Glass-Lined Reactor, K Type
Request a Quote
Technical Parameters of the Glass-Lined Reactor
K50L-K500L Glass-Lined Reactor
K50L-K500L Glass-Lined Reactor
- K50L-K100L Design Drawing (Plan View)
- K200L-K500L Design Drawing (Plan View)
| Internal Vessel | Jacket | |
| Design Pressure ( MPa ) | 0.4 | 0.6 |
| Design Temperature ( ℃ ) | -19~200 | -19~200 |
| Symbol | Usage |
| a | Manhole |
| b | Agitator Hole |
| c | Thermowell |
| d | Medium Outlet |
| e1,e2 | Sightglass |
| f,g | Spare |
| k1,k2,k3,k4 | In/Outlet |
| m | Vent Hole |
| Specifications (Unit:mm) | ||||||
| Model | ||||||
| Nominal Capacity (L) | 50 | 100 | 200 | 300 | 500 | |
| Total Capacity (L) | 104 | 180 | 338 | 483 | 743 | |
| Calculated Capacity (Notes 1) (L) | 71 | 128 | 247 | 369 | 588 | |
| Jacket Capacity (L) | 21 | 32 | 57 | 92 | 130 | |
| Heat Exchange Area (m2) | 0.53 | 0.85 | 1.26 | 1.75 | 2.64 | |
| Reference Weight (kg) | 310 | 380 | 595 | 795 | 985 | |
| Dimensions | d1 | 500 | 600 | 700 | 800 | 900 |
| d2 | 600 | 700 | 800 | 900 | 1000 | |
| d3(Notes 2) | 872 | 987 | 1087 | 1188 | 1288 | |
| d4 | 420 | 520 | 620 | 720 | 810 | |
| d5 | 300 | 300 | 400 | 500 | 500 | |
| h1 | 400 | 500 | 700 | 800 | 1000 | |
| h2 | 280 | 310 | 355 | 390 | 415 | |
| h3 | 220 | 250 | 270 | 280 | 280 | |
| h4 | 300 | 340 | 370 | 390 | 400 | |
| h | 1800 | 1920 | 2450 | 2725 | 2955 | |
| B | 250 | 250 | 250 | 250 | 270 | |
| Φ | 24 | 24 | 24 | 24 | 24 | |
| Vessel Nozzle DN | a | 80 | 80 | 125 | 125 | 150 |
| b | 65 | 65 | 100 | 100 | 100 | |
| c | 65 | 65 | 65 | 65 | 65 | |
| d | 65 | 65 | 80 | 80 | 80 | |
| e1 | 65 | 65 | 65 | 65 | 80 | |
| e2 | / | / | 65 | 65 | 80 | |
| f | 65 | 65 | 80 | 80 | 100 | |
| g | / | / | 65 | 65 | 125 | |
| Jacket Nozzle DN | k1 | 20 | 20 | 25 | 25 | 32 |
| k2 | 20 | 20 | 25 | 25 | 32 | |
| k3 | 20 | 20 | 25 | 25 | 32 | |
| K4 | 20 | 20 | 25 | 25 | 32 | |
| m | G3/8'' | G3/8'' | G3/8'' | G3/8'' | G3/8'' | |
| Drive | DN | 40 | 40 | 50 | 65 | 65 |
| h5 | 980 | 980 | 1250 | 1400 | 1400 | |
| Notes 1: Calculated Capacity:Volume under highneck flange. Notes 2: Support types could be determined by users;Without special request,lugs would be normally applied. | ||||||
K1000L-K6300L Glass-Lined Reactor
K1000L-K6300L Glass-Lined Reactor
K1000L-K6300L Design Drawing (Plan View)
| Internal Vessel | Jacket | |
| Design Pressure (MPa) | 0.4 | 0.6 |
| Design Temperature ( ℃ ) | -19~200 | -19~200 |
| Specifications (Unit:mm) | ||||||||
| Model | ||||||||
| Nominal Capacity (L) | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6300 | |
| Total Capacity (L) | 1616 | 2172 | 2640 | 4170 | 5140 | 6470 | 7580 | |
| Calculated Capacity (Note 1) (L) | 1244 | 1714 | 2180 | 3370 | 4334 | 5443 | 6561 | |
