Modular Air Cooled Chiller (Scroll Compressor)

Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Modular Air Cooled Chiller (Scroll Compressor)
Request a Quote
  • Modular Air Cooled Chiller(Single-module)
  • Modular Air Cooled Chiller(Multi-module)
R2245.0÷130.0kW
R410A45.0÷76.0kW
R134A30.0÷55.0kW

Structure of Modular Air Cooled Chiller
1. Of a thin design, this modular air cooled chiller (scroll compressor) could be installed in various places such as balcony, roof, garden and so forth. At the same time, its framework and metal panels are respectively made of aluminum alloy and stainless steels, highly resistant to corrosions;

2. Instead of the traditional split structure which makes the installation more complex, this modular air cooled aircon enjoys a packaged structure, much easier to install and more pleasant for eyes;

3. This multifunctional chilling unit could be added with an expansion tank as long as you require. Therefore, it could be put into use instantly after being connected with water pipes and power supply.

Features of Modular Air Cooled Chiller
1. This split air cooled chiller is one of the classic equipment we developed in earlier period;

2. It is equipped with cold rolled metal panels which, treated by electrostatic spray, is highly resistant to corrosion and rust;

3. Of a modular structure, this stroll type central air conditioner could be composed of several same modules to satisfy customers' cooling needs;

4. This unit enjoys multiple functions which mainly include single cooling, single heating, cooling plus heat recovery, heating plus heat recovery and heat recovery. Especially, the heat recovery function could provide water for daily life which is different from the hot water for heat pump of aircon;

5. The standard unit of this modular chiller which enjoys five functions could provide total heat recovery function and partial heat recovery function;

6.Its controller could enable users to control the unit in a convenient and reliable way;

7. Equipped with a low-noise fan, this air cooled chiller could operate in a quite way;

8. The wiring controller of this modular A/C equipment makes remote control available for users;

9. It is designed with several effective protective devices such as those for extremely high/low pressure, overheat, oil temp, lack-phase and overload of compressor, this ac equipment is safe to operate;

10. We could provide integrally assembled modular air cooled chiller to customers. Of course, customers could come to the site to conduct subpackage.

Technical Specifications of Modular Air Cooled Chiller-R22
ModelHACHW- 45HACHW- 50HACHW- 70HACHW- 76HACHW- 100HACHW- 110HACHW- 130
Nominal cooling capacity kW45507076100110130
kcal/h387004300060200653608600094600111800
Nominal heating capacitykW47527379104114135
kcal/h404204472062780679408944098040116100
PowerAC380V-3PH-50Hz
Rated currentA26284043586374
Control modeAutomatic control
Refrigerant R22
Throttle modeThermal expansion valve
Protective measuresProtective devices for extremely high/low pressure, overheat, oil temp, lack-phase and overload of compressor
Compressor TypeFlexible scroll compressor
Quantity Unit2222334
Rated power kW6.6x27.3x210.3x211.2x29,9x310.7x39.48x4
Fan motorTypeAxial fan motor
Quantity Unit2222222
Power kW0.55x20.55x20.75x20.75x21,5x21,5x21,8x2
Heat exchangerTypeShell and tube heat exchanger
Waterflow m3/h7.748.612.0413.0717.218.9222.35
Water drop kPa≤ 75
Water pipe sizeDN50DN65DN80
NoisedB(A)68707070707075
Dimensions Length mm85010001300
Width mm170022002500
Heightmm180022302230
Weightkg62067075080095010001300

Please note that
1. Cooling condition: chilled water inlet temperature: 12 ℃, outlet temperature: 7 ℃,
entering air DB: 35 ℃;
2. Heating condition: heated water inlet temperature: 40 ℃, outlet temperature: 45 ℃;
entering air DB: 7 ℃, WB: 6 ℃;
3. Operating Temperature Ranges: -5 ℃ ~40 ℃, temperature limit: -10 ℃ ~43 ℃;
4. Unit input power= compressor input power fan input power pump input power;
5. Mortification of any datum in the above table will not be informed;
6. This equipment could contain 10 modules at best and adopt multiple types of compressors.

Technical Specifications of Modular Air Cooled Chiller-R134A
ModelHACHW-30-MHACHW-36-MHACHW-50-MHACHW-55T-M
Nominal cooling capacitykW30365055
kcal/h25800309604300047300
Nominal heating capacitykW31375156
kcal/h26660318204386048160
PowerAC380V-3PH-50Hz
Rated currentA21263640
Control modeAutomatic control
Refrigerant R134a
Throttle modeThermal expansion valve
Protective devices Protective devices for extremely high/low pressure, overheat, oil temp, lack-phase and overload of compressor
Compressor TypeFlexible scroll compressor
QuantityUnit 2222
Rated power kW7.8x210x210.8x29,7x3
Fan motor TypeAxial fan
Quantity Unit 2222
Motor powerkW0.55x20.85x20.85x21.1x2
Heat exchangerTypeShell and tube heat exchanger
Waterflowm3/h5.166.198.69.46
Water drop kPa≤ 75
Water pipe sizeDN40DN50
Noise dB(A)68707072
DimensionsLength mm10001300
Widthmm22002500
Heightmm2050 180(fan cover )2200
Weightkg7208008301300

Please note that
1. Cooling condition: chilled water inlet temperature: 12 ℃, outlet temperature: 7 ℃,
entering air DB: 35 ℃;
2. Heating condition: heated water inlet temperature: 40 ℃, outlet temperature: 45 ℃;
entering air DB: 7 ℃, WB: 6 ℃;
3. Operating Temperature Ranges: -5 ℃ ~40 ℃, temperature limit: -10 ℃ ~43 ℃;
4. Unit input power= compressor input power fan input power pump input power;
5. Mortification of any datum in the above table will not be informed.

Technical Specifications of Modular Air Cooled Chiller-R410A
ModelHACHW-45-ZHACHW-50-ZHACHW-70-ZHACHW-76-Z
Nominal cooling capacitykW45507076
kcal/h38700430006020065360
Nominal heating capacitykW47527379
kcal/h40420447206278067940
PowerAC380V-3PH-50Hz
Rated currentA28324448
Control modeAutomatic control
Refrigerant R410a
Throttle modeThermal expansion valve
Protective devices Protective devices for extremely high/low pressure, overheat, oil temp, lack-phase and overload of compressor
Compressor TypeFlexible scroll compressor
QuantityUnit 2222
Rated power kW7.4x28,3x211.6x213.4x2
Fan motor TypeAxial fan
QuantityUnit2222
Motor power kW0.55x20.55x20.75x20.75x2
Heat exchanger Type Shell and tube heat exchanger
Water flow m3/h7.748.612.0413.07
Water drop kPa≤ 75
Water pipe sizeDN50DN65
Noise dB(A)68707070
DimensionLengthmm8501000
Widthmm17002200
Heightmm18002230
Weightkg620670750800

Please note that
1. Cooling condition: chilled water inlet temperature: 12 ℃, outlet temperature: 7 ℃,
entering air DB: 35 ℃;
2. Heating condition: heated water inlet temperature: 40 ℃, outlet temperature: 45 ℃;
entering air DB: 7 ℃, WB: 6 ℃;
3. Operating Temperature Ranges: -5 ℃ ~ 40 ℃, temperature limit: -105 ℃ ~ 43 ℃;
4. Unit input power= compressor input power fan input power pump input power;
5. Mortification of any datum in the above table will not be informed;
6. This unit could be built in the same way of unit-R22.

Related Products
Related products
Send Message
Other Products
Inquiry
Inquiry