 35.4 40 45.7 53.6 62.5 70 80 95 105 125 135
Heating capacity kW 8.6 12.6 15.3 18.4 21.4 26.3 31.5 37.2 42 48 55.8 64.6 73.5 84 100 110 130 142
E-heatingoptional(1) kW 5 6.5 8 9 11 14 15 18 22 25 30 30 35 45 50 60 65 70
E-heatingoptional(2) kW 8 10 12 14 17 22 25 30 35 40 45 50 60 / / / / /
Heat pump E-heatingOptional(3) kW 3.5 4.5 4.5 6 6 8 8 11 11 14 14 18 18 22 28 28 35 35
Input power of cooling kW 2.7 3.9 4.8 5.7 6.7 8.3 10.2 11.7 13.3 15.2 17.6 20.8 24.2 27.8 33.2 37.2 42.8 48.1
Input power of heating kW 2.75 4.05 4.9 5.8 6.9 8.5 10.4 12.3 13.9 15.9 18.5 21.4 25.2 29.1 34.8 38.8 44.5 50.2
Air flow m³/h 1550 2200 2700 3000 3500 4500 5500 6300 7200 8000 9000 10500 12500 14000 16500 18500 21000 24000
ESP Pa 0
Indoor unit noise dB(A) ≤56 ≤57 ≤58 ≤60 ≤60 ≤62 ≤62 ≤63 ≤63 ≤64 ≤64 ≤66 ≤66 ≤68 ≤68 ≤68 ≤70 ≤70
Liquid pipe size inch Φ3/8 Φ1/2 Φ1/2 Φ1/2 Φ1/2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x3 Φ5/8x3 Φ5/8x3 Φ5/8x4 Φ5/8x4
Gas pipe size inch Φ5/8 Φ3/4 Φ3/4 Φ3/4 Φ3/4 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ7/8x2 Φ1-1/8x2 Φ1-1/8x2 Φ1-3/8x2 Φ1-1/8x3 Φ1-1/8x3 Φ1-3/8x3 Φ1-1/8x4 Φ1-3/8x4
Connecting pipe direction Connecting on the left and right side
Power supply 3P~50Hz~380V
Outdoor unit number PC 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2
Outdoor unit Outdoor unit model HASIR-80NHS-B HASIR-120NHS-B HASIR-140NHS-B HASIR-170NHS-B HASIR-210NHS-B HASIR-250NHD-B HASIR-300NHD-B HASIR-350NHD-B HASIR-400NHD-B HASIR-450NHD-B HASIR-540NHD-B HASIR-630NHD-B HASIR-700NHD-B HASIR-800NHM-B HASIR-950NHM-B HASIR-1050NHD-B HASIR-630NHD-B HASIR-700NHD-B
Compressor Type rotary type Hermetic scroll type
number 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 2 2
Power supply 3P~50Hz~380V
Refrigerant Type R22
Volume Kg 3.2 4.4 5 5.6 6.3 4.4x2 5.0x2 5.6x2 6.3x2 7.2x2 8.0x2 9.5x2 10.5x2 8.0x3 9.5x3 10.5x3 9.5x2 10.5x2
Condenser Type Copper tube aluminum fin
Fin type High efficiency corrugated aluminum fin
Fan Type Low noise axial fan
Power kW 0.085 0.05x2 0.05x2 0.55 0.55 0.55 0.55 0.55 0.55x2 0.55x2 0.55x2 0.55x2 0.55x2 0.55x3 0.55x3 0.55x3 0.55x2 0.55x2
Unit dimension Width mm 960 960 960 720 720 815 815 845 1714 1880 1880 1940 1940 2900 2990 2990 1940 1940
Length mm 394 394 394 720 720 815 815 845 720 815 815 845 845 815 845 845 845 845
Height mm 800 1152 1152 1050 1050 1150 1150 1250 1130 1230 1230 1330 1330 1250 1350 1350 1330 1330
Outdoor unit noise dB(A) ≤58 ≤60 ≤60 ≤62 ≤62 ≤64 ≤64 ≤65 ≤67 ≤68 ≤70 ≤72 ≤72 ≤72 ≤73 ≤70 ≤72 ≤72
Weight kg 75 120 125 175 185 210 220 250 405 435 460 515 545 690 830 875 515 545
Indoor unit Evaporator Type Inner grooved copper tube aluminum fin
Fin type aluminum fin in Louver shape
Throttle type Expansion valve
Fan Type Low noise centrifugal fan
Drive mode Motor drive Belt-drive
Power kW 0.18 0.25 0.25 0.37 0.55 0.7 0.75 0.75 1.1 0.55x2 1.1x2 1.1x2 1.5x2 3 4 4 5.5 7.5
Electric heater type Stainless steel tube around the electric heater
Air filter Primary nylon filter
Unit dimension Width mm 590 690 690 900 900 1250 1250 1470 1470 1620 1620 1700 1700 1980 1980 1980 2200 2200
Length mm 480 520 520 520 520 550 550 600 600 650 650 800 800 1000 1000 1000 1100 1100
Height mm 1820 1870 1870 1870 1870 1870 1870 1920 1920 2050 2050 2150 1820 1870 1870 1870 1870 1870
Weight kg 75 85 87 100 110 150 160 180 185 240 245 275 285 315 325 330 355 365

