HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)

HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
HASN Series Air Cooled Floor Standing Air Conditioning Unit (Compressor in Indoor Unit)
Request a Quote

Product Feature of Air Cooled Floor Standing Air Conditioning Unit
1. This air cooled floor standing air conditioning unit is a reliable product designed for industrial cooling application;

2. Compared to the traditional floor standing A/C product, this air cooled floor standing aircon enjoys an outstanding design - its compressors is placed inside the indoor unit, which could 1) expand the mounting distance between the outdoor unit and indoor unit to a maximum of 60m; 2) make it easier to maintain and repair as all the core components are all installed in the inside unit. However, the disadvantage of this single-cold aircon lies in that the noise it makes is higher than that of traditional type. At the meantime, rich flow directions of the air conditioning equipment are optional now, satisfying different installation requirements of our customers: A) front return and front supply; B)front return and top supply with duct; C)back return and top supply with duct.

4. This air cooled air conditioner is equipped with cold rolled metal plates which, processed with the electrostatic spray, are highly resistant to corrosion;

5.Its heat exchanger, equipped with hydrophilic aluminum foils and cooper tubes, not only enjoys longer service lifespan but also ensures efficient heat transference;

6. Its user-friendly and considerate design enables users to choose their own way to connect the pipe with the equipment according to the specific working condition;

7. Every compressor of this industrial modular aircon is attached with a condensate tray which could effectively avoid leakage of condensate within the equipment;

8. Designed with an advanced total heat transfer technology, this industrial air conditioning equipment enjoys a much greater heat radiating performance;

9. This air cooled floor standing air conditioning unit could work in best condition throughout the year, satisfying the refrigeration needs of different industries;

10. Controlled by micro-computer, this automatic air conditioner enjoys several user-friendly functions such as the timer switch, power off memory function, real-time clock display, failure alarm, operation data record and hint function.

Types of Air Cooled Floor Standing Air Conditioning Unit
1. According to the requirements for working conditions, there are five types of this air conditioning unit, namely the single-cold pump air conditioner with an auxiliary electric heater
2. Product structure: this floor standing air conditioner mainly consists of the outdoor unit, indoor unit, electrical control box, and indoor lateral air flow conversion components.

Technological Advantages of Air Cooled Floor Standing Air Conditioning Unit
1. Designed by the senior engineers, this air cooled air conditioning unit is manufactured with quality components imported from Japan, EU and other countries and therefore has become a leading product in the domestic market;

2. Apart from its sound performance, this air cooled floor standing aircon enjoys a specially-designed outdoor unit which, of a laconic structure, costs less;

3. The split and modular design of this industrial HVAC makes it easier to dismantle and install, shortening the project duration.

Application of Air Cooled Floor Standing Air Conditioning Unit
This air cooled air conditioning unit is mainly applied in the workshops and control rooms of the machinery manufacturing, steel production, chemical industry, electronics industry and pharmaceutical industry as well as some occasions where air conditioning equipment is needed, such as restaurants, hotels, clubs and shopping malls.

Model
Technological Specifications
Project
HASD1-170N-A HASD1-210N-A HASD1-250N-A HASD1-300N-A HASD1-350N-A HASD1-400N-A HASD1-450N-A HASD1-540N-A HASD1-630N-A HASD1-700N-A HASD1-800N-A HASD1-950N-A HASD1-1050N-A HASD1-1250N-A HASD1-1350N-A
Features of the units Refrigerating capacity kW 17.5 20.4 25 30 35.4 40 45.7 53.6 62.5 70 80 95 102 125 135

