IPHT Series Anaerobic Temperature Test Chamber
Request a Quote
Temperature chamber with a non-oxidizing gas intake structure for high temperature testing under low oxygen conditions
Creating a stable low-oxygen environment is necessary for certain high-temperature processes, especially when working with materials prone to oxidation. This test chamber combines precise temperature control with a built-in gas supply system that introduces CO₂, nitrogen, or other inert gases to lower oxygen concentration during testing and heat treatment. By maintaining reduced oxygen levels, it helps protect sensitive samples, improve reliability of test results, and minimize the risk of surface damage.
Features
- Integrated gas inlet system for controlled atmosphere adjustment
- Consistent low-oxygen environment that slows down oxidation and safeguards components
Standard Configuration
- 2 sets of specimen racks
- 1 vent port
- 1 terminal block for controlling specimen power supply
Technical Parameters
Model | | | |||||||
101 | 201 | 301 | 401 | 101 | 201 | 301 | 401 | ||
Chamber volume (L) | 91 | 216 | 512 | 1000 | 91 | 216 | 512 | 1000 | |
Temperature range | (Ambient temperature 20/30*)℃~ 200℃ | (Ambient temperature 20/30*)℃~ 300℃ | |||||||
Temperature fluctuation | ≤100℃ | 0.4℃ | 0.4℃ | 0.4℃ | 0.4℃ | ||||
≤200℃ | 0.8℃ | 0.8℃ | |||||||
≤300℃ | —— | 0.8℃ | 1.2℃ | ||||||
Temperature deviation | ≤100℃ | ±1.5℃ | ±2.0℃ | ±1.5℃ | ±1.5℃ | ±2.0℃ | |||
≤200℃ | ±2.0℃ | ±2.0℃ | ±2.0℃ | ||||||
≤300℃ | —— | ±3.0℃ | ±4.0℃ | ||||||
Temperature rise rate | ≤40min | ≤60min | ≤80min | ≤60min | ≤70min | ≤80min | |||
Internal dimensions (mm) | W | 450 | 600 | 800 | 1000 | 450 | 600 | 800 | 1000 |
H | 450 | 600 | 800 | 1000 | 450 | 600 | 800 | 1000 | |
D | 450 | 600 | 800 | 1000 | 450 | 600 | 800 | 1000 | |
External dimensions (without protrusion) (mm) | W | 1040 | 1190 | 1500 | 1730 | 1040 | 1190 | 1500 | 1730 |
H | 820 | 970 | 1210 | 1480 | 820 | 970 | 1210 | 1480 | |
D | 635 | 785 | 1065 | 1275 | 635 | 785 | 1065 | 1275 | |
Power supply | 220V | 380V | 220V | 380V | |||||
(single phase protective grounding wire) | (three phase four wire protective grounding wire) | (single phase protective grounding wire) | (three phase four wire protective grounding wire) |
Performance measured at 25 °C ambient temperature, with the chamber empty and no air exchange during operation.
Related Manufacturies
Leave Message
Similar Manufacturies and Parts
Manufacturer Advertising
More
Similar Manufacturies and Parts
Videos