TS Series Two-Zone Thermal Shock Test Chamber
Request a Quote
Environmental chamber for evaluating product reliability through rapid transitions between hot and cold temperature zones
A two-zone thermal shock chamber transfers samples between separate hot and cold sections to create immediate temperature changes. This method is essential for uncovering hidden defects, validating product durability, and ensuring components can tolerate rapid thermal stress during use.
Common Test Applications
- High-temperature exposure
- Low-temperature performance evaluation
- Controlled thermal cycling
- Instant thermal shock testing
Standard Configuration
- Two sets of specimen baskets
- Hour meter
- 1 observation window (insulating glass with transparent heating film)
- 6 caster wheels (including leveling feet)
- 1 sample power control terminal
1 RS-485 communication port
1 RJ-45 Ethernet port - USB port
Technical Parameters
Model | | | | ||
Chamber volume (L) | Approx. 120 | Approx. 300 | |||
Test system | 2-zone,basket moving up and down driven by motor and screw | ||||
Performance | High temperature zone | Temperature range | 60℃~ 220℃ | ||
Temperature rise rate | ≥10℃/min | ||||
Low temperature zone | Temperature range | -80℃~ 70℃ | |||
Temperature rise rate | ≥2℃/min | ≥1.5℃/min | |||
Temperature drop rate | ≥4℃/min | ≥5℃/min | |||
Test area (basket) | High-temperature exposure range | 60℃~ 200℃ | |||
Low-temperature exposure range | -70℃~ 70℃ | ||||
Temperature fluctuation | 1℃ | ||||
Temperature deviation | ±2℃ (≤150℃),±3℃ (>150℃) | ||||
Temperature recovery performance | Temperature recovery time | ≤5min | |||
Basket transfer time | ≤10sec | ||||
Test requirements | High temperature exposure: 150℃ 30min Low temperature exposure:-55℃ 30min Specimen weight:3kg (plastic mold IC in two sample baskets) | High temperature exposure: 150℃ 30min Low temperature exposure:-55℃ 30min Specimen weight:10kg (plastic mold IC in two sample baskets) | |||
Conditions | Sensor position:Near the center of the test area. Cooling water temperature: 25°C (only for water-cooled models). Power supply voltage:According to specified voltage requirements. | ||||
Internal dimensions (mm) | W470×H410×D650 | W470×H410×D650 | W770×H610×D650 | ||
External dimensions (without protrusion) (mm) | W1250×H2607×D2900 | W1000×H2607×D2530 | W1360×H3074×D3135 | ||
Rated power (kW) | 16.5 | 15 | 35 | ||
Condensing method | Air-cooled | Water-cooled |
For air-cooled models, the stated performance is based on ambient conditions of 25 °C with relative humidity ≤85%, measured with no test specimens inside the chamber. For water-cooled models, performance is based on ambient temperature between 15 °C and 35 °C, relative humidity ≤85%, and cooling water temperature ≤ 28 °C, also measured without test specimens inside.