Please note that
1. Cooling Condition: Outdoor temperature DB=35℃, WB=24℃; indoor temperature DB=27℃,WB=19℃;
2. Heating condition: Outdoor temperature DB=7℃, WB=6℃; Indoor temperature DB=20℃.

Indoor unit model
Technological Parameter
Project
HASD2-120H(B)-A HASD2-140H(B)-A HASD2-170H(B)-A HASD2-210H(B)-A HASD2-250H(B)-A HASD2-300H(B)-A HASD2-350H(B)-A HASD2-400H(B)-A HASD2-450H(B)-A HASD2-540H(B)-A HASD2-630H(B)-A HASD2-700H(B)-A HASD2-800H(B)-A HASD2-950H(B)-A HASD2-1050H(B)-A HASD2-1250H(B)-A HASD2-1350H(B)-A HASD2-1500H(B)-A HASD2-1700H(B)-A HASD2-1900H(B)-A HASD2-2100H(B)-A
Unit characteristic Cooling capacity kW 12 14.6 17.5 20.4 25 30 35.4 40 45.7 53.6 62.5 70 80 95 105 125 135 150 170 190 210
Heating capacity kW 12.6 15.3 18.4 21.4 26.3 31.5 37.2 42 48 55.8 64.6 73.5 84 100 110 130 142 157.5 178.5 200 220
E-heatingoptional(1) kW 6.5 8 9 11 14 15 18 22 25 30 30 35 45 50 60 65 70 / / / /
E-heatingoptional(2) kW 10 12 14 17 22 25 30 35 40 45 50 60 / / / / / / / / /
Heat pump E-heatingOptional(3) kW 4.5 4.5 6 6 8 8 11 11 14 14 18 18 22 28 28 35 35 / / / /
Input power when cooling kW 4.7 5.7 6.9 8.1 9.9 11.8 13.9 15.8 18.2 20.9 24.8 29.2 33.4 39.8 44.3 51.2 58.2 64.8 73.5 82.3 91.2
Input power when heating kW 4.9 5.9 7.2 8.4 10.3 12.3 14.8 16.9 19.6 22.2 26.1 30.7 35.1 41.9 46.5 53.8 61.3 68.3 77.5 86.8 95.6
Air flow m³/h 2200 2700 3000 3500 4500 5500 6300 7200 8000 9000 10500 12500 14000 16500 18500 21000 24000 28000 31000 34000 37000
ESP Pa 100 100 100 100 100 100 120 120 120 120 150 150 200 200 200 250 250 300 300 350 350
Indoor unit noise dB(A) ≤57 ≤58 ≤60 ≤60 ≤62 ≤62 ≤63 ≤63 ≤64 ≤64 ≤66 ≤66 ≤68 ≤68 ≤68 ≤70 ≤70 ≤72 ≤72 ≤74 ≤74
Liquid pipe size inch Φ1/2 Φ1/2 Φ1/2 Φ1/2 Φ1/2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x3 Φ5/8x3 Φ5/8x3 Φ5/8x4 Φ5/8x4 Φ5/8x5 Φ5/8x5 Φ5/8x6 Φ5/8x6
Gas pipe size inch Φ3/4 Φ3/4 Φ3/4 Φ3/4 Φ3/4 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ7/8x2 Φ1-1/8x2 Φ1-1/8x2 Φ1-3/8x2 Φ1-1/8x3 Φ1-1/8x3 Φ1-3/8x3 Φ1-1/8x4 Φ1-3/8x4 Φ1-1/8x5 Φ1-3/8x5 Φ1-1/8x6 Φ1-3/8x6
Connecting pipe direction Connecting on the left and right side
Power supply 3P~50Hz~380V
Outdoor unit number PC 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 2 2
Outdoor unit Outdoor unit model HAS1R-120NHD-B HAS1R-140NHD-B HAS1R-170NHD-B HAS1R-210NHD-B HAS1R-250NHD-B HAS1R-300NHD-B HAS1R-350NHD-B HAS1R-400NHD-B HAS1R-450NHD-B HAS1R-540NHD-B HAS1R-630NHD-B HAS1R-700NHD-B HAS1R-800NHD-B HAS1R-950NHD-B HAS1R-1050NHD-B HAS1R-630NHD-B HAS1R-700NHD-B HAS1R-630NHD-B HAS1R-950NHD-B HAS1R-700NHD-B HAS1R-1050NHD-B HAS1R-950NHM-B HAS1R-1050NHM-B
