Meters and Measurement Devices for Exact Consumption Data Acquisition
Harmonic monitoring power meters are a three-phase four-wire multifunction power meter. With the use of a modern digitized information processed chip and high precision electric energy measuring chip, this power meter will accurately measure all the commonly used electric power parameters in a three-phase power system, including three-phase-current, active power, apparent power, line frequency, voltage unbalance, voltage harmonic, current harmonic, zero-sequence current, and other parameters.
Basic Controls’ harmonic monitoring power meter has an RS85 digital communication interface and electric energy pulse output. With its high cost performance, it easily replaces regular measuring indicators, power meters, and related auxiliary units. can take the place of regular measuring indicator, power meter and the related auxiliary units.
Application
As a smart digital front-end acquisition unit in power system, harmonic monitoring power meters are widely used in a variety of control systems, SCADA systems, energy management systems, power transformation automation, distribution network automation, community electrical power monitoring and controlling, industrial automation, intelligent building, intelligent distribution board and switch cabinets.
Moreover, harmonic monitoring power meters are field programmable to set the input parameters. Group-net communication with PLC, frequency converter and industrial control computer is accessible.
Measuring capability- Total Harmonics Distortion: UA、UB、UC phase total voltage harmonics distortion; IA、IB、IC phase total current harmonics distortion
- Electrical energy: import/export active electrical energy; total active electrical energy (import export); import/export reactive electrical energy; total reactive electrical energy (import export)
- Voltage:A-phase voltage, B-phase voltage, C-phase voltage, AB/BC/CA three-phase voltage
- Current:A-phase current, B-phase current, C-phase current
- Power: total active power, A-phase active power, B-phase active power, C-phase active power, total reactive power, A-phase reactive power, B-phase reactive power, C-phase reactive power, total apparent power, A-phase apparent power, B-phase apparent power, C-phase apparent power, total power factor, A-phase power factor, B-phase power factor, C-phase power factor, line frequency
Panel size | 96×96×90mm | |
Hole size | 91×91mm | |
Installation | Insertion | |
Communication interface | RS485 | |
Data type | Floating point | |
Communication protocol | MODBUS-RTU | |
Communication baud rate | Factory default: 9600bpS (4800bps-9600bpsoptional) | |
Operating power supply | AC220V | |
Power consumption | 5VA | |
Input measuring voltage | Rated value | AC100 or AC400 |
Overload | Continuous: 1.2 times; instaneous: 10 times/10s | |
Power consumption | Single-phase: 1VA | |
Impedance | 500KΩ | |
Accuracy | RMS measurement, accuracy class 0.5 | |
Input measuring current | Rated value | AC1A or AC5A |
Overload | Continuous: 1.2 times; instaneous: 10 times/10s | |
Power consumption | Single-phase: 0.4VA | |
Impedance | 2MΩ | |
Accuracy | RMS measurement, accuracy class 0.5 | |
Two electric energy pulse outputs | 3200imp/kwh | |
Harmonics | Total content of 21th harmonic | |
Display | LCD, programmable, circulating, switchable | |
Withstand voltage | input/power supply>2KV, input/output>2KV, power supply/output>2KV | |
Insulation | 50MΩ | |
Working environment | -10~55℃ | |
Storage environment | -20~75℃ |
① Outline size ② Hole size