| Jacket Capacity (L) | 206 | 340 | 434 | 520 | 670 | 873 | 1027 | |
| Heat Exchange Area (m²) | 4.55 | 5.76 | 7.23 | 9.33 | 11.85 | 13.74 | 16.43 | |
| Half-Pipe Coil Heat Exchange Area (m²) | 1.8 | 2.8 | 3.6 | 4.0 | 5.3 | 7.0 | 8.4 | |
| Reference Weight (kg) | 1700 | 2155 | 2415 | 3500 | 4055 | 4840 | 5490 | |
| Dimensions (mm) | d1 | 1200 | 1300 | 1300 | 1600 | 1600 | 1750 | 1750 |
| d2 | 1300 | 1450 | 1450 | 1750 | 1750 | 1900 | 1900 | |
| d3 (Note 2) | 1638 | 1915 | 1915 | 2221 | 2221 | 2412 | 2412 | |
| d4 | 1080 | 1180 | 1180 | 1440 | 1440 | 1580 | 1580 | |
| d5 | 700 | 700 | 700 | 800 | 800 | 850 | 850 | |
| h1 | 1200 | 1400 | 1830 | 1810 | 2290 | 2410 | 2875 | |
| h2 | 495 | 520 | 520 | 605 | 605 | 642.5 | 642.5 | |
| h3 | 290 | 330 | 330 | 340 | 340 | 340 | 340 | |
| h4 | 600 | 650 | 650 | 700 | 700 | 700 | 700 | |
| h | 3445 | 3660 | 4010 | 4280 | 4745 | 4900 | 5470 | |
| B1 | 315 | 315 | 315 | 315 | 315 | 350 | 350 | |
| B2 | 350 | 400 | 400 | 450 | 450 | 500 | 500 | |
| Φ | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| Vessel Nozzle DN (mm) | a | 300x400 | 300x400 | 300x400 | 300x400 | 300x400 | 300x400 | 300x400 |
| b | 125 | 125 | 125 | 150 | 150 | 150 | 150 | |
| C | 100 | 100 | 100 | 100 | 100 | 125 | 125 | |
| d | 100 | 100 | 100 | 100 | 100 | 125 | 125 | |
| e | 100 | 125 | 125 | 125 | 125 | 125 | 125 | |
| f | 125 | 125 | 125 | 125 | 125 | 150 | 150 | |
| g | 100 | 100 | 100 | 100 | 100 | 125 | 125 | |
| h | 100 | 125 | 125 | 125 | 125 | 150 | 150 | |
| 100 | 100 | 100 | 125 | 125 | 125 | 125 | ||
| Jacket Nozzle DN (Note 3) (mm) | k1 | 32/32 | 40/50 | 40/50 | 50/50 | 50/50 | 65/50 | 65/50 |
| k2 | 32 | 40 | 40 | 50 | 50 | 65 | 65 | |
| k3 | 32/32 | 40/50 | 40/50 | 50/50 | 50/50 | 65/50 | 65/50 | |
| k4 | 32 | 40 | 40 | 50 | 50 | 65 | 65 | |
| m | G3/8” | G3/8" | G3/8” | G3/8” | G3/8” | G3/8” | G3/8” | |
| Drive (Note 4) (mm) | dN | 80 | 80 | 80 | 95 | 95 | 95 | 95 |
| h5 | 1580 | 1580 | 1580 | 1680 | 1680 | 1680 | 1780 | |
Notes
- Calculated Capacity
Volume: Measures the capacity below the high neck flange. This does not include the volume taken up by the flange itself. - Support Options
The type of support used to hold the reactor can be specified by the customer when placing an order. If no preference is indicated, the default support type will be lugs attached to the exterior. - k1 and k3 Values
The dimensions k1 and k3 will vary depending on whether the reactor has a full jacket or half pipe heating/cooling system.
For a full jacket, use the values listed before the slash (/)
For half pipes, use the values after the slash (/) - Drive Device Parameters
Reference Only: The provided drive device parameters are for reference purposes.
