HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)

HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
HSLFL Series Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)
Request a Quote

Features of Water Cooled Packaged Air Conditioning Unit
1. This water cooled packaged air conditioning unit, of multiple available flow directions, could satisfy customers' different requirements. Now the following are quite welcomed by customers:

A)front return and front supply; B)front return and top supply with duct; C)back return; D)top supply with duct.

2. This water cooled air conditioner is equipment with cold rolled metal panels which, treated by electrostatic spray, are highly resistant to corrosion;

3. Its highly efficient heat transfer system enables the unit to enjoy a more laconic structure, smaller volume and a much higher EER of 3.7;

4. Sound noise control device of this air conditioner ensures this industrial packaged aircon to operate with lower noise;

5. The compressor and control box of this water cooled HVAC, installed on the in the indoor unit, is easy to inspect and maintain;

6. Additional condensate plate for each compressor could ensure no condensate leakage;

7. The primary air filter attached to the industrial aircon is easy to dismantle and clean.

Functions of Water Cooled Packaged Air Conditioning Unit
1. Mechanical industry: this industrial water cooled packaged aircon could be used to control the oil temperature of hydraulic system and ensure precise hydraulic pressures, helping your equipment operate in a smooth, secure and efficient way and expanding its service lifespan;

2. Electroplating industry: this cabinet air conditioner could effectively control the bath temperature, promoting product quality;

3. Plastic industry: water cooled packaged air conditioning unit could ensure precise mold temperature in the plastic production and improve product quality;

4. Vacuum equipment manufacturing industry: this horizontal type air conditioning machine could accurately control the furnace temperature and promote production efficiency, ensuring good quality of the products;

5. Electronic industry: this water cooled packaged air cooling unit could help the electronic units on the production line keep stable molecular structure and protect them;

6. Food industry: this automatic air conditioner is a necessary equipment for food storage in that it could keep stable storage temperature.

Front Return/Supply Type Water Cooled Packaged Air Conditioning Unit (Scroll Compressor) (10÷160kW)

Front Return/Top Supply with Duct Type Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)(58÷240KW)

Back Return/Top Supply with Duct Type Water Cooled Packaged Air Conditioning Unit (Scroll Compressor)(58÷240KW)

Indoor unit model
Parameter
Project
HSLF1-10D HSLF1-14D HSLF1-17D HSLF1-20D HSLF1-25D HSLF1-30D HSLF1-35D HSLF1-40D HSLF1-45D HSLF1-55D HSLF1-60D HSLF1-70D HSLF1-80D HSLF1-95D HSLF1-105D HSLF1-120D HSLF1-135D HSLF1-150D
Unit characteristic Cooling capacity kW 10 14 17 20 25 30 35 40 45 55 60 70 80 95 105 120 135 150
E-heating optional kW 5 8 10 11 14 15 18 22 25 30 35 35 45 50 60 65 70 80
Input power kW 2.72 3.8 4.6 5.5 6.8 8.2 9.5 10.9 12.2 14.9 16.4 19.2 22 26.5 30 33.6 38.5 42
Air flow m3/h 1550 2200 2500 3000 3800 4500 5500 6300 7200 8200 9200 11000 12500 14500 17500 19000 22000 24500
ESP Pa 0
Refrigerant R22
Cooling water pipe size inch G1" G1-1/2" G2" G2-1/2"
Power supply 3P~50Hz~380V/1P~50Hz~220V
Noise dB(A) ≤58 ≤58 ≤58 ≤60 ≤60 ≤62 ≤62 ≤63 ≤63 ≤64 ≤64 ≤66 ≤66 ≤68 ≤68 ≤68 ≤70 ≤70
Unit dimension Width mm 590 690 690 900 900 1250 1250 1470 1470 1620 1620 1700 1700 1980 1980 1980 2200 2200
Length mm 480 520 520 520 520 550 550 600 600 650 650 800 800 820 920 1000 1150 1250
Height mm 1820 1870 1870 1870 1870 1870 1870 1920 1920 2050 2050 2150 2150 2210 2360 2360 2600 2600
Weight kg 142 185 205 235 245 275 290 320 340 425 450 515 535 820 920 100 1150 1250
Compressor Type Hermetic rotary type Hermetic scroll type
Number 1 2 3 4
Power supply 3P~50Hz~380V
Refrigerant Volume kg 1.9 2.7 3.3 3.8 4.4 2.7x2 3.3x2 3.8x2 4.4x2 5.0x2 6.1x2 6.6x2 7.7x2 6.0x3 7.0x3 7.7x3 6.6x4 7.5x4
Condenser Type High efficiency flooded tank Shell and tube
Water flow m3/h 2.3 3.3 3.9 4.6 5.8 6.9 8 9.2 10.4 11.5 13.8 16 18.4 21.8 24.1 27.5 30.9 34.4
Water resistance kPa 12 16 18 26 28 24 24 30 30 34 34 36 38 40 42 42 44 44
Evaporator Type Copper tube aluminum fin
Fin type aluminum fin in Louver shape
Throttle type expansion valve
Supply fan Type Low noise centrifugal fan
Drive mode Motor drive
Power kW 0.18 0.25 0.25 0.37 0.55 0.7 0.75 0.75 1.1 0.55x2 1.1x2 1.1x2 1.5x2 3 4 4 5.5 7.5
Electric heater type Stainless steel tube around the electric heater
Air filter Primary nylon filter
Drain pipe size inch G3/4" G1"