cold air conditioner(stronger cold airflow and strengthened electric auxiliary heating device)(optional)
kW 14 17 22 25 30 35 40 45 50 60 / / / / /
Cooling power kW 5.7 6.7 8.3 10.2 11.7 13.3 15.2 17.6 20.8 24.2 27.8 33.2 37.2 42.8 48.1
Circulating air volume m³/h 3000 3500 4500 5500 6300 7200 8000 9000 10500 12500 14000 16500 18500 21000 24000
External static pressure Pa 0
Noise of indoor unit dB(A) ≤60 ≤60 ≤62 ≤62 ≤63 ≤63 ≤64 ≤64 ≤66 ≤66 ≤68 ≤68 ≤68 ≤70 ≤70
Connecting pipe for the liquid line inch Φ1/2 Φ1/2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x3 Φ5/8x3 Φ5/8x3 Φ5/8x4 Φ5/8x4
Connecting pipe for the exhaust pipe inch Φ1/2 Φ1/2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ3/4x3 Φ3/4x3 Φ3/4x3 Φ3/4x4 Φ3/4x4
Pipe connection method with the equipment faced to the front part, its left side and right side are connected with pipes
Power supply 3P~50H~380V
Number of outdoor unit Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2
Outdoor unit Model of the outdoor unit HAS1R-170S-B HAS1R-210S-B HAS1R-250D-B HAS1R-300D-B HAS1R-350D-B HAS1R-400D-B HAS1R-450D-B HAS1R-540D-B HAS1R-630D-B HAS1R-700D-B HAS1R-800M-B HAS1R-950M-B HAS1R-1050M-B HAS1R-630D-B HAS1R-700D-B
Condenser Model type Fins &cooper tube
Form of the fin Efficient corrugated aluminum fin
Condenser fan Type Low noise axial fan
Power kW 0.55 0.55 0.55 0.55 0.55 0.55x2 0.55x2 0.55x2 0.55x2 0.55x2 0.55x3 0.55x3 0.55x3 0.55x3 0.55x3
Boundary dimensions Width mm 720 720 815 815 845 1714 1880 1880 1940 1940 2900 2990 2990 1940 1940
Depth mm 720 720 815 815 845 720 815 815 845 845 815 845 845 845 845
Height mm 1050 1050 1150 1150 1250 1130 1230 1230 1330 1330 1250 1350 1350 1330 1330
Noise of the outdoor unit dB(A) ≤62 ≤62 ≤64 ≤64 ≤65 ≤67 ≤68 ≤70 ≤70 ≤72 ≤73 ≤73 ≤73 ≤72 ≤73
Weight kg 80 85 115 120 125 225 275 280 290 295 450 460 465 290 295
Indoor unit Compressor Type Hermetic scroll compressor
Number 1 1 2 2 2 2 2 2 2 2 3 3 3 4 4
Power supply 3P~50H~380V
Refrigerant Type R22
Charge amount kg 5.6 6.3 4.4x2 5.0x2 5.6x2 6.3x2 7.2x2 8.0x2 9.5x2 10.5x2 8.0x3 9.5x3 10.5x3 9.5x4 10.5x4
Evaporator Type Fins& inner grooved cooper tube
Form of the fin Aluminum louvered fin coated with hydrophilic film
Throttle mode External balanced thermal expansion valve
Draught fan Type Low noise centrifugal fan
Drive mode Direct drive by motor Belt drive
Power kW 0.37 0.55 0.7 0.75 0.75 1.1 0.55x2 1.1x2 1.1x2 1.5x2 3 4 4 5.5 7.5
Electric heater type Stainless steel spiral fin tube
Air filter Nylon mesh primary air filter
Boundary dimensions Width mm 900 900 1250 1250 1470 1470 1620 1620 1700 1700 1980 1980 1980 2200 2200
Depth mm 520 520 550 550 600 600 650 650 800 800 1000 1000 1000 1100 1100
Height mm 1870 1870 1870 1870 1920 1920 2050 2050 2150 2150 2210 2360 2360 2600 2600
Weight kg 195 210 260 275 315 380 420 435 485 540 620 645 735 780 880

Please note that
1. Cooling Condition: outdoor temperature: DB=35℃, WB=24℃; indoor temperature: DB=27℃, WB=19℃;
2. There is no heat pumping system inside this air cooled floor standing air conditioning unit(compressor in indoor unit)

