Closed Loop Water Source Heat Pump, 2.6kW-40kW

Closed Loop Water Source Heat Pump, 2.6kW-40kW
Request a Quote

This product has been discontinued and removed from our shelves.

Application

The closed loop water source heat pump is especially suitable for the construction of new buildings or the redevelopment of existing structures.

1. As for new buildings, the cooling water main pipe and preserved branch pipe of loop water source heat pump can be first installed. Developers can allocate, purchase and install heat pumps before residences move in the house according to the actual utilization, thus reducing the burden of initial investment.
2. Special heat preservation cooling water pipes are not needed. It has a wide application in supermarkets, hospitals, office buildings, hotels, complex buildings, commercial buildings and so forth.

Parameters of closed loop water source heat pump

Water-water type closed loop water source heat pump

Model SS/SR 75 100 120 145 200 250
Nominal cooling capacity kw 7.5 10 12 14.5 19.5 25
Nominal heating capacity kw 8.9 12 15 17.5 23 29
Nominal cooling input power kw 1.9 2.52 3 3.65 4.8 6.2
Nominal heating input power kw 2.1 2.9 3.6 4.1 5.4 6.8
Nominal cooling running current A 8.6 11.5 13.6 6.9 9.1 11.8
Nominal heating running current A 9.5 13.2 16.4 8 10.5 13.3
Power 220V/1N/50Hz 380v/3N/50Hz
Type of compressor Rotary type Scroll type
No. of compressor unit 1
Type of refrigerant R22
Dimension(L×W×H) mm 935×435×525 970×436×550 884×473×812 884×473×812 884×473×812 1415×820×1060
Water flow at the heat source side m3/h 1.6 2.2 2.6 3.1 4.2 5.4
Tube dimension at the heat source side DN 25 32
Water resistance at the heat source kpa 28 28 31 34 34 45
Water flow at the operation side m3/h 1.29 1.72 2.06 2.49 3.3.5 4.3
Tube dimension at the operation side DN 25 32
Water resistance at operation side Kpa 26 27 29 33 33 33
Noise DB(A) 50 54 54 56 58 58
Weight kg 85 100 105 120 150 250
Power line diameter options 3×2.5 3×4 3×4 2×1.5 3×4 2×1.5

Holistic underground closed loop heat pump units

Models SFG/SFGR 26 35 45 58 72
Nominal cooling capacity kw 2.6 3.5 4.5 5.8 7.2
Nominal heating capacity kw 2.48 3.2 4.1 5.3 6.6
Nominal cooling input power kw 0.6 0.78 1.06 1.38 1.72
Nominal heating input power kw 0.58 0.76 1.01 1.26 1.59
Nominal cooling running current A 2.9 3.7 5.1 6.6 8.2
Nominal heating running current A 2.8 3.6 4.8 6 7.6
Power 220V/1N/50Hz
Type of compressor Rotary type
Compressor Qty. Unit 1
Dimension(L×W×H) mm 1060×500×360 1050×500×420 1100×560×486
Weight kg 60 65 75 85 100
Water volume m3/h 0.55 0.74 0.96 1.23 1.53
Cooling pipe diameter DN 20 25
Condensate pipe diameter DN 20
Refrigerant charging volume kg 0.6 0.8 0 1.1 1.25

Split underground closed loop heat pump units

Models Indoor unit SFRFN 26 35 45 58 72 86 105 126 146
Outdoor unit SFRFW 26 35 45 58 72 86 105 126 146
Nominal cooling capacity kw 2.6 3.5 4.5 5.8 7.2 8.6 10.5 12.6 14.6
Nominal heating capacity kw 3 3.95 5.1 6.48 8.1 9.4 11.4 13.6 15.8
Nominal cooling input power KW 0.59 0.82 1.02 1.35 1.66 1.94 2.51 3.02 3.47
Nominal heating input power KW 0.63 0.85 1.1 1.45 1.74 2.03 2.71 3.24 3.7
Nominal cooling running current A 2.7 3.9 4.9 6.5 7.8 9.3 3.9 4.7 5.4
Nominal heating running current A 3 4 5.2 6.9 8.2 9.7 4.2 5 5.7
Type of compressor Rotary type Scroll type
Compressor Qty. Unit 1 1
Power 220V/1N/50Hz 380V/3N/50Hz
Circulating air volume of indoor unit m3/h 500 700 910 1190 1480 1760 2150 2570 3010
Excess pressure Pa 12(8) 20(12) 30(20) 50(30)
Sound level Indoor unit dB(A) 35 35 37 37 40 41 42 42 42
Outdoor unit dB(A) 30 31 32 32 35 36 36 38 38
Dimension mm 855 1005 1125 1355 1605 1750 2006 2065 2065
(L×W×H) Indoor unit mm 475 475 475 475 475 475 475 490 490
mm 237 237 237 237 237 237 237 287 287
mm 550 550 590 550 635 635 695 720 720
Outdoor unit mm 430 430 430 490 520 520 520 580 580
mm 385 385 385 420 510 510 535 535 535
Indoor unit kg 18 22 26 30 34 36 40 50 55
Weight Outdoor unit kg 34 35 40 48 66 68 90 90 100
Water flow m3/h 0.55 0.74 0.95 1.23 1.52 1.81 2.24 2.69 3.11
Water resistance kpa 18 22 30 35 35 35 35 38 38
Joint pipe dimension(Outer diameter×tube thickness) Fluid pipe mm Φ6×0.75 Φ9.52×0.75 Φ12.7×0.75
Air pipe mm Φ9.52×0.75 Φ12.7×0.75 Φ16×1.0 Φ19×1.0
Cooling water tube diameter DN 20 25 32
Condensate water tube diameter DN 20
Charging quantity of refrigerant kg 0.65 0.84 0.95 1.1 1.5 1.8 2.1 2.3 2.8
Features of closed loop water source heat pump
  • High efficiency and energy saving. The compressor adopts rotary type or scroll type. Cooling water heat exchanger adopts heat exchanging copper tubes. The COP value of water source air conditioner is 4.2-5.5, minimizing power consumption.
  • A centralized primary machine room is not needed. The closed loop water source heat pump central air conditioning system is composed of several small systems. Each room is an independent cooling systems. There is no need to set up machine rooms and pump rooms independently.
  • The adoption of modular units prevents the whole system from being affected by the breakdown of one unit.
  • Convenient billing system. Then the air conditioning system is applied for rental properties such as apartments, office buildings and shops, each user unit can independently be equipped with an electric meter and thus charged independently.