FKH Cooling Tower with Sidestream Filtration

FKH Cooling Tower with Sidestream Filtration
FKH Cooling Tower with Sidestream Filtration
Request a Quote

Main Characteristics of FKH Open Circuit Cooling Tower
Single-Side Air Inlet
Provide Direct-Coupled or Belt-Driven Fan to Choose from

High Efficiency of FKH Cooling Tower with Sidestream Filtration
The FKH cooling tower with side-stream filtration WANXIANG provides to you is a highly efficient industrial cooling apparatus that could be equipped with PVC cooling fins of higher cooling capacity. Its cooling fillers could keep sound hydrophilia for a much longer time, effectively reducing the linear pressure loss and enjoying a greater cooling performance. Its derived types, both including the dry cooling tower and wet cooling tower, could also enjoy excellent cooling performances.

Easy Maintenance of FKH Cooling Tower with Sidestream Filtration
This large size open cooling equipment enjoys a larger internal space which could allow the operator or inspector to come into the tower, making it easier to adjust and replace motor, belts, water spray system and other components. Meanwhile, the steel parts which fix the PVC cooling fillers are removable, bringing convenience to replacement of the fillers.

Application of FKH Cooling Tower with Sidestream Filtration
The cooling tower with sidestream filtration provided by Wanxiang is quite suitable to be used in a working place where, of a higher temperature (60-35 ºC) or a larger temperature difference from 5 ºC to 25 ºC, a large cooling capacity is required. Now anther two derived types of it, namely the round cooling tower and square cooling tower become more appealing to customers.
1. Temperature of liquids to be cooled: 40-90℃
2. Maximum temperature difference: 25℃, Optimum temperature difference: 6-15℃
3. Suitable wet bulb temperature for projects: ≥10℃
4. Average noise value: dB65-76
5. Suitable cooling rate for projects: more than 30L/s
6. Cooling capacity of single module: 270KW-6,300KW
7. FKH cooling tower is ideal for projects which have requirements for high water temperature of industrial process. Due to single-side air inlet, it will not affect the thermal performance of equipment when applied in those places bordered on three sides by the barrier. This product can be also used in civil air conditioning projects and energy-storage tower projects.

Technical Specifications of FKH Cooling Tower with Sidestream Filtration

The FKH Single Box Cooling Tower with Sidestream Filtration
Model Flow 98.6-89.6°C
(GPM)
Fan Inlet (In) Outlet ( In ) Shipping Weight
(lbs)
Operating Weight
(lbs)
Dimensions Basic Dimensions

Power
(HP)
Airflow Rate
(CFM)
L
(mm)
W
(mm)
h1
(mm)
h2
(mm)
H
(mm)
A
(mm)
B
(mm)

FKH-711P 165 3 18588 4" 4" 1870 4180 1850 2250 2692 / 3112 2100 2500
FKH-711G 205 4 23294 4" 4" 1980 4290 1850 2250 2692 / 3112 2100 2500
FKH-713P 264 4 25412 4" 4" 2706 5456 1850 2250 2067 1783 4150 2100 2500
FKH-713G 311 5.5 33882 4" 4" 2838 5588 1850 2250 2067 1783 4150 2100 2500
FKH-722P 227 4 23294 4" 4" 2376 5038 1850 2610 3192 / 3692 2100 2860
FKH-722G 278 5.5 33882 4" 4" 2508 5170 1850 2610 3192 / 3692 2100 2860
FKH-724P 326 5.5 36529 5" 5" 3300 6490 1850 2610 2551 1783 4634 2100 2860
FKH-724G 370 7.5 41765 5" 5" 3498 6710 1850 2610 2551 1783 4634 2100 2860
FKH-732P 308 5.5 36647 5" 5" 2684 5632 1850 2896 3192 / 3692 2100 3150
FKH-732G 333 7.5 41765 5" 5" 2882 5830 1850 2896 3192 / 3692 2100 3150
FKH-734P 403 7.5 44471 6" 6" 3740 7260 1850 2896 2551 1783 4634 2100 3150
FKH-734G 447 10 50824 6" 6" 4004 7590 1850 2896 2551 1783 4634 2100 3150
FKH-742P 458 7.5 46176 6" 6" 3520 7920 2250 3540 3192 / 3692 2500 3800
FKH-742G 502 10 55882 6" 6" 3850 8184 2250 3540 3192 / 3692 2500 3800
FKH-744P 645 10 65882 8" 8" 4840 10120 2250 3540 2551 1783 4634 2500 3800
FKH-744G 700 15 78824 8" 8" 5324 10560 2250 3540 2551 1783 4634 2500 3800

1. Model code: FKN-2931P
F: exhaust type; K: open; C: lateral air inlet;
711: machine code; P: noise grade.

2. Reference conditions
cooling medium: clean water; dry bulb temperature: 31.5 °C;
wet bulb temperature: 28 °C; atmospheric pressure: 99.4KPa;
water-side fouling coefficient: 0.086m² °C /kW.