Indoor unit model type
Technological specifications
Project
HASD2-170N(B)-A HASD2-210N(B)-A HASD2-250N(B)-A HASD2-300N(B)-A HASD2-350N(B)-A HASD2-400N(B)-A HASD2-450N(B)-A HASD2-540N(B)-A HASD2-630N(B)-A HASD2-700N(B)-A HASD2-800N(B)-A HASD2-950N(B)-A HASD2-1050N(B)-A HASD2-1250N(B)-A HASD2-1350N(B)-A HASD2-1500N(B)-A HASD2-1700N(B)-A HASD2-1900N(B)-A HASD2-2100N(B)-A
Features of the units Refrigerating capacity kW 17.5 20.4 25 30 35.4 40 45.7 53.6 62.5 70 80 95 105 125 135 150 170 190 210
Heat pump E-heatingOptional kW 9 11 14 15 18 22 25 30 30 35 45 50 60 65 70 / / / /
cold air conditioner(stronger cold airflow and strengthened electric auxiliary heating device)(optional) kW 14 17 22 25 30 35 40 45 50 60 / / / / / / / / /
Refrigerating power kW 6.9 8.1 9.9 11.8 13.9 15.8 18.2 20.9 24.8 29.2 33.4 39.8 44.3 51.2 58.2 64.8 73.5 82.3 91.2
Circulating air volume m³/h 3000 3500 4500 5500 6300 7200 8000 9000 10500 12500 14000 16500 18500 21000 24000 28000 31000 34000 37000
External static pressure Pa 100 100 100 100 120 120 120 120 150 150 200 200 200 250 250 300 300 350 350
Noise of the indoor unit dB(A) ≤60 ≤60 ≤62 ≤62 ≤63 ≤63 ≤64 ≤64 ≤66 ≤66 ≤68 ≤68 ≤68 ≤70 ≤70 ≤72 ≤72 ≤74 ≤74
Connecting pipe for the liquid line inch Φ1/2 Φ1/2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x2 Φ5/8x3 Φ5/8x3 Φ5/8x3 Φ5/8x4 Φ5/8x4 Φ5/8x5 Φ5/8x5 Φ5/8x6 Φ5/8x6
Connecting pipe for the exhaust pipe inch Φ1/2 Φ1/2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ1/2x2 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ3/4x2 Φ3/4x3 Φ3/4x3 Φ3/4x3 Φ3/4x4 Φ3/4x4 Φ3/4x5 Φ3/4x5 Φ3/4x6 Φ3/4x6
Pipe connecting method With the equipment faced to the front part, the pipes are connected with its right side and left side
Power supply 3P~50Hz~380V
Number of outdoor unit Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1
Outdoor unit Model of outdoor unit HAS1R-170S-B HAS1R-210S-B HAS1R-250D-B HAS1R-300D-B HAS1R-350D-B HAS1R-400D-B HAS1R-450D-B HAS1R-540D-B HAS1R-630D-B HAS1R-700D-B HAS1R-800M-B HAS1R-950M-B HAS1R-1050M-B HAS1R-630D-B HAS1R-700D-B HAS1R-630D-B HAS1R-950M-B HAS1R-700D-B HAS1R-1050M-B HAS1R-950M-B HAS1R-1050M-B
Condenser Type Fins& cooper tube
Form of fin Efficient corrugated aluminum fins
Condenser fan Type Low noise axial fan
Power kW 0.55 0.55 0.55 0.55 0.55 0.55x2 0.55x2 0.55x2 0.55x2 0.55x2 0.55x3 0.55x3 0.55x3 0.55x2 0.55x2 0.55x2 0.55x3 0.55x2 0.55x3 0.55x3 0.55x3
Boundary dimensions Width mm 720 720 815 815 845 1714 1880 1880 1940 1940 2900 2990 2990 1940 1940 1940 2990 1940 2990 2990 2990
Depth mm 720 720 815 815 845 720 815 815 845 845 815 845 845 845 845 845 845 845 845 845 845
Height mm 1050 1050 1150 1150 1250 1130 1230 1230 1330 1330 1250 1350 1350 1330 1330 1330 1350 1330 1350 1350 1350
Noise of the outdoor unit dB(A) ≤62 ≤62 ≤64 ≤64 ≤65 ≤67 ≤68 ≤70 ≤72 ≤72 ≤72 ≤73 ≤73 ≤72 ≤72 ≤72 ≤73 ≤72 ≤73 ≤73 ≤73
Weight kg 80 85 115 120 125 225 275 280 290 295 450 460 465 290 295 290 460 295 465 460 465
Indoor unit Compressor Type Hermetic scroll compressor
Number 1 1 2 2 2 2 2 2 2 2 3 3 3 4 4 5 5 6 6
Power supply 3P~50Hz~380V
Refrigerant Type R22
Charge amount kg 5.6 6.3 4.4x2 5.0x2 5.6x2 6.3x2 7.2x2 8.0x2 9.5x2 10.5x2 8.0x3 9.5x3 10.5x3 9.5x4 10.5x4 9.5x5 10.5x5 9.5x6 10.5x6
Evaporator Type Fins& inner grooved cooper tube
Form of the fin Aluminum louvered fin coated with hydrophilic film
Throttle mode External balanced thermal expansion valve
Fraught fan Type Low noise centrifugal fan
Drive mode Belt drive
Power kW 1.1 1.5 1.1 1.5 2.2 2.2 2.2 3 3 3 3 4 4 5.5 7.5 11 11 15 15
Electrical heater type Stainless steel spiral fin tube
Air filter Nylon mesh primary air filter
Boundary dimensions Width mm 900 900 1250 1250 1470 1470 1620 1620 1700 1700 1980 1980 1980 2200 2200 2510 2510 3100 3100
Depth mm 520 520 550 550 600 600 650 650 800 800 1000 1000 1000 1100 1100 1300 1300 1350 1350
Height mm 1870 1870 1870 1870 1920 1920 2050 2050 2150 2150 1825 1975 1975 2205 2205 2305 2305 2400 2400
Weight kg 235 245 275 290 310 350 450 500 650 700 820 920 1000 1150 1250 1380 1450 1650 1650

Please note that
1. cooling condition: outdoor temperature: DB=35℃, WB=24℃; indoor temperature: DB=27℃, WB=19℃;
2. heating condition: outdoor temperature: DB=7℃, WB=6℃; indoor temperature: DB=20℃ ;
3. The external static pressure of this air conditioning equipment could be set according to your specific needs.