Ammonia Liquid Receiver
Ammonia Liquid Receiver
1. Product Description
Our ammonia liquid receiver is used in refrigerating system to adjust andstabilize circulating load of ammonia liquid. It can also be used to storeammonia liquid.
2. Design Pressure and Test Pressure
Design pressure: 2Mpa
Water pressure test: 2.5Mpa
Air-tight test: 2Mpa
Note: The ammonia liquid receiver isavailable in two types: A type has connecting pipes for safety valve, while B typedoesn’t have such pipes.
3. Technical Parameters of AmmoniaLiquid Receiver
Type | Model | Volume (L) | Type of vessel | Size of cylinder body (mm) | Pipe-connecting size (mm) | | Support size (mm) | Weight (kg) | |||||||||||||||||||
L1 | D | d1 | d2 | d3 | H | H1 | H2 | L | L2 | L3 | L4 | L5 | L6 | L7 | L8 | L9 | L10 | B | B1 | D1 | a | b | |||||
A type | ZA | 0.245 | ⅡMC | 2000 | ¢412 | 25 | 25 | 15 | 750 | 230 | 600 | 2462 | 132 | 210 | 150 | 400 | 400 | 300 | 400 | 1000 | 100 | 360 | 280 | 18 | 145 | 120 | 230 |
ZA | 0.512 | ⅡMC | 1600 | ¢616 | 25 | 25 | 15 | 930 | 310 | 800 | 2203 | 203 | 280 | 220 | 300 | 250 | 250 | 250 | 800 | 200 | 455 | 375 | 23 | 145 | 120 | 300 | |
ZA | 0.942 | ⅡMC | 3200 | ¢616 | 32 | 25 | 15 | 944 | 310 | 800 | 3803 | 203 | 280 | 220 | 400 | 1100 | 500 | 400 | 1800 | 200 | 455 | 375 | 23 | 145 | 120 | 440 | |
ZA | 1.632 | ⅡMC | 3000 | ¢820 | 40 | 32 | 20 | 260 | 512 | 1000 | 3733 | 253 | 360 | 300 | 400 | 1000 | 500 | 400 | 1400 | 200 | 640 | 560 | 23 | 145 | 120 | 685 | |
ZA | 2.114 | ⅡMC | 4000 | ¢820 | 50 | 40 | 20 | 1294 | 512 | 1000 | 4733 | 253 | 380 | 300 | 400 | 1600 | 600 | 400 | 2400 |