3. Water in the catch basin could flow by itself as long as you enlarge the outlet aperture.


The FKH Double Box Cooling Tower with Sidestream Filtration
Model Flow 98.6-89.6 °C
(GPM)
Fan Inlet (In) Outlet (In) Shipping Weight
(lbs)
Operating Weight
(lbs)
Dimensions Basic Dimensions

Power
(HP)
Airflow Rate
(CFM)
L
(mm)
W
(mm)
h1
(mm)
h2
(mm)
H
(mm)
A
(mm)
B
(mm)
FKH-2711P 330 3×2 37176 5" 5" 3850 8470 3620 2250 2692 / 3112 3870 2500
FKH-2711G 410 4×2 46588 5" 5" 4070 8690 3620 2250 2692 / 3112 3870 2500
FKH-2713P 527 4×2 50824 6" 6" 5588 11088 3620 2250 2067 1783 4150 3870 2500
FKH-2713G 623 5.5×2 67765 6" 6" 5852 11352 3620 2250 2067 1783 4150 3870 2500
FKH-2722P 535 4×2 46588 6" 6" 4862 10186 3620 2610 3192 / 3692 3870 2860
FKH-2722G 586 5.5×2 67765 6" 6" 5126 10450 3620 2610 3192 / 3692 3870 2860
FKH-2724P 733 5.5×2 73059 8" 8" 6776 13156 3620 2610 2551 1783 4634 3870 2860
FKH-2724G 791 7.5×2 83529 8" 8" 7172 13596 3620 2610 2551 1783 4634 3870 2860
FKH-2732P 619 5.5×2 73294 6" 6" 5478 11374 3620 2896 3192 / 3692 3870 3150
FKH-2732G 670 7.5×2 83647 6" 6" 5874 11770 3620 2896 3192 / 3692 3870 3150
FKH-2734P 817 7.5×2 88941 8" 8" 7656 14696 3620 2896 2551 1783 4634 3870 3150
FKH-2734G 897 10×2 101647 8" 8" 8184 15356 3620 2896 2551 1783 4634 3870 3150
FKH-2742P 916 7.5×2 92353 8" 8" 7150 15950 4580 3540 3192 / 3692 4830 3800
FKH-2742G 1004 10×2 111765 8" 8" 7810 16478 4580 3540 3192 / 3692 4830 3800
FKH-2744P 1289 10×2 131765 10" 10" 9856 20416 4580 3540 2551 1783 4634 4830 3800
FKH-2744G 1399 15×2 157647 10" 10" 10824 21296 4580 3540 2551 1783 4634 4830 3800

1. Model code: FKN-2931P
F: exhaust type; K: open; C: lateral air inlet;
2: module number; 711: machine code; P: noise grade.

2. Reference conditions
cooling medium: clean water; dry bulb temperature: 31.5 °C;
wet bulb temperature: 28 °C; atmospheric pressure: 99.4KPa;
water-side fouling coefficient: 0.086m² °C /kW.

3. Water in the catch basin could flow by itself as long as you enlarge the outlet aperture.


FKH Triple-box Cooling Tower with Sidestream Filtration
Model Flow 98.6-89.6℃
(GPM)
Fan Inlet (In) Outlet (In) Shipping Weight
(lbs)
Operating Weight
(lbs)
Dimensions Basic Dimensions

Power
(HP)
Airflow Rate
(CFM)
L
(mm)
W
(mm)
h1
(mm)
h2
(mm)
H
(mm)
A
(mm)
B
(mm)