Actual Selection: The final selection of the rack reducer type will be determined based on the specific requirements of the application.
K8000L-K16000L Glass-Lined Reactor
K8000L-K16000L Glass-Lined Reactor
- K8000L Design Drawing (Plan View)
- K10000L-K16000L Design Drawing (Plan View)
| Internal Vessel | Jacket | |
| Design Pressure ( MPa ) | 0.2 | 0.6 |
| Design Temperature ( ℃ ) | -19~200 | -19~200 |
| Specifications (Unit:mm) | |||||
| Model | |||||
| Nominal Capacity (L) | 8000 | 10000 | 12500 | 16000 | |
| Total Capacity (L) | 10380 | 12870 | 15380 | 18500 | |
| Calculated Capacity (Note 1) (L) | 8897 | 10930 | 13440 | 16000 | |
| Jacket Capacity (L) | 1724 | 1940 | 2324 | 2500 | |
| Heat Exchange Area (m²) | 19.6 | 21.54 | 26.5 | 28.0 | |
| Half-Pipe Coil Heat Exchange Area (m²) | 9.4 | 10.5 | 12.4 | 14.5 | |
| Reference Weight (kg) | 7560 | 8380 | 9950 | 12550 | |
| Dimensions (mm) | d1 | 2000 | 2200 | 2200 | 2400 |
| d2 | 2200 | 2400 | 2400 | 2600 | |
| d3 (Note 2) | 2763 | 2964 | 2964 | 3238 | |
| h1 | 3000 | 3060 | 3720 | 3740 | |
| h2 | 710 | 770 | 770 | 825 | |
| h3 | 380 | 400 | 400 | 460 | |
| h4 | 830 | 850 | 850 | 900 | |
| h | 5930 | 6010 | 6690 | 6850 | |
| B1 | 400 | 470 | 470 | 470 | |
| B2 | 700 | 700 | 700 | 700 | |
| Φ | 36 | 36 | 36 | 36 | |
| Vessel Nozzle DN (mm) | a | 125 | 150 | 150 | 150 |
| C | 300x400 | 300x400 | 300x400 | 450 | |
| d | 200 | 200 | 200 | 200 | |
| e1 | 200 | 200 | 200 | 200 | |
| e2 | 150 | 200 | 200 | 200 | |
| g1 | 150 | 150 | 150 | 150 | |
| g2 | 150 | 150 | 150 | 150 | |
| g3 | 150 | 150 | 150 | 150 | |
| g4 | / | 150 | 150 | 150 | |
| S | 125 | 125 | 125 | 125 | |
| k | 125 | 125 | 125 | 125 | |
| Jacket Nozzle DN (Note 3) (mm) | b1 | 65/65 | 80/65 | 80/65 | 100/65 |
| b2 | 65 | 80 | 80 | 100 | |
| b3 | 65/65 | 80/65 | 80/65 | 100/65 | |
| b4 | 65 | 80 | 80 | 100 | |
| m | G3/4” | G3/4” | G3/4” | G3/4” | |
| n | G1/2” | G1/2” | G1/2” | G1/2” | |
| Drive (Note 4) (mm) | dN | 110 | 110 | 110 | 110 |
| h5 | 2000 | 2000 | 2020 | 2090 | |
Notes
- Calculated Capacity
Volume: Measures the capacity below the high neck flange. This does not include the volume taken up by the flange itself. - Support Options
The type of support used to hold the reactor can be specified by the customer when placing an order. If no preference is indicated, the default support type will be lugs attached to the exterior. - b1 and b3 Values
The dimensions b1 and b3 will vary depending on whether the reactor has a full jacket or half pipe heating/cooling system.
For a full jacket, use the values listed before the slash (/)
For half pipes, use the values after the slash (/)
- Drive Device Parameters
Reference Only: The provided drive device parameters are for reference purposes.
Actual Selection: The final selection of the rack reducer type will be determined based on the specific requirements of the application.
Related Manufacturies
Leave Message
Similar Manufacturies and Parts
Manufacturer Advertising
Similar Manufacturies and Parts
Videos