Please note that
1. Cooling condition: return air temperature: DB=27 ℃; WB=19 ℃; inlet water temperature 30 ℃; outlet water temperature 35 ℃;
2. The above cooling input power datum doesn't take into account that of the cooling tower motor and the water pump input power;
3. No further notice will be given when the above parameter is modified;
4. The above refrigerant volume is only true of the R22.

Indoor unit model
Parameter
Project
HSLF-14D(B) HSLF-17D(B) HSLF-20D(B) HSLF-25D(B) HSLF-30D(B) HSLF-35D(B) HSLF-40D(B) HSLF-45D(B) HSLF-55D(B) HSLF-60D(B) HSLF-70D(B) HSLF-80D(B) HSLF-95D(B) HSLF-105D(B) HSLF-120D(B) HSLF-135D(B) HSLF-150D(B) HSLF-170D(B) HSLF-190D(B) HSLF-210D(B) HSLF-230D(B)
Unit characteristic Cooling capacity kW 14 17 20 25 30 35 40 45 55 60 70 80 95 105 120 135 150 170 190 210 230
E-heating optional kW 8 10 11 14 15 18 22 25 30 35 35 45 50 60 65 70 80 / / / /
Input power kW 4.3 5.2 6.1 7.7 9.3 10.9 12.3 13.9 16.9 18.6 21.9 25.1 29.8 33.2 37.9 43.3 48.8 55.7 62.6 69.3 77.4
Air flow m3/h 2500 3000 3500 4000 5000 6000 6600 7500 8500 9500 11500 13000 15000 17500 19500 23000 25000 28000 31000 34000 37000
ESP Pa 100 100 100 100 100 100 120 120 120 120 150 150 200 200 200 250 250 300 300 350 350
Refrigerant R22
Cooling water pipe size inch G1" G1-1/2" G2" G2-1/2"
Power supply 3P~50Hz~380V/1P~50Hz~220V
Noise dB(A) ≤60 ≤60 ≤60 ≤60 ≤62 ≤62 ≤64 ≤64 ≤66 ≤66 ≤68 ≤68 ≤70 ≤70 ≤70 ≤72 ≤72 ≤74 ≤74 ≤76 ≤76
Unit dimension Width mm 690 690 900 900 1250 1250 1470 1470 1620 1620 1700 1700 1980 1980 1980 2200 2200 2510 2510 3100 3100
Length mm 520 520 520 520 550 550 600 600 650 650 800 800 1000 1000 1000 1100 1100 1300 1300 1350 1350
Height mm 1870 1870 1870 1870 1870 1870 1920 1920 2050 2050 2150 2150 1825 1975 1975 2200 2200 2300 2300 2400 2400
Weight kg 190 210 240 250 280 295 325 345 430 455 520 540 590 625 635 690 715 765 785 835 850
Compressor Type Hermetic scroll type
Q'ty 1 2 3 4 5 6
Power supply 3P~50Hz~380V
Refrigerant Volume Kg 2.7 3.3 3.8 3.8 2.7x2 3.3x2 3.8x2 4.4x2 5.0x2 6.1x2 6.6x2 7.7x2 6.0x3 7.0x3 7.7x3 6.6x4 7.5x4 6.6x5 7.5x5 7.0x6 7.7x6
Condenser Type High efficiency flooded tank Shell and tube
Water flow m3/h 3.3 3.9 4.6 5.8 6.9 8 9.2 10.4 11.5 13.8 16 18.4 21.8 24.1 27.5 30.9 34.4 39 43.6 48.2 52.8
Water resistance kPa 16 18 26 28 24 24 30 30 34 34 36 38 40 42 42 44 44 46 46 48 48
Evaporator Type Copper tube aluminum fin
Fin type aluminum fin in Louver shape
Throttle type Expansion valve
Fan Type Low noise centrifugal fan
Drive mode Belt-drive
Power kW 0.55 0.75 1.1 1.5 1.1 1.5 2.2 2.2 2.2 3 3 3 3 4 4 5.5 7.5 11 11 15 15
Electric heater type Stainless steel tube around the electric heater
Air filter Primary nylon filter
drain pipe size inch G3/4" G1" G1-1/4"

Please note that
1. Cooling condition: return air temperature: DB=27℃; WB=19℃; inlet water temperature 30℃; outlet water temperature 35℃;
2. The above cooling input power datum doesn't take into account that of the cooling tower motor and the water pump input power;
3. No further notice will be given when the above parameter is modified;
4. The above refrigerant volume is only true of the R22.