6-20kW Induction Central Heating Boiler

6-20kW Induction Central Heating Boiler
6-20kW Induction Central Heating Boiler
6-20kW Induction Central Heating Boiler
6-20kW Induction Central Heating Boiler
6-20kW Induction Central Heating Boiler
6-20kW Induction Central Heating Boiler
Request a Quote

Heating area: 50-220m²

Features
  • No electricity leakage;
  • Energy saving;
  • Multiple protection;
  • No fouling;
  • Intelligent control;
  • Easy to install;
  • Low installation cost;
Send
Parameter
Open type
Model Unit
BYD-C6DGS2-S
BYD-C8DGS2-S
BYD-C10DGS2-S
BYD-C10SGS2-S
BYD-C12DGS2-S
BYD-C15SGS2-S
BYD-C20SGS2-S
Rated power kW 6 8 10 10 12 15 20
Voltage/Frequency V/Hz 220/50-60 220/50-60 220/50-60 380/50-60 380/50-60 380/50-60 380/50-60
Cross section area of power cable mm² ≥6 ≥10 ≥10 ≥6 ≥6 ≥6 ≥10
Max. pressure of heating Mpa 0.2-0.4 0.2-0.4 0.2-0.4 0.2-0.4 0.2-0.4 0.2-0.4 0.2-0.4
Min. flow of pump L/min 12 16 20 20 25 30 35
Dimensions mm 600*400*175 600*400*175 600*400*175 600*400*175 600*400*175 675*420*260 675*420*260
Inlet/outlet connection DN 20/25 20/25 20/25 20/25 20/25 32 32
Heating area 50-70 70-90 80-120 80-120 100-140 140-170 180-220
Closed type
Model Unit
BYD-C6DGS4-S
BYD-C8DGS4-S
BYD-C10DGS4-S
BYD-C10SGS4-S
BYD-C12SGS4-S
Rated power kW 6 8 10 10 12
Voltage/Frequency V/Hz 220/50-60 220/50-60 220/50-60 380/50-60 380/50-60
Cross section area of power cable mm² ≥6 ≥10 ≥10 ≥6 ≥6
Max. pressure of heating Mpa 0.2-0.4 0.2-0.4 0.2-0.4 0.2-0.4 0.2-0.4
Min. flow of pump L/min 12 16 20 20 25
Dimensions mm 675*420*260 675*420*260 675*420*260 675*420*260 675*420*260
Inlet/outlet connection DN 20 20 20 20 20
Heating area 50-70 70-90 80-120 80-120 100-140
Dimensioning
Features

Energy Saving
When the indoor temperature exceeds the pre-set value, the central heating boiler will be automatically turned off, thus efficiently saving more than 30% energy. And it can save energy by 20% in comparison with traditional boilers that use resistance heating method.

Constant Temperature and Comfortable Space
Water temperature can be controlled within a range of 5~90ºC, and the precision of temperature control can reach ±1ºC, providing a comfortable atmosphere for your space. Unlike air conditioning equipment, induction heating does not create an ideal environment for bacteria to grow.

No Noise
In contrast to central heating boilers using air cooling method, water cooled heating boilers are more quiet and unobtrusive.

Safe Operation
Utilizing induction heating achieves separation of electricity and water, providing a safer operation. Besides, multiple protection functions such as antifreeze protection, electricity leakage protection, short circuit protection, phase loss protection, overheating protection, overcurrent protection, overvoltage protection, undervoltage protection, self-inspection protection are equipped. Safe usage is guaranteed for 10 years.

Intelligent Control
Our induction central heating boilers can be WIFI remotely controlled by smart phones.

Easy to Maintain
Induction heating do not constitute the condition of fouling, eliminating the need for fouling removing treatment.

Installation
  • Installation of Wall Mounted Induction Boiler (open type)
  • Installation of Wall Mounted Induction Boiler (closed type)
FAQ

Please Contact Our Customer Service before Make a Purchase

  • About Choosing Appropriate Power

    Choosing a suitable boiler based on your actual heating area
    For low-energy buildings, 60~80W/m² boilers are suitable;
    For general buildings, 80~100W/m² boilers are suitable;
    For villas and bungalows, 100~150W/m² boilers are suitable;
    For those buildings where sealing performance is not well and room height is greater than 2.7m or people frequently enter, the building heat load is correspondingly increased and the power of central heating boiler should be higher.

  • About Installation Conditions

    What are installation conditions
    Take a 15kW induction central heating boiler as an example:
    The cross section are of main power cable should not be less than 6mm3, main switch 32~45A, voltage 380V/50, minimum water flow of pump is 25L/min, the water pump needs to be selected according to building height.

  • About Accessories

    What accessories are required
    Since every installation site of customer is different, so that various accessories are required. We only provide central heating boilers, other accessories such as pump valve, piping and union connectors need to be purchased by customers.

  • About Connections For Heating

    What are applicable connections for heating
    BIYDA’s induction central heating boilers can be flexibly connected to floor heating system, radiator, hot water storage tank, fan coil unit (FCU), etc.

  • About Installation Service

    Our products can be installed by our authorized local dealers. We also accept advance reservation, and we designate engineers to offer installation service and technical guidance on site.

  • About Logistics

    Shipping time and logistic distribution
    We promise to ship our ready-to-ship products within 24 hours, and ship our made-to-order products within 7-10 days. And the logistics service is based on customers’ requirements.

  • About Service Life

    How long is this product’s service life
    BIYDA’s induction central heating boiler adopts high-frequency induction coil and industrial grade inverter, all key parts are made of imported high grade materials, its service life can reach 15 years or more.

Related products
Send Message
Other Products
Inquiry
Inquiry