FKH-3711P 495 3×3 55765 6" 6" 5720 12650 5390 2250 2692 / 3112 5650 2500
FKH-3711G 615 4×3 69882 6" 6" 6050 12980 5390 2250 2692 / 3112 5650 2500
FKH-3713P 791 4×3 76235 8" 8" 8294 16544 5390 2250 2067 1783 4150 5650 2500
FKH-3713G 934 5.5×3 101647 8" 8" 8690 16940 5390 2250 2067 1783 4150 5650 2500
FKH-3722P 681 4×3 69882 8" 8" 7238 15224 5390 2610 3192 / 3692 5650 2860
FKH-3722G 835 5.5×3 101647 8" 8" 7634 15620 5390 2610 3192 / 3692 5650 2860
FKH-3724P 978 5.5×3 109588 8" 8" 10076 19646 5390 2610 2551 1783 4634 5650 2860
FKH-3724G 1110 7.5×3 125294 8" 8" 10670 20306 5390 2610 2551 1783 4634 5650 2860
FKH-3732P 923 5.5×3 109941 8" 8" 8162 17006 5390 2896 3192 / 3692 5650 3150
FKH-3732G 1000 7.5×3 125294 8" 8" 8756 17600 5390 2896 3192 / 3692 5650 3150
FKH-3734P 1209 7.5×3 133412 10" 10" 11396 21956 5390 2896 2551 1783 4634 5650 3150
FKH-3734G 1341 10×3 152471 10" 10" 12188 22946 5390 2896 2551 1783 4634 5650 3150
FKH-4722P 908 4×4 93176 6"(2) 6"(2) 9614 20262 7160 2610 3192 / 3692 7410 2860
FKH-4722G 1114 5.5×4 135529 6"(2) 6"(2) 10142 20790 7160 2610 3192 / 3692 7410 2860
FKH-4724P 1304 5.5×4 146118 8"(2) 8"(2) 13376 26136 7160 2610 2551 1783 4634 7410 2860
FKH-4724G 1480 7.5×4 167059 8"(2) 8"(2) 14168 27016 7160 2610 2551 1783 4634 7410 2860
FKH-4732P 1231 5.5×4 146588 6"(2) 6"(2) 10846 22638 7160 2896 3192 / 3692 7410 3150
FKH-4732G 1333 7.5×4 167059 6"(2) 6"(2) 11638 23430 7160 2896 3192 / 3692 7410 3150
FKH-4734P 1612 7.5×4 177882 8"(2) 8"(2) 15136 29216 7160 2896 2551 1783 4634 7410 3150
FKH-4734G 1788 10×4 203294 8"(2) 8"(2) 16192 30536 7160 2896 2551 1783 4634 7410 3150

1. Model code: FKN-2931P
F: exhaust type; K: open; C: lateral air inlet;
3: module number; 711: machine code; P: noise grade.

2. Reference conditions
cooling medium: clean water; dry bulb temperature: 31.5 °C;
wet bulb temperature: 28 °C; atmospheric pressure: 99.4KPa;
water-side fouling coefficient: 0.086m² °C /kW.

3. Water in the catch basin could flow by itself as long as you enlarge the outlet aperture.


FKH Double-module Cooling Tower with Sidestream Filtration
As the figure shows, any type of this FKC cooling tower could match with other cooling tower, forming a double-module cooling tower. Data of such double-module or multi-module cooling tower is shown by the below table. And those of other multi-module cooling equipment could be deducted by this analogy.

Model Flow 98.6-
89.6℃
(GPM)
Fan Inlet (In) (In) Shipping Weight
(lbs)
Operating Weight
(lbs)
Appearance size Foundation size

Power
(HP)
Airflow Rate
(CFM)
L
(mm)
W
(mm)
h1
(mm)
h2
(mm)
H
(mm)
A
(mm)
B
(mm)
Data of the above mentioned cooling tower are omitted here
FKH-2734G-Ⅱ 1795 11×4 203294 8"×2 8"×2 16386 30800 3620 5792 2551 1783 4634 3870 6300
FKH-2742P-Ⅱ 1832 7.5×4 184706 8"×2 8"×2 14300 31900 4580 7080 3192 / 3692 4830 7600
FKH-3724G-Ⅱ 2220 7.5×6 250588 8"×2 8"×2 21340 40480 5390 5220 2551 1783 4634 5650 5720
FKH-3732P-Ⅱ 1846 5.5×6 220000 8"×2 8"×2 16324 34012 5390 5792 3192 / 3692 5650 6300
FKH-4724G-Ⅱ 2960 7.5×8 334118 8"×4 8"×4 28336 53900 7160 5220 2551 1783 4634 7410 5720
FKH-4732P-Ⅱ 2462 5.5×8 292941 6"×4 6"×4 21692 45276 7160 5792 3192 / 3692 7410 6300
Data of the following cooling tower are omitted here
Please be noted that: there is a suffix "II" in the machine code of the double-module cooling equipment, which implies that the equipment is a combined product. For example, the double module combination cooling tower of the FKH-2734 is named FKH-2734-Ⅱ. All the cooling towers, no mater it is single-box, double-box, three-box, or four box, could be combined with other counterparts to form a double-module or quadric-module cooling equipment.
Related products