Compressor Type Hermetic scroll type
number 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 2 2 2 3 2 3 3 3
Power supply 3P~50Hz~380V
Refrigerant Type R22
Volume kg 4.4 5 5.6 6.3 4.4x2 5.0x2 5.6x2 6.3x2 7.2x2 8.0x2 9.5x2 10.5x2 8.0x3 9.5x3 10.5x3 9.5x2 10.5x2 9.5x2 9.5x3 10.5x2 10.5x3 9.5x3 10.5x3
Condenser Type Copper tube & aluminum fin
Fin type Efficient corrugated aluminum fin
Fan Type Low noise axial fan
Power kW 0.2 0.2 0.55 0.55 0.55 0.55 0.55 0.55x2 0.55x2 0.55x2 0.55x2 0.55x2 0.55x3 0.55x3 0.55x3 0.55x2 0.55x2 0.55x2 0.55x3 0.55x2 0.55x3 0.55x3 0.55x3
Unit dimension Width mm 950 950 720 720 815 815 845 1714 1880 1880 1940 1940 2900 2990 2990 1940 1940 1940 2990 1940 2990 2990 2990
Length mm 394 394 720 720 815 815 845 720 815 815 845 845 815 845 845 845 845 845 845 845 845 845 845
Height mm 1152 1152 1050 1050 1150 1150 1250 1130 1230 1230 1330 1330 1250 1350 1350 1330 1330 1330 1350 1330 1350 1350 1350
Outdoor unit noise dB(A) ≤60 ≤60 ≤62 ≤62 ≤64 ≤64 ≤65 ≤67 ≤68 ≤68 ≤72 ≤72 ≤73 ≤73 ≤73 ≤72 ≤72 ≤72 ≤73 ≤72 ≤73 ≤73 ≤73
Weight kg 120 125 175 185 210 220 250 405 435 460 515 545 690 830 875 515 545 515 830 545 875 830 875
Indoor unit Evaporator Type Inner grooved copper tube aluminum fin
Fin type aluminum fin in Louver shape
Throttle type Expansion valve
Fan Type Low noise centrifugal fan
Drive mode Belt-drive
Power kW 0.55 0.75 1.1 1.5 1.1 1.5 2.2 2.2 2.2 3 3 3 3 4 4 5.5 7.5 11 11 15 15
Electric heater type Stainless steel tube around the electric heater
Air filter Primary nylon filter
Unit dimension Width mm 690 690 900 900 1250 1250 1470 1470 1620 1620 1700 1700 1980 1980 1980 2200 2200 2510 2510 3100 3100
Length mm 520 520 520 520 550 550 600 600 650 650 800 800 1000 1000 1000 1100 1100 1300 1300 1350 1350
Height mm 1870 1870 1870 1870 1870 1870 1920 1920 2050 2050 2150 2150 1825 1975 1975 2205 2205 2305 2305 2400 2400
Weight kg 85 87 100 110 150 160 180 185 240 245 275 285 315 325 330 355 365 415 425 480 495

Please note that
1. Cooling condition: Outdoor temperature DB=35℃, WB=24℃; indoor temperature DB=27℃, WB=19℃;
2. Heating condition: Outdoor temperature DB=7℃,WB=6℃; indoor temperature DB=20℃;
3. The ESP could be set according to the